X4 AC Drive User’s Manual
Chapter 7: X4 Parameters
1428D-0607
- 74 -
© 2007 TB Wood’s All Rights Reserved
910 Vin1 Status
911 Cin Status
912 Vin2 Status
Default: Read-Only
Range: 0.00-100.00%
Level 2 (SIO)
Parameter 910 provides the input percentage applied to the Vin1 terminal; parameter 911 provides the input percentage
applied to the Cin terminal; and parameter 912 provides the input percentage applied to the Vin2 terminal.
913 Output Status
Default: Read-Only
Range: n/a
Level 2 (SIO)
This parameter provides a 10-bit binary status display. A “1” in the status word indicates that the output is active.
The following bits are used with this parameter:
914 Vmet Status
915 Imet Status
Default: Read-Only
Range: 0.00-100.00%
Level 2 (SIO)
Parameter 914 provides the output percentage applied to the Vmet terminal; parameter 915 provides the output
percentage applied to the Imet terminal.
916 Infrared Baud
Default: 9600
Range: n/a
Level 2 (SIO)
This parameter defines the baud rate of the IRDA port.
The following data values may be assigned to this parameter:
Parameter Value
9600
19200
38400
57600
931 Seq Cntl 1
932 Seq Cntl 2
933 Seq Cntl 3
934 Seq Cntl 4
935 Seq Cntl 5
936 Seq Cntl 6
937 Seq Cntl 7
938 Seq Cntl 8
939 Seq Cntl 9
Default: 00000000000
Range: n/a
Level 2 (SEQ)
These parameters each provide a 10-bit binary status display. See “Using the X4 Program Sequencer” on page 75.
The following bits are used with each of these parameters:
Bit 0-2=Speed Sel
Bit 3=Accl Sel
Bit 4-6=Event Length
Bit 7-8=Dir Sel
Bit 9-10=Output Sel
Table 7-2: Description of X4 Parameters (Page 25 of 26)
Bit
When Set to 1 Signifies
Bit
When Set to 1 Signifies
5
N/A
0
R1 Output
6
N/A
1
R2 Output
7
N/A
2
DO1 Output
8
N/A
3
DO2 Output
9
N/A
4
N/A
9
8
7
6
5
4
3
2
1
0