All units come with either Default Master or Default Slave settings. To properly restore the default settings,
please follow the following steps.
For Master:
1. Power off the unit.
2. Set the "DFLT" to on (down) position.
3. Set the unit as Master. "MSTR/SLVE" to up position.
4. Power up the unit and wait for 2 seconds.
5. Set the "DFLT" switch back to off (up) position.
Master IP: 192.168.254.123 Subnet: 255.255.255.0
For Slaves:
1. Power off the unit.
2. Set the "DFLT" to on (down) position.
3. Set the unit as Slave. "MSTR/SLVE" to down position.
3. Power up the unit and wait for 2 seconds.
4. Set the "DFLT" switch back to off (up) position.
Slave IP: 192.168.254.124 Subnet: 255.255.255.0
The "DFLT" LED on the front panel will turn on if the saved settings are the same as the default settings.
In order to configure the TC3420 that is, set to default, the user needs to use a PC with a web browser installed
Furthermore, the PC's IP address must be set within the range of 192.168.254.1 to 192.168.254.254, and with
a Network Mask of 255.255.255.0. If your PC does not have a compatible IP Address and Network Mask
,or you are not sure about the settings, please refer to the "PC Configuration" section for more detail.
To configure the TC3420, simply enter the IP address of the TC3420 in the Web browser's address box. For
Example, if the unit is set as Default Master, enter the following
http://192.168.254.123
(
Attention
: Contact your local area network administrator if you are unsure about the settings. Improper