m
•
Never connect the generator to the power
supply (socket-outlet).
•
Keep the cable length to the consumer as
short as possible.
5.2 Environmental protection
•
Dispose of soiled maintenance material
and operating materials at the appropriate
collection point.
•
Recycle packaging material, metal and
plastics.
5.3 Connecting to earth
The housing is allowed to be connected to earth
in order to discharge static electricity. To do this,
connect one end of a cable to the earth
connection on the generator (Fig. 4) and the
other end to an external earth (for example an
earthing rod).
6. Operation
Important!
You must fill up with engine oil
(approx. 0.6 l) and fuel before you can start the
engine.
•
Check the fuel level and top it up if
necessary
•
Make sure that the generator has sufficient
ventilation
•
Make sure that the ignition cable is secured
to the spark plug
•
Inspect the immediate vicinity of the
generator
•
Disconnect any electrical equipment which
may already be connected to the generator
6.1 Starting the engine
•
Open the petrol cock (13) by turning it down
•
Move the ON/OFF switch (10) to position
“ON”.
•
Move the choke lever (11) to position IØI.
•
Start the engine with the reversing starter
(12) by pulling the handle forcefully. If the
engine does not start, pull the handle again.
•
Push the choke lever (11) back again after
the engine has started.
Important!
When starting with the reserve
starter, the motor may recoil suddenly as it starts
up, resulting in hand injuries. Wear protective
gloves when starting the equipment.
6.2 Connecting consumers to the generator
•
Connect the equipment you want to use to
the 240 V~sockets (3)
Important:
These sockets may be loaded
continuously (S1) with 2000W and temporarily
(S2) for a maximum of 2 minutes with 2200W.
•
The generator is suitable for 240 V~ AC
appliances.
•
Do not connect the generator to the
domestic power network as this may result
in damage to the generator itself or to other
electrical appliances in your home.
Note: Some electrical appliances (power jigsaws,
drills, etc.) may have a higher level of power
consumption when used in difficult conditions.
6.3 Switching off the engine
•
Before you switch off the generator, allow
it to run briefly with no consumers so that it
can “cool down”
•
Move the ON/OFF switch (10) to position
“OFF” with the key.
•
Close the petrol cock
Important! The generator is fitted with an
overload cut-out.
This shuts down the sockets (3). You can restart
the sockets (3) by pressing the overload cut-out
(5).
Important! If this happens, reduce the electric
power you are taking from the generator or
remove any defective connected appliances.
Important! Defective overload cut-outs must be
replaced only by overload cut-outs of identical
design and with the same performance data. If
repairs are necessary, please contact your
customer service center.
7. Cleaning, maintenance
and ordering of spare
parts
Switch off the motor and pull the spark plug boot
from the spark plug before doing any cleaning and
maintenance work on the equipment.
Important: Switch off the machine immediately
and contact your service station:
•
In the event of unusual vibrations or noise
•
If the engine appears to be overloaded or
•
misfires
7.1 Cleaning
•
Keep all safety devices, air vents and the
motor housing free of dirt and dust as far as
possible.
11