Model C723
Introduction
Wash Symbol
The WASH symbol
will illuminate when it is
touched. This indicates beater motor operation. The
STANDBY or AUTO modes must be cancelled first
to activate the WASH mode.
Auto Symbol
The AUTO symbol
will illuminate when it is
touched. This indicates that the refrigeration system
has been activated. In the AUTO mode, the WASH
or STANDBY functions are automatically cancelled.
Note:
An indicating light and an audible tone will
sound whenever a mode of operation has been
selected. To cancel any function, touch the key
again. The light and the mode of operation will shut
off.
Reset Mechanism
The reset buttons are located in the left side panel of
the machine. They protect the beater motors from
an overload condition. Should an overload occur, the
reset mechanism will trip. To properly reset the
freezer, place the power switch in the OFF position.
Press the reset button firmly. Turn the power switch
to the ON position. Touch the WASH symbol
and
observe the freezer's performance.
WARNING: Do not use metal objects to
press the reset button.
Failure to comply may
result in severe personal injury or death.
If the beater motor is turning properly, touch the
WASH symbol
to cancel the cycle. Touch the
AUTO symbol
to resume normal operation.
Feed Tube
The feed tube serves two purposes. One end of the
feed tube has a hole in the side of the tube and the
other end does not. The air orifice is used to meter a
certain amount of air into the freezing cylinder. It
maintains overrun and allows enough mix to enter
the freezing cylinder after a draw. (See Figure 5.)
Figure 5
1.
Normal Operation
During normal operation, the end of the feed
tube
with the hole is placed into the mix inlet
hole. Every time the draw handle is raised, new
mix and air from the hopper flow into the
freezing cylinder. This keeps the freezing
cylinder properly loaded and maintains overrun.
2.
Long “No Sale” Periods
During long “No Sale” periods, the unit can be
placed in the Standby mode. This maintains
product temperatures below 40°F (4.4°C) in
both the hopper and the freezing cylinder, and
helps prevent overbeating and product
breakdown.
To activate Standby, select the STANDBY key
or enter the access code for the Manager Menu
and select the Standby Mode option (see
pages 17 and 20). The STANDBY symbol
will illuminate, indicating the Standby feature
has been activated.
Using clean and sanitized hands, remove the
air orifice. Lubricate the o-rings located on the
end of the feed tube without the hole. Place
that end of the tube into the mix inlet hole.
Note:
To resume normal operation, press the
AUTO symbol
. When the unit cycles off, the
product in the freezing cylinder will be at
serving viscosity. Using clean and sanitized
hands, turn the feed tube over and place the
end of the tube with the hole into the mix inlet
hole. Install the air orifice.
Summary of Contents for C723
Page 2: ......
Page 39: ...35 Model C723 Controls Systems and Operations 140519 C723 Control Overview Figure 72 ...
Page 41: ...37 Model C723 Controls Systems and Operations 130409 Refrigeration Schematic Figure 73 ...
Page 52: ...48 Troubleshooting Model C723 Notes ...
Page 55: ...51 Model C723 Parts Notes ...
Page 56: ...52 Parts Model C723 150603 Model C723 Exploded View Figure 74 ...
Page 59: ...55 Model C723 Parts 140519 Model C723 Operator Parts Figure 75 ...