18
Troubleshooting
Model 428
Troubleshooting Torque Components
A. A missing or worn guide bearing will cause
uneven movement of the rotor system and will
result in product inconsistencies (too stiff/too
thin). If product becomes too stiff, the door,
torque arm, torque rotor and torque lever may be
damaged.
B. Any distortion or incorrect assembly of the torque
rotor will damage the torque components.
C. If incorrectly sized, damaged or improperly
lubricated o-rings are used, the rotor, door,
torque arm, torque rotor and torque lever may be
damaged.
D. If the torque arm is missing, the product will
freeze and the pulley belt will begin slipping. The
beater reset will then deactivate freezer
operation. In addition, torque components may
be damaged.