6-6
OPERATING PROCEDURES
Model 490
Operating Procedures
6
Priming
1.
With a pail beneath the door spout, raise the draw
arm. Pour 2 gal. (7.6 L) of
fresh
mix into the hopper
and allow it to flow down into the freezing cylinder.
This will force out any remaining sanitizing solution.
When full-strength mix is flowing from the door spout,
lower the draw arm.
2.
Open the prime plug by turning it counterclockwise
until the air in the freezing cylinder is allowed to
escape.
3.
When product starts flowing from the bleed port,
close the prime plug by turning it clockwise until it is
snug against the freezer door.
Important! Failure to remove all sanitizing solution
may result in damage to the freezing cylinder.
4.
Install the air tube in the mix inlet hole.
Figure 6-22
5.
Fill the hopper with mix.
6.
Place the control switch in the
Auto
position. Rotate
the draw valve away from the draw arm as shown in
Figure 6-23. Lift the draw arm to start the
compressor.
Figure 6-23
Rotate the draw valve back to its normal position on
the draw arm. When the unit cycles off, the product
will be at serving temperature.
7. Place the mix hopper cover in position.
Note: When drawing product, gently raise the draw
arm to the fully opened position.
Closing Procedures
To disassemble the Model 490, the following items will be
needed:
•
Two cleaning pails
•
NSF-approved sanitized stainless steel rerun
can with lid
•
Cleaning brushes (provided with freezer)
•
Cleaner
•
Single-service towels
Draining Product from the Freezing
Cylinder
1. Place the control switch in the OFF
position.
2. Remove the hopper cover and air tube. Take these
items to the sink for cleaning.
3.
If local health codes permit the use of rerun,
place
a sanitized, NSF approved stainless steel rerun
container beneath the door spout. Place the control
switch in the Wash position and raise the draw arm.
When all the product stops flowing from the door
spout, lower the draw arm and place the control
switch in the OFF position. Place the sanitized lid on
the rerun container and place it in the walk-in cooler.
See page 7-1 for instructions regarding the proper
use of rerun.
Note: If local health codes do not permit the use
of rerun,
the product must be discarded.
Follow the
instructions in the previous step, except drain the
product into a pail and properly discard the mix.
12253
101109
!
ALWAYS FOLLOW LOCAL HEALTH CODES.
Summary of Contents for 490
Page 16: ...4 4 OPERATOR PARTS IDENTIFICATION Model 490 Operator Parts Identification 4 Notes...
Page 18: ...5 2 USER INTERFACE Model 490 User Interface 5 Notes...
Page 32: ...9 2 PARTS REPLACEMENT SCHEDULE Model 490 Parts Replacement Schedule 9 Notes...
Page 38: ...11 4 LIMITED WARRANTY ON PARTS Model 490 Limited Warranty on Parts 11 Notes...