background image

1

Italiano

K101M

Quadro di comando per barriera automatica RBLO-E

IT - Istruzioni originali

TAU srl 

- Via Enrico Fermi, 43 - 36066 Sandrigo (VI) - Italy

Tel +39 0444 750190 - Fax +39 0444 750376

www.tauitalia.com

D_MNL0K101M

 21-10-2020 - Rev.06

K101M

FR

SENS

TCA

F2

F1

7

6

5

8

9

10

11

12

13

14

1

2

3

Neutral

230 V AC

Power supply

Phase

M-OP

CLS

OLS

COM

FS1

FS2

M-COM

M-CL

4

RADIO

OP/CL

RESET

DL3

DL4

DL5

DL6

DL2

DL1

1

2

3

4

5

6

1

2

3

4

5

6

Flashing light 230 

V AC

max. 50W

Flashing light VLED DC

Open/Close

+

-

Stop

Antenna

Dip-switches

ON

M2

J4

SM

M3

DL3

DL4

DL5

DL6

DL2

DL1

PHOT

O

CLOSE LIMIT

 SWITCH

OPEN LIMIT

 SWITCH

ST

OP

OPEN/CLOSE

RADIO CONTROLS

TCA

+
-

SENS

+
-

FR

+
-

Photocells

Common

Photocell (N.C.)

RX

1

2

3

4

5

TX

1

2

V AC

Photocell - 24 V 

AC

Summary of Contents for K101M

Page 1: ... 8 9 10 11 12 13 14 1 2 3 Neutral 230 V AC Power supply Phase M OP CLS OLS COM FS1 FS2 M COM M CL 4 RADIO OP CL RESET DL3 DL4 DL5 DL6 DL2 DL1 1 2 3 4 5 6 1 2 3 4 5 6 Flashing light 230 V AC max 50W Flashing light VLED DC Open Close Stop Antenna Dip switches ON M2 J4 SM M3 DL3 DL4 DL5 DL6 DL2 DL1 PHOTO CLOSE LIMIT SWITCH OPEN LIMIT SWITCH STOP OPEN CLOSE RADIO CONTROLS TCA SENS FR Photocells Common...

Page 2: ...ATO DA LEDs PROTEZIONE INGRESSO LINEA CON FUSIBILE CIRCUITO DI LAMPEGGIO INCORPORATO RADIO RICEVITORE 433 92 MHz INTEGRATO TEMPO DI LAVORO FISSO max 40 sec RILEVAMENTO AUTOMATICO DELLA FREQUENZA DI ALIMENTAZIONE 50 o 60 Hz RALLENTAMENTO REGOLABILE COMPATIBILITÁ CON L APP TAUOPEN E TAUAPP ATTENZIONE In caso di lunghi tratti di cavi 20 m per i comandi N A N C es APRE CHIUDE STOP PEDONALE ecc al fine...

Page 3: ... trimmer in senso orario la rileva zione del fermo di battuta fine corsa sarà più sensibile Viceversa ruotando in senso antiorario diminuirà la sensibilità Con il trimmer nella posizione minima il motore rimarrà alimentato per il tempo totale impostato dal dip switch 6 nonostante l accostamento al finecorsa meccanico avvenga precedentemente È pertanto necessario regolarlo correttamente per evitare...

Page 4: ...CH2 in questo caso il led DL8 si accende con colore rosso 8_ se si desidera uscire dalla modalità di apprendimento senza memorizzare un codice premere brevemente il tasto CH1 o il tasto CH2 Nel caso di raggiungimento del nr massimo di radiocomandi nr 30 il led DL8 lampeggia velocemente per circa 3 secondi senza però eseguire la memorizzazione PROGRAMMAZIONE REMOTA TRAMITE T 4RP e K SLIM RP S 2RP S...

Page 5: ...emuti i tasti CH1 e PROG fino a che i led DL7 e DL8 iniziano a lampeggiare velocemente entrambi in giallo A questo punto rilasciare i tasti e premerli nuovamente fino a che i led si spengono a conferma che l operazione è terminata se non vengono premuti e si resta in attesa la scheda ritorna in funzionamento normale dopo circa 12 secondi RESET DI FABBRICA tenere premuti i tasti CH2 e PROG fino a c...

Page 6: ... 6 5 8 9 10 11 12 13 14 1 2 3 Neutral 230 V AC Power supply Phase M OP CLS OLS COM FS1 FS2 M COM M CL 4 RADIO OP CL RESET DL3 DL4 DL5 DL6 DL2 DL1 1 2 3 4 5 6 1 2 3 4 5 6 Flashing light 230 V AC max 50W Flashing light VLED DC Open Close Stop Antenna Dip switches ON M2 J4 SM M3 DL3 DL4 DL5 DL6 DL2 DL1 PHOTO CLOSE LIMIT SWITCH OPEN LIMIT SWITCH STOP OPEN CLOSE RADIO CONTROLS TCA SENS FR Photocells Co...

Page 7: ...N CONTRACT TORT OR ANY OTHER LEGAL THEORY DURING THE COURSE OF THE WARRANTY OR AT ANY TIME THEREAFTER 2 CONTROL PANEL FOR 230 V ac BARRIER MICROPROCESSOR CONTROLLED LOGIC STATUS LEDS LINE FUSE BUILT IN FLASHING LIGHT CIRCUIT BUILT IN 433 92 MHz RADIO RECEIVER MAX OPERATING TIME 40 AUTOMATIC 50 60 HZ FREQUENCY DETECTION ADJUSTABLE SOFT STOP COMPATIBILITY WITH OUR APPS TAUOPEN AND TAUAPP ATTENTION I...

Page 8: ...mechanical limit switches By turning the trimmer clockwise the detec tion of the limit stop will be more sensitive On the contrary by turning counterclockwise the sensibility will decrease With the trimmer in the minimum position the motor will remain powered for the total time set by the dip switch n 6 even though the mechanical limit switch has been already reached It is therefore necessary to a...

Page 9: ...y for about 3 seconds but with out performing memorisation REMOTE PROGRAMMING BY MEANS OF T 4RP K SLIM RP S 2RP S 4RP V 4 X With the new version of software V 4 X it is possible to carry out the remote self learning of the new version of transmitters T 4RP K SLIM RP S 2RP S 4RP V 4 X that is without pressing the receiver s programming buttons It will be sufficient to have an already programmed tra...

Page 10: ...ance with European Directive 2006 42 EC App II B Manufacturer TAU S r l Address Via E Fermi 43 36066 Sandrigo Vi ITALY Declares under its sole responsibility that the product Electronic control unit designed for automatic movement of Road barriers for use in a General environment complete with Radioreceiver Model K101M Type K101M Serial number see silver label Commercial name Control panel for aut...

Page 11: ...11 ...

Page 12: ...Via Enrico Fermi 43 36066 Sandrigo VI Italy Tel 39 0444 750190 Fax 39 0444 750376 info tauitalia com www tauitalia com ...

Reviews: