27 - ENGLISH
8.2 HEATER TROUBLESHOOTING
PROBLEM
PROBABLE CAUSES
REMEDIES
Master switch open.
Close the switch.
Electrical anomaly.
Contact the technician.
The machine does not start
(STOP button off).
Fuses blown.
Contact the technician.
After the extraction there is
still too much product in the
vessel
Insufficient rear feet adjustment.
Adjust the rear feet so that the
product contained in the vessel
comes out.
Product insufficient.
Work with at least 1/2 the
maximum amount of product
allowed.
Open lid.
Make sure that the lid is
assembled and closed properly.
The machine works regularly
but the heating times are
long.
Faulty resistance or fluid pump.
Contact the technician.
During functioning the
machine becomes noisy and
the beater stops.
The belt slips.
Contact the technician to check
the belts tension and possibly
replace it.
The machine becomes noisy
during operation.
Transmission shaft without
lubrication.
Remove the mixer and pull the
transmission shaft upwards.
Verify and lubricate with food
grease.
The machine does not heat
within normal time and a loss
of blue fluid is detected
under the machine.
Loss of glycol from the system.
Contact the technician.
Summary of Contents for Frigomat CH02 Series
Page 1: ...MANUALE D USO E MANUTENZIONE OPERATING INSTRUCTION AND MAINTENANCE Serie Series CH02 05...
Page 30: ...APPENDICI 2 9 2 Schema circuito frigorifero Refrigerant circuit diagram...
Page 33: ...5 APPENDICI CH02 s05 Tav 1...
Page 35: ...7 APPENDICI CH02 s05 Tav 2...
Page 37: ...9 APPENDICI CH02 s05 Tav 3...
Page 39: ...11 APPENDICI CH02 s05 Tav 4...
Page 41: ...NOTE NOTES NOTES BEMERKUNG NOTA...
Page 42: ......