Model No. 

12Vdc 

CPI1000L-LV 

CPI1200L-LV 

CPI1500L-LV

 

  CPI1800L-LV

 

  CPI2000L-LV 

24Vdc 

CPI1000M-LV 

CPI1200M-LV 

CPI1500M-LV 

CPI1800M-LV

   

 

CPI2000M-LV

 

 

48Vdc 

 

 

 

 

 

CPI2000S-LV 

Electrical 
Norminal Voltage 

12Vdc, 24Vdc, 48Vdc 

Cont output power at (40

1000W 

1200W 

1500W 

1800W 

2000W 

Cosφ

 

0.9-1 

Overload   
Capability                                         

>150% 

20s 

>125%   

60s 

>110%   

15mins 

Surge 

300% 

Output voltage 

100/110/120/127VAC ± 2% 

Output frequency 

50/60Hz ± 0.1% 

Efficiency 

12Vdc 

89% 

24Vdc 

92% 

48Vdc 

94% 

Crest factor 

.3:1 

THD   

<3%   

Zero load power   

12.5W 

13W 

14W 

14.5W 

15W 

Zero load power (power save 
mode) 

3W 

3.5W 

3.5W 

3.6W 

3.75W 

Output circuit breaker 

10A 

10A 

10A 

15A 

15A 

Overload and overheat 
protection 

auto disconnect with 3 times restart attempt 

shortcut protection 

auto disconnect     

Other Data 
Dry contact   

Battery low   

Battery connector 

M8 x 2 

Enclosure 

Steel with powder paint 

Dimension (mm)   

460x228x135 

487x228x180 

Net Weight (kgs) 

15 

16 

19 

21 

22 

Cooling   

Forced fan 

Protection 

IP21 

Standard 
Safety   

EN60950-1 

Emmission 

EN55022 

Immunity 

EN55022 

 

 

Summary of Contents for Solar Max CPI Series

Page 1: ...CPI User Manual V1 2 TBB Power Co Ltd Solar Max CPI series Off grid Inverter USER MANUAL Version 1 2 Date Nov 2013 ...

Page 2: ...n be your reliable power solution provider D Di is sc cl la ai im me er r Unless specially agreed in writing TBB Power Co Ltd Take no warranty as to the accuracy sufficiency of suitability of any technical or other information provided in this manual or other documentation Assumes no responsibility or liability for loss or damage whether direct indirect consequential or incidental which might aris...

Page 3: ...1 Please check the input voltage or voltage of battery is same to the nominal input voltage of this inverter 2 Please connect positive terminal of battery to input of the inverter 3 Please connect negative terminal of battery to input of the inverter 4 Please use the shortest cable to connect and ensure the secure connection 5 While connecting please secure the connection and avoid short cut betwe...

Page 4: ...g battery operation 2 0 Description 3 0 Structure 4 0 Setting 4 1 Low Voltage disconnect LVD 4 2 Output Voltage and Frequency 5 0 Control and Communication 5 1 Dry contact 5 2 RCC 6 0 Installation 6 1 Material List 6 2 Location 6 3 Wiring recommendation 6 4 General Advice 6 5 Installation and Connection 7 0 Operation 8 0 Trouble Shooting 9 0 Specification ...

Page 5: ...d be overheating 1 2 2 To avoid fire and electric shock make sure all cables selected with right gauge and being connected well Smaller diameter and broken cable are not allowed to use 1 2 3 Please do not put any inflammable goods near to inverter 1 2 4 Never place unit directly above batteries gases from a battery will corrode and damage inverter charger 1 2 5 Do not place battery over inverter 1...

Page 6: ... which could deliver high quality power with unexpected overload capability Pure Sine Wave Outstanding Peak Power High efficiency up to max 94 Extremely low status consumption power Power save mode available Low voltage disconnect level settable High temperature design Built in auxiliary contact for battery low alarm Comprehensive Protection Remote control available ...

Page 7: ... F Fr ro on nt t P Pa an ne el l A DC cable through hole B Main switch C LED D Gland for remote control cable E Gland for AC output F DC cable through hole S Si id de e P Pa an ne el l On Right side panel there is a circuit breaker as a overload protection for inverter output ...

Page 8: ...CPI User Manual V1 2 TBB Power Co Ltd 7 C Ce en nt tr ra al l P Pa an ne el l A Dry contact battery low B Dip Switch C RCC panel connector D E AC output terminal F DC G DC ...

Page 9: ... Please find following data The following DOD is estimation ONLY The exact measure of the battery SOC is almost impossible with only electrical parameter It may vary according to discharge current battery healthy etc SW1 1 12 2V VD DC C m mo od de el l 2 24 4V VD DC C m mo od de el l 4 48 8V VD DC C m mo od de el l e es st t D DO OD D r re ec co om mm me en nd da at ti io on n off 11 7VDC 23 4VDC ...

Page 10: ...l D Di ip p S Sw wi it tc ch h 2 2 D Di ip p S Sw wi it tc ch h 3 3 O Ou ut tp pu ut t v vo ol lt ta ag ge e o of f H HV V M MO OD DE EL L O Ou ut tp pu ut t v vo ol lt ta ag ge e o of f L LV V M MO OD DE EL L OFF OFF 230VAC 110VAC ON OFF 208VAC 100VAC OFF ON 240VAC 127VAC ON ON 220VAC 120VAC Through the Dip Switch 4 you can configure the output frequency S SW W4 4 H HV V m mo od de e L LV V m mo ...

Page 11: ...old level which is 0 5VDC above the LVD level The maximum contact load is 230Vac 110Vac 2A 12Vdc 24Vdc 48Vdc 2A 5 5 2 2 R RC CC C R Re em mo ot te e C Co on nt tr ro ol l o op pt ti io on na al l Optional RCC remote control could be purchased and connected to the CPI on central panel to have following functions Load percentage Battery SOC battery LED from bottom to top representing 25 50 75 100 Wo...

Page 12: ...entilation Working temperature 10 50 Storage temperature 40 70 Relative Humidity 0 95 non condensing Cooling Forced air 6 6 3 3 W Wi ir ri in ng g r re ec co om mm me en nd da at ti io on n Please find the following minimum wire size In case of DC cable longer than 1m please increase the cross section of cable to reduce the loss System capacity AC wiring DC wiring 110VAC 220VAC 48VDC 24VDC 12VDC 6...

Page 13: ... conductor between battery and CPI which will offer protection to the battery cable On the AC output side we recommend connecting the output from the inverter to a suitable Residual Current Circuit Breaker and Circuit Breaker 6 6 5 5 I In ns st ta al ll la at ti io on n a an nd d C Co on nn ne ec ct ti io on n For the user operation safety cut off the power before installation 6 6 5 5 1 1 F Fi ix ...

Page 14: ...CPI User Manual V1 2 TBB Power Co Ltd 13 Frame B for unit up to 3000W Power Save ON OFF Inverter Fault INVERTER OUTPUT PROTECT Frame C for unit up to 6000W ...

Page 15: ...arity of DC input Reverse polarity could cause permanent damage on equipment and it is out of warranty Choose the right cable size refer to 6 3 and follow polarity guide marked on the panel Pull through the DC cables through the holes at front panel clamping the cable terminal on cable Secure the battery cable on DC and DC terminals respectively making sure it is tightly screwed Connecting the AC ...

Page 16: ...m mo ot te e c co on nt tr ro ol ll le er r The RCC was dash mounting design and can be hanged on wall too For dash mounting please cut the hole according to following size and screw the remote controller securely through four screws at corners and connected the cables Using the two cables supplied connecting the RCC to the port on the central panel Please refer to left picture RCC1 is a 6pin port...

Page 17: ...inverter output The inverter LED will illuminate You could switch on the load which will be powered by inverter The Load LED will reflect the load level connected The SOC led will reflect the battery condition which are 25 50 75 100 respectively from bottom For detail system info you can read out from top panel and remote panel T To op p p pa an ne el l R Re em mo ot te e 7 7 3 3 P Po ow we er r S...

Page 18: ...y Battery overvoltage beep continuously Battery low voltage Inverter overload beep continuously overtemp beep continuously Shortcut beep continuously 8 2 LED indicator on RCC remote panel Status Function LED on remote panel Inverter Fault Inverter Inverter ON Power Save mode flash Alarm Mode Battery low voltage Battery overvoltage Inverter overload Inverter overtemp Protection mode Fan block Batte...

Page 19: ...Surge 300 Output voltage 208 220 230 240VAC 2 Output frequency 50 60Hz 0 1 Efficiency 12Vdc 89 24Vdc 92 48Vdc 94 Crest factor 3 1 THD 3 Zero load power 12 5W 13W 14W 14 5W 15W 18W 26W 32W 36W Zero load power power save mode 3W 3 5W 3 5W 3 6W 3 75W 4 5W 6W 8W 9W Output circuit breaker 10A 10A 10A 15A 15A 30A 30A 30A 30A Overload and overheat protection auto disconnect with 3 times restart attempt s...

Page 20: ...0 Output voltage 100 110 120 127VAC 2 Output frequency 50 60Hz 0 1 Efficiency 12Vdc 89 24Vdc 92 48Vdc 94 Crest factor 3 1 THD 3 Zero load power 12 5W 13W 14W 14 5W 15W Zero load power power save mode 3W 3 5W 3 5W 3 6W 3 75W Output circuit breaker 10A 10A 10A 15A 15A Overload and overheat protection auto disconnect with 3 times restart attempt shortcut protection auto disconnect Other Data Dry cont...

Reviews: