background image

                                                                      Energier Mobile User Manual 

 

14 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Energier Mobile CC2.0L

Page 1: ......

Page 2: ...Energier MobileUser Manual...

Page 3: ...Energier MobileUser Manual WARNING HIGH VOLTAGE INSIDE CAUTION THE DC FUSE MUST HAVE BEENTURNED OFF BEFORE SERVICING MADE IN CHINA...

Page 4: ...ble for Energier Mobile Inverter Charger Combination This chapter contains important safety and operation instructions Read and keep this User Guide well for later reference The Energier Mobile Invert...

Page 5: ...Remote control and monitor MCK 4 2 2 4 Connection compartment 5 2 2 5 Dimension 6 2 3 Function 6 2 3 1 Powerful and Reliable Inverter 6 2 3 2 Professional Battery Charger for lead acid battery 7 2 3 3...

Page 6: ...ation otherwise the Energier Mobile Inverter Charger Combination would be overheating To avoid fire and electric shock make sure all cables selected with right gauge and being connected well Smaller d...

Page 7: ...compressor power tool etc With the function of power assist power control it can be used to work with a limited AC source such as generator or limited grid Energier Mobile can automatically adjust its...

Page 8: ...cture 2 2 1 Front Figure 2 1 Inverter Charger Combination structure in front view 2 2 2 Control panel Mode LED Indication ON OFF Power LED Indication Mute Unlock the fault and alarm Figure 2 2 Inverte...

Page 9: ...ill flash when CC have warning Fault It will flash when CC have error 2 2 3 Remote control and monitor MCK Apart from above control panel the user is also allowed to monitor control and configure CC b...

Page 10: ...A dry contact input for remote on off often IGN was connected Com MON RS485 port for external monitor such as MCK SNMP etc Com Sync Communication with TBB s M or P series lithium battery which is able...

Page 11: ...utility grid Pure sine wave can guarantee the correct function of sensitive equipment computer laser printer TV etc Also your home appliances will work smoother cooler and more efficient such as fridg...

Page 12: ...e charging formula must be adjusted automatically and in real time according to the actual battery temperature to ensure that battery is fully charged but not overcharged or undercharged All charging...

Page 13: ...start automatically At this time the user needs to manually restart Over temperature protection When the internal temperature is too high Energier Mobile will enter into the over temperature protectio...

Page 14: ...ore flammable explosive or corrosive gases or liquids in the working environment Don t install in a working environment with metal conductive dust Please install the equipment in a location of dry cle...

Page 15: ...step Step 1 Turn on the circuit breaker between the battery and the inverter Step 2 Press the On Off button to turn on the inverter entering into self diagnostic Step 3 Set the parameters following th...

Page 16: ...Battery Battery Type AGM Battery AH 200AH Max Charge Current 100 of the Max charge current Absorption Voltage 14 1 Float Voltage 13 7 Undervoltage Protect Recover 13 0 Undervoltage Warning 11 0 Under...

Page 17: ...2 5 2 2 TBB Link The TBB Link is a powerful tool or CC3 0L series inverter Configuration The TBB Link can be installed on the computer open the TBB Link and turn on the inverter the inverter can be co...

Page 18: ...types AGM GEL OPZV Lead Carbon Li ion Flooded Battery Charge current 100A 150A Temperature compensation Yes General data AC Out Current 32A Transfer time 4ms 15ms when WeakGrid Mode Remote on off Yes...

Page 19: ...Energier Mobile User Manual 14...

Page 20: ...Energier Mobile User Manual 15...

Reviews: