20
5
PRE-
FLASHING
On
the pre-flashing function is enabled.
Off
the pre-flashing function is disabled.
6
FOTOTEST
On
the “photocell test” function is enabled.
Off
the “photocell test” function is disabled.
Note: to be used when the photocells are not used.
7
MASTER/
SLAVE
On
enables the MASTER mode in the master/slave configuration (see T-COMM
instructions).
Off
enables the SLAVE mode in the master/slave configuration (see T-COMM
instructions), or standard operation (single motor).
8
WITH LIMIT
SWITCHES:
SELECTION
TOWARDS OPENING
On
operation for gate with opening to the right (gearmotor side);
Off
operation for gate with opening to the left (gearmotor side);
WITHOUT LIMIT
SWITCHES:
BACK JUMP
On
once the mechanical stop of the closing maneuver is reached, the automa
-
tion makes a slight movement in the opposite direction to avoid jamming
between the rack and the pinion.
Off
function deactivated
To change the position of Dip 8, the power must be disconnected. Once modified, rerun
the SetUp of the stroke
9-10-11
NOT USED
12
SENSITIVE
EDGE
On
RESISTIVE SENSITIVE EDGE 8,2 KΩ (terminal No. 10).
Off
NC CONTACT
SENSITIVE EDGE ( terminal No. 10).
Note: if not used, keep the DIP in the OFF position.
6. MEMORIZATION PROCEDURE OF THE STROKE
WARNING: After powering the control panel, wait 2 seconds before you start performing the
adjustment operations and check:
- The Input connections: all green DL5, DL6, DL7, DL8 must be on steady.
- The mechanical stops of the automation must be installed and adjusted both in opening and
in closing [see motor instructions].
IMPORTANT: Carry out the first stroke memorization with the RAL trimmer positioned
fully turned counterclockwise (minimum deceleration speed).
- If the gate fails to move forward during the stroke memorization procedure, it is possible to increase
the speed using the CH1 (= - minus) and CH2 (= + increase) keys. To adjust the speed, briefly press the
buttons.
N.B .: The speed changes made during this phase using the CH1 and CH2 keys are not permanent (valid
only to memorize the stroke ).
Remember to decrease the speed through CH1 during the closing/opening stop phase as there is a
risk that the gate will slam the mechanical stop.
PROCEDURE WITHOUT LIMIT SWITCHES INSTALLED:
1.
Start the procedure with the gate at approx. 0.5 m from the mechanical opening stop.
If the automation closes instead of opening, stop the run of the gate (by cutting
the photocells or closing the STOP contact), invert the polarity of the motor, take
the gate at approx 0,5 m from the mechanical stop) and restart the procedure
from the beginning.
Make sure you don’t stand near the automation during saving.
2.
Press without releasing the PROG button (6 sec. ca.) till the DL2 LED starts flashing (orange):
3.
The automation starts to open slowly in search of the opening stop;
4.
Once the opening stop is reached, the automation slowly starts closing in search of the closing stop;
ENGLISH