Buffer Size

Buffer Size*

The buffer size can be set from 32 to 8192 samples.
The higher the buffer setting, the longer latency through
Digital Konnekt x32. You should only increase the buffer
size if you experience problems such a clicks and pops
in the sound. Note that clicks and pops in the sound may
also derive from clock problems. These should be
resolved first.

*

Setting the buffer size via the TC Near control panel
is relevant for the PC version only. On Mac
computers buffer size is set in the audio application.
For instance in Logic Pro go to: Audio/Hardware
drivers to set the buffer size.

System Clock

Clock Master

With the Clock Master parameter you select which of the
Konnekts in your setup units that should act as system
Clock Master. 

In a digital setup, it is important that all connected
devices run at the same sample rate. The Clock Master
device defines this sample rate, and distributes a digital
clock based on this sample rate to all devices in the
setup. There can be one, and only one clock master in a
digital setup, and you cannot select your computer here.
However, the Clock Master device may sync to an
external device. See “Sync Source” below.

Sync Source

The Sync Source parameter determines to which the
device the Clock Master should sync. The DICE II
FireWire chip provides excellent clock and in many
setups the “internal” option is the best choice. However,
you may sync to any digital device attached to the Digital
Konnekt x32 digital inputs and enjoy the outstanding
JetPLL jitter rejection technology also provided by the
DICE II.

Sample Rate

If Sync Source is set to “Internal”, the sample rate must
be set. The options are:

44.1 kHz
48 kHz
88.2 kHz
96 kHz
176.4 kHz
192 kHz

The sample rate is typically set by your host application.
If you e.g. play a 44.1 kHz project the sample rate
automatically shifts to 44.1 kHz. If you later load and play
a 48 kHz song, the sample rate shifts to 48 kHz. 
Though Konnekt receives information about the sample
rate it still provides the actual digital clock.

TC NEAR CONTROL PANEL

26

Summary of Contents for Digital Konnekt x32

Page 1: ...User s Manual EnglishVersion Digital Konnekt x32...

Page 2: ......

Page 3: ...ipment should be installed near the socket outlet and disconnection of the device should be easily accessible To completely disconnect from AC mains disconnect the power supply cord from the AC recept...

Page 4: ...ent from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help For Customers in Canada This Class B digital apparatus complies with Canadian ICES 00...

Page 5: ...ADAT routing 8 Firewire in 9 Firewire routing 9 Master Clock section 10 Setup Util 11 Scenes 12 Monitor 12 Rear Panel View 13 The integrator 14 SETUP EXAMPLES Example 1 Integrating external hardware...

Page 6: ......

Page 7: ...ignal handling Never before have these essential functions been incorporated in a single platform linking your entire fleet of digital devices to your DAW Make your favorite hardware the heart of your...

Page 8: ...STORE SCENE input signal HOLD TO UN LOCK 192kHz fs AES pro out 1 2 3 4 1 2 1 2 1 2 3 4 3 4 3 4 5 6 5 6 5 6 7 8 7 8 7 8 adat 1 8 adat 1 8 adat 1 8 P FORMAT CONVERTER PATCHBAY FIREWIRE IO digitalkonnekt...

Page 9: ...he ADAT section any selected sample rate conversion in the AES SPDIF TOS section is deselected AES SPDIF TOS Routing This is the routing section for the AES SPDIF and Toslink inputs Each input channel...

Page 10: ...clock rate aes spdif monitor LEDs dual wire XLR hold to select input security lock device adat monitor phones WCK in firewire INT 48k x2 x4 TOS IN 5 6 FRONT aes spdif clock master DS 9 16 LOCK SIG LOC...

Page 11: ...rewire channels 1 8 can be routed to AES SPDIF TOS outputs or to ADAT out Firewire channels 9 16 can be routed to AES SPDIF TOS outputs or to ADAT out Note that ADAT channels are handled in groups of...

Page 12: ...or LEDs dual wire XLR hold to select input security lock device adat WCK in firewire INT 48k x2 x4 SEL HO input signal HOLD TO UN LOCK 192kHz fs AES pro out 1 2 3 4 5 6 7 8 adat 1 8 P Master Clock In...

Page 13: ...monitor phones WCK in firewire INT 48k x2 x4 TOS IN 5 6 FRONT aes spdif clock master DS 9 16 LOCK SIG LOCK SIG LOCK SIG SEL 1 2 1 2 1 2 3 4 3 4 3 4 5 6 5 6 5 6 7 8 7 8 7 8 SRC HOLD TO STORE SCENE inpu...

Page 14: ...4 3 4 5 6 5 6 5 6 7 8 7 8 7 8 SRC HOLD TO STORE SCENE input signal HOLD TO UN LOCK 192kHz fs AES pro out 1 2 3 4 1 2 1 2 1 2 3 4 3 4 3 4 5 6 5 6 5 6 7 8 7 8 7 8 adat 1 8 adat 1 8 adat 1 8 P scenes s R...

Page 15: ...8 12345687 9872 OUT IN PROFESSIONAL AUDIO EQUIPMENT 100 240V AC 50 60Hz 15W THIS CLASS B DIGITAL DEVICE MEETS ALL REQUIREMENTS OF THE CANADIAN INTERFERENCE CAUSING EQUIPMENT REGULATIONS AND COMPLIES...

Page 16: ...DAW environment seamless It offers a plug in audio routing representation of your external digital effects processors and operates as a normal VST AU plug in The Integrator plug in can be inserted on...

Page 17: ...channel by default These are identified by the name of the first channel In the illustration on the previous page channel pair 9 10 is selected even though the label says fw ch 9 When inserting Integr...

Page 18: ...Integrator plug in allow integration of external digital effect devices with your DAW via Firewire Connections Reverb 4000 is connected via SPDIF coax 1 2 on Digital Konnekt x32 Finalizer 96K is conne...

Page 19: ...n aes spdif tos SRC SPDIF TOS FRONT aes spdif clock master LOCK SIG 1 2 3 4 5 6 7 8 Clock In the DAW you select External as clock source This allows you to use the Digital Konnekt x32 as master clock...

Page 20: ...in The Integrator plug in now opens For each external effects unit you want to integrate you make the same considerations as you are used to when setting up software plug in effects insert effects ar...

Page 21: ...firewire channel 7 8 by selecting fw ch 7 Finalizer 96K The Finalizer will typically be used for mastering Insert Integrator on you master stereo bus Select firewire channel 9 10 by selecting fw ch 9...

Page 22: ...5 6 5 6 7 8 7 8 7 8 adat 1 8 adat 1 8 adat 1 8 P KEYBOARD TOSLINK 3 4 SPDIF 5 6 SPDIF 7 8 FIREWIRE AES 1 2 CAT 5 SPDIF 1 2 In this example we show how to use the Digital Konnekt x32 as a conventional...

Page 23: ...te is set on your DAW master clock 44 1k clock rate aes spdif hold to select input adat WCK in firewire INT 48k x2 x4 SEL 3 4 1 2 5 6 7 8 aes spdif tos in aes spdif tos SRC SPDIF TOS FRONT aes spdif c...

Page 24: ...6 we send the signal to a broadcast section SETUP EXAMPLES 22 Example 3 PA setup FORMAT CONVERTER PATCHBAY FIREWIRE IO digitalkonnekt x32 3 4 3 4 3 4 1 2 1 2 1 2 5 6 5 6 5 6 7 8 7 8 7 8 adat adat ada...

Page 25: ...1 2 LED indicates that a signal is present on AES 1 2 Sample Rate conversion is activated on channels pair 1 2 AES channels 1 2 is routed to the master EQ via AES 3 4 out and also via 5 6 to broadcas...

Page 26: ...t the DVD player on the same channel pair as the Reverb 4000 In the AES SPDIF TOS input select section you will then have to decide which device that should be routed for the current application It is...

Page 27: ...it 3 4 1 2 5 6 7 8 aes spdif tos in aes spdif tos SRC SPDIF TOS FRONT aes spdif clock master LOCK SIG 1 2 3 4 5 6 7 8 Clock In Pro Tools you select AES EBU as clock source Digital Konnekt x32 then act...

Page 28: ...ased on this sample rate to all devices in the setup There can be one and only one clock master in a digital setup and you cannot select your computer here However the Clock Master device may sync to...

Page 29: ...electronic com Press Click here to download the latest version and download the full installer Run the installer Updating firmware Once the installer has been run see above the latest version of firmw...

Page 30: ...kHz 30 PPM 43 to 193 kHz jitter rejection at all rates JET technology in TC DICE II 3 dB 10 Hz 100 dB 600 Hz 1 ns peak BW 700 Hz to 100 kHz 0 5 of sample period 50 to 50 of sample period 0 03 0 05 0...

Reviews: