Button SPEED:

 The default function is to select different available counting speeds.   

Button ↑:

 This button is used to move up the cursor or adjust number magnitude in batch setting mode. 

Button ←: 

The default function is to move the cursor left. When in batch setting mode it chooses the number 

digits. 

Button  →: 

The  default  function  is  to move  the  cursor right.  But  when  in batch  setting mode  it chooses  the 

number digits. And this button also supports to get in the setting menu when in the main interface. 

Button ↓: 

The default function is to move cursor downwards. Adjust number magnitude in batch setting mode. 

ADD/DISP

: The default function is to switch on/off ADD function.   

Button ESC

: The default function is to clear the input or back to upper level.   

Button PRINT

: The default function is to work as a OK or CONFIRMATION. When you press REPORT to check the 

counting detail and your value counter is connected with a printer, then in REPORT mode, press this button to print 
out the detail. 

Button START/RESET

: This button is used to start counting, or back to upper level in MENU.   

 

4.

 

Operation Modes 

4.1

 

CNT mode 

Press button MODE to select CNT mode. In this mode, you can switch on ADD or BATCH or ADD+BATCH.   

 

4.2

 

SDC mode 

Press button MODE to select SDC mode. This mode is to count a single denomination bill.

 

The  system  will  take  the  first  note  as  the  benchmark,  and  will  stop  counting  when  meeting  a  different 
denomination. 

 

4.3

 

MDC mode 

Press button MODE to select MDC model. This mode is a value counting mode for mixed denominations, and press 
REPORT button to check the counting details. 

 

 

5.

 

Maintenance and notice 

     

5.1

 

In order to make sure count display and person safety, you must install good grounding when to use. Safe 
pip rated value is “2A”, not too much.   

 

 

5.2

 

Please  turn  off  the  machine  and  unplug  the  power  cord  when  close  every  day.  To  clean  the  sensors 
(note-feeding sensor, note-receiving sensor and counting sensors) softly with brush, If meet with trouble, 
please ask for repairman to check and repair.

 

 

5.3

 

The time between open and close should be over 5 seconds, to avoid the number of display window being 
disturbed. 

 