Suggested suspension height:
keep the product hanged at a height of 4 ft (1.2 m) at a distance of
1 ft (0.3m) from the wall.
The device can be mounted on the ceiling using a hanging chain.
For installation, drill holes with a 9 mm drill. Depth 80-90 mm.,
Insert into the dowel holes.
Into dowel are screwed hooks, on which an insecticidal lamp is
subsequently suspended using a chain.
SAFETY NOTICES
INSTALLING
HOW TO REPLACE THE LIGHT TUBES
Plug in with dry
hands only
Not allowed for use by
children under 16
Change the attractant only
when the device is turned off
Wash hands with soap after
changin the attractant
Do not leave
unattended
Forbidden for
children to play
STEP 1
STEP 2
Unplug the power cord.
ENSURE screwdriver and
hands are Dry!
Discharge the
internal electrified grid by using a
screwdriver with plastic handle:
Insert the metal tip of
the screwdriver onto the
internal electrified grid.
You may hear and see a
zap.
insert the metal tip of
the screwdriver onto the
internal electrified grid
until there are no zaps.
STEP 3
Flip the device 180 degrees to
the back of the device. Press the
black protective grid down to
the bottom. The protective grid
is spring-loaded, then lower it
down.