Service Note
Product
Description:
Service note no.
M5000
Modification to avoid E04 when warm
71210T057
Filename: SNo_T057.doc
Date: 01-03-2007
TC Electronic
Page 3 of 3
7. Solder a wire from IC6 pin 11 (lifted out) to IC7 pin 11 (lifted out).
8. Mount the CPU PCB again with the 2 screws and the 2 jack nuts.
9. Mount the 3 cables again.
10. Mount top and bottom cover.
About the schematics.
After this modification the signal called AS* is no longer connected to IC6 and IC7.
Instead the signal called RAS* is connected to IC6 and IC7.