background image

TC3007 (1X9)

(LED/ELED/LASER)

User's Manual

Rev. 6.0

−4−

Optical Specifications

Transmitter:

LED/ELED; typical Launch Power: -16 dBm* (1310nm, Multimode @62.5/125µm)

LASER; typical Launch Power:

-6 dBm* (1310nm/1550nm, Single Mode @9/125µm)

Receiver:

PIN DIODE; typical Sensitivity:

-33 dBm* (1310nm, Multimode @62.5/125µm)

-36 dBm* (1310nm/1550nm, Single Mode @9/125µm)

Loss Budget: LED/ELEC; 1310nm, MM @62.5/125µm

16 dB

LASER; 1310nm/1550nm, SM @9/125µm

25 dB

Distance:

1310nm, Multimode @62.5/125µm

up to 2km*

1310nm/1550nm, Single Mode @9/125µm (One Fiber)

up to 80km*

Wavelength:

1310nm Multimode (LED/ELED)

1310nm/1550nm Single Mode; LASER (One Fiber)

Connector:

ST or SC

*Launch power, sensitivity and distance are listed for reference only.  These numbers may vary. Contact

factory for higher loss budgets.

Summary of Contents for TC3007

Page 1: ...to any specifica tion TC Communications Inc reserves the right to change or modify the contents of this manual at any time without prior notification TC3007 155 Mbps FIBER OPTIC MODE CONVERTER REPEATE...

Page 2: ...ion Distances typical 4 Launch Power Sensitivity 4 Front Panel LEDs DIP Switches and Connectors 5 Rear Panel Connectors 5 Chapter 2 Installation 6 Unpacking the Unit 6 Equipment Location 6 Power Suppl...

Page 3: ...munication over a single One fiber The optic receiver on the left side detects the incoming optical signal and regenerates it for transmission through the optic transceiver At the receiving end the TC...

Page 4: ...imode 62 5 125 m 36 dBm 1310nm 1550nm Single Mode 9 125 m Loss Budget LED ELEC 1310nm MM 62 5 125 m 16 dB LASER 1310nm 1550nm SM 9 125 m 25 dB Distance 1310nm Multimode 62 5 125 m up to 2km 1310nm 155...

Page 5: ...ived optic power is above sensitivity threshold when lit Single Mode optic receive status SM received optic power is above sensitivity threshold when lit Alarm When lit it indicates a broken fiber con...

Page 6: ...lock connectors on the rear panel labeled PWR A and PWR B Only one pair is required to power the unit Polarity is indicated on each connector block If both pairs are connected the built in power redun...

Page 7: ...tion SM Tx Rx Tx Rx SM Single Mode One Fiber fiber optic cable TC3007 Fiber Optic Mode Converter 1550nm Tx 1310nm Rx 1310nm Tx 1550nm Rx Multimode 1310nm User s Device Rx Tx MM Tx MM Rx Multimode fibe...

Page 8: ...between the fiber connector and the receiver Verify that the equipment is still in sync with the optic signal and that the overdrive condition has been corrected To resolve the overdrive condition per...

Page 9: ...600mA typical Optional 24VDC 48VDC 125VDC or 115 230VAC with an external power cube Temperature Operating 10o C to 50o C Hi Temp Version Optional 20o C to 70o C Storage 40o C to 90o C Humidity 95 non...

Page 10: ...ion may first inspect such goods at the premises of the Buyer or may give written authorization to Buyer to return the goods to TC Communications Inc transportation charges prepaid for examination by...