background image

eRay Pure Sine Wave Inverter Manual

15

6. Operation

6.1 Double Checking

Check the DC input voltage of this inverter is same to your battery nominal voltage. NEVER try
to connect different DC input to inverter.

Inspect the right polarity of DC on service battery; otherwise the unit cannot be powered ON.

Please check if you connect the Negative terminal of starter battery to the DC – terminal of
inverter.

Inspect AC output is correct; make sure unit is no short circuit.

6.2 Inverter operation

Press shortly the ON/OFF switch on the front panel to turn the inverter power on. After that the “INV”
and “BATTERY” LED indicators are illuminated, and then the inverter is ready to deliver AC power
to the loads.

The ON/OFF switch, dry contact input and optional remote control works independently. It means if
you use one group switch to power on the inverter, you can only use the same group to power off.

6.3 LED indicator status

Figure 6-1 LED indicator of IH2000/IH1500

Figure 6-2 LED indicator of IH1000/IH700

Summary of Contents for eRay IH Series

Page 1: ......

Page 2: ...eRay Pure Sine Wave Inverter Manual WARNING HIGH VOLTAGE INSIDE CAUTION THE DC FUSE MUST HAVE BEENTURNED OFF BEFORE SERVICING MADE IN CHINA...

Page 3: ...About TBB TBB Power is a dedicated designer and manufacturer of sophisticated and environmentally rugged power electronic equipment We are offering a wide range of power conversion product from batte...

Page 4: ...nel 5 3 3 Available sockets type 7 4 Configuration 8 4 1 Set the AC output voltage and frequency 8 4 2 Power saving setting 8 5 Installation 10 5 1 Material list 10 5 2 Location 10 5 3 Wiring Fusereco...

Page 5: ...verheating 2 To avoid fire and electric shock make sure all cables selected with right gauge and being connected well Smaller diameter and broken cable are not allowed to use 3 Please do not put any i...

Page 6: ...igh frequency design featuring compact and light weight 200 surge capability for 1s High efficiency up to 90 Low static consumption power Power save mode through dip switch Thermal control fan With bu...

Page 7: ...eRay Pure Sine Wave Inverter Manual 3 3 Structure 3 1 Product drawing Figure 3 1 1500 2000W Figure 3 2 700 1000W...

Page 8: ...eRay Pure Sine Wave Inverter Manual 4 Figure 3 3 400W Figure 3 4 Optional remote control RIH...

Page 9: ...eRay Pure Sine Wave Inverter Manual 5 3 2 Control panel Rear panel Figure 3 5 1500 2000W Figure 3 6 700 1000W Figure 3 7 400W...

Page 10: ...eRay Pure Sine Wave Inverter Manual 6 Front panel Figure 3 8 1500 2000W Figure 3 9 700 1000W Figure 3 10 400W...

Page 11: ...tor C Remote Dry contact input J ON OFF D Remote Reserved for remote control K AC Output 1 AC output socket E RS485 RS485 port L AC Output 2 AC output socket F USB charger P GND G S2 Dip switch for po...

Page 12: ...S2 The default factory setting of power saving is OFF Figure 4 1 Dip switch 4 1 Set the AC output voltage and frequency Please refer the below table for the dip switch setting Table 4 1 Dip switch set...

Page 13: ...power saving the inverter indicator is flashing During the period when the inverter is in power saving status there is a discontinuous output every 6secs to detect the load status Please adjust the t...

Page 14: ...Cooling Forced air 5 3 Wiring Fuse recommendation Please find the following minimum wire size In case of DC cable longer than 3m please increase the cross section of cable to reduce the loss We recom...

Page 15: ...5 4 2 Connecting the cable Please make sure the inverter is turned off before connection Otherwise high voltage could be present Please double check battery voltage match the model you are going to in...

Page 16: ...y Ensure all the battery cables are tight torque to 12Nm Loose connections may cause overheat and fire Choose the right cable size refer to 5 3 for details and follow polarity guide marked on the pane...

Page 17: ...eRay Pure Sine Wave Inverter Manual 13 Figure 5 2 Connecting diagram of the battery cables Figure 5 3 Connecting diagram of the DC input terminals...

Page 18: ...of them to control the inverter on off either main switch or dry contact 3 Please find the following two recommended wiring for dry contact input Item Description Remote pin 1 Remote pin 2 BAT Notice...

Page 19: ...er Inspect AC output is correct make sure unit is no short circuit 6 2 Inverter operation Press shortly the ON OFF switch on the front panel to turn the inverter power on After that the INV and BATTER...

Page 20: ...audible alarm LED name LED color LED status Indication Beep INV INV OK N A Extinguish Inverter is off Green ON Normal Green Flashing Power saving mode BATTERY Battery Level Red ON 11 0V 22 0V Intermi...

Page 21: ...er The inverter will re start automatically when the input voltage is qualified again Temperature protection check if the fan is working and that the inverter has sufficient ventilation possibilities...

Page 22: ...ace the fuses only equivalent values Input voltage below the minimal value Battery voltage too low or battery defective Input voltage higher than the maximum value Check if the system voltage matches...

Page 23: ...ency 50 0 5Hz Output waveform Pure sine wave Total harmonic distortion 3 Nominal load Short circuit protection 5s auto restart Efficiency Max 90 Output voltage 5 0 25VDC Maximum output current 2A Inpu...

Page 24: ...eRay Pure Sine Wave Inverter Manual 20...