State
Red LED
Red LED
Red LED
Green LED
Green LED
Green LED
Non-Detect
ON
ON
OFF
7. LED information
2
3
4
Cut out the Side Cover wiring point and insert the
Wire Sheath into it.
Attach the Side Cover with
Screws provided.
14. Dimensions
Screw
6. Timing chart of events
Relay Output / Test Input
DETECTION as
response to TEST
POWER OFF NO DETECTION
NO DETECTION
DETECTION
TEST RESPONSE
T
Test Input
NON-TEST
NON-TEST
TEST
B
Dip Switch #3
Dip Switch #1
T : 8 to 18 [mSec]
Test Input
Relay Output Mode
Interromperelacorrente
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
T
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
COM
NC
NO
NC
A
6
7
6
7
6
7
Supplying DC12 to 24V,
make current flow from
7th terminal to 6th.
Sensor
Sensor
Sensor
Sensor
Sensor
Sensor
6
7
6
7
6
7
12. Final Detection Range Check
After the Filter Cover is fitted, confirm that the detection range is as expected
and conforms with local regulations.
13. Technical Data
MODEL
TECHNOLOGY
POWER SUPPLY
CURRENT
CONSUMPTION
RELAY OUTPUT
TEST INPUT
OPERATING
TEMPERATURE
MOUNTING HEIGHT
DETECTION RANGE
WEIGHT
95 [mA] a DC12[V]
55 [mA] a DC24[V]
1.7 [VA] a AC12 [V]
2.3 [VA] a AC24[V]
OPTO RELAY 1A (NON POLE)
DC 50[V] 0.1[A] (RESISTANCE LOAD)
RESPONSE SPEED
DIP SW FUNCTIONS
TEST INPUT : 1 [BIT]
OPTICAL INTERFERENCE : 1 [BIT]
RELAY OUTPUT MODE :1 [BIT]
MASKING DETECTING SPOTS:2[BIT]
DETECTION RANGE:3[BIT]
LESS THAN 100 [mSec]
AC/DC 12
〜
24[V] ±10%
BEAM ANGLE
ADJUSTMENT
5 , 10 , 15 , 20 , 25 [degrees]
COMPLETE STATIONARY DETECTION with PSD DISTANCE MEASUREMENT
2,6 [m] ma
x
0 - 2,55 [m] Ma
x
-20
〜
+60 [
゜
C]
6 [mA] ma
x
. a 24 [V CC]
OFF
7-1 Normal state
Detect
PCB unit
7-2 Error state
Cause
“N”
times
N
1
3 over
Error category
Environmental error
Environmental noise or the
reflection level from the floor is
too low.
Execute the “TEACH” from
Section 8 whilst laying a sheet
of white paper on the floor.
Other Error
Internal component failure
Change the units.
7-3 Teaching state
See Section 8
8. Teaching
Conduct the following steps with the Filter Cover off.
1) Check the wiring connection and supply power.
2) Execute “TEACHING”
“TEACHING” is necessary to make the sensor work properly, that is to learn the distance from
the sensor to the floor.
STEP 1.
Press the “Push SW" switch
for more than 2 seconds.
STEP 2.
LED blinks slowly for 10 sec’s in a non-detection
state. Ensure that there are no people or objects
(ladder etc) in the detection area during this time.
STEP 3.
After STEP2, LED blinks faster and starts " TEACHING". If during
this time, a person or object is in the detection area, try again from
STEP 1.
STEP 4.
After STEP3, the green LED blinks once and then this process is
completed.
9. Detection Area
9.1 FRONT VIEW
9.2 SIDE VIEW
2000
2600
400 200
0
600
1000
1000
2000
2600
400 200
600
800
1000
0
5
25
10. Detection Range Check without Filter Cover
Check the detection range without the Filter Cover attached.
Put a test object in the detection area to check the detection patterns and other Dip Switch
settings. Tests according to local standards should be carried out.
After this check, Turn power off.
Description of Product:
DOORSS Safety Sensor for Swing Doors .
Complete stationary detection with PSD distance measurement.
15. EC DECLARATION OF CONFORMITY
Check that the detection area conforms to EN16005
When the test is completed, go to Section 11 to install the Filter Cover and Side Cover.
If an error occurs, re-check the settings referring to Section 3.
EN16005
Check that the detection area conforms to EN16005
EN16005
1200
Check the adjustments , range and other setting.
3
Date
Unit: [mm]
11. Replacing the Filter Cover and Side Cover
1
CAUTION
!
Be careful not to obstruct
the optical components
with wires.
800
1000
1) First fit the upper side of the Filter Cover into the full
length of the Aluminum Case.
2) Slightly bend the Filter Cover at one end to latch
it onto the bottom lip of the Aluminum Case.
3) Slide your hand along the bottom lip to lock the Filter Cover
onto the Aluminum Case all along the length of the Aluminum
Case.
1) Snap the Joint into the Aluminum Case.
2) Slide the Joint so that it fits snugly into the Filter Cover. Make sure there are no gaps left.
3) Attach remaining Filter Covers as illustrated
1
2
3
5
3
4
5
3
4
5
3
4
5
3
4
5
3
4
5
3
4
5
3
4
5
3
4
5
3
4
5
3
4
5
3
4
5
3
4
Safety Sensor for Swing Doors
DOORSS
Compiler of Technical File (EC Community)
Loris Virgilio Danieli
TAU S.r.l. - Via E. Fermi, 43 - 36066 Sandrigo (VI) - IT
Tel: +39 0444 750190 - Fax: +39 0444 750376
Declaration made by
Loris Virgilio Danieli
Location of Declaration
(Manufacture)
TAU S.r.l..
Via Enrico Fermi, 43
Sandrigo (VI), Italia
05-02-2018
D-MNL 0DOORSS
TAU S.r.l.
Via Enrico Fermi, 43
36066 Sandrigo (VI) - Italy
e-mail: [email protected]
Tel.: +39 0444 750190
Fax: +39 0444 750376
www.tauitalia.com
Solution
Red LED
Green LED
Red LED
Green LED
Red LED
Green LED
Attaching the Joint
Directives Fulfilled:
DIRECTIVE 2006/42/EC
Machinery Directive
DIN 18650-1:2010
Powered pedestrian doors Part 1: Product requirements. Chapter 5.7.4
EN12978:2003 +A1:2009
Industrial, commercial and garage doors and gates - safety devices for power operated doors
and gates - Requirements and test methods.
EN62061:2005
Functional safety of electrical/electronic/programmable electronic safety-related systems.
EN ISO 13849-1:2008 /AC:2009
Safety of machinery - Safety-related parts of control systems.
EN 16005:2012
Power operated pedestrian doorsets - Safety in use - Requirements and test methods. Chapter 4.6.8
EC type examination No. 44 205 13738001
Above EC Type Directives Certified by:
TUV NORD CERT GmbH
Langemarckstr.20 45141 Essen Germany
Harmonized Standards
Used:
EN ISO 13849-1:2008/AC:2009
Other Technical Standards
Used:
DIN 18650-1:2005
EN16005:2012
<
Disclaimer
>
The manufacturer cannot be held responsible for the below.
1. Misinterpretation of the installation instructions, miss connection, negligence, sensor modification and inappro
-
priate installation.
2. Damage caused by inappropriate transportation.
3. Accidents or damages caused by fire, pollution, abnormal voltage, earthquake, thunderstorm, wind, floods and
other acts of providence.
4. Losses of business profits, business interruptions, business information losses and other financial losses caused by
using the sensor or malfunction of the sensor.
5. Amount of compensation beyond selling price in all cases.
Rev. 02 31/08/2023
Unità: [mm]
DOORSS340: CIRCA 350 [g]
DOORSS1023T: CIRCA 760 [g]
48
50
,5
1023
DOORSS1023T
DOORSS340
47,5
49
360