background image

1. General Description / Features

2. Components

3. Mounting and Wiring Information

3.1. Notice

CAUTION

WARNING

!

1

2

3

Do not mount the

sensor higher than

2.6 [m]( 8' 6" ).

Do not mount the

sensor where rain or

snow will fall directly

on the unit.

Ensure the minimum

of reflected sunlight

from the floor.

Ensure no condensation

gets onto the sensor.

4

The Aluminum

Case(s) should be

located close to the

Leading edge of the

door to maximise

safety detection.

5

3.2 Mounting Hole

3.3 Mounting the Aluminum Case

1)

2)

1

2

3

4

3.5 Wiring to the door controller

Install the Jamb Hole Cover and Wire Sheath when wiring to the door controller.

Connect the wires to the

door controller using the

Terminal Block

Drill following holes.

Clamp the Wire Sheath between the Jamb Hole Cover A/B

Unit : [mm]

30

10

15

Screw Holes

Wiring Hole

CAUTION

!

Length

[mm]

Filter

Cover

Installation

Instruction

Wire Sheath

600 [mm]

(1)

(3)

(2)

Mounting

Screws

4×16 [mm]

(5)

Mounting

Screws 

3x10 [mm]

Jamb Hole 

Cover A/B

Accessories

Before mounting this sensor please note the following remarks.

!

2,6 [m]

Joint

3 -

φ

2,6

φ

10

English

Note

WARNING

!

CAUTION

!

EN16005

Model name

3.4 Replacing the PCB unit(s)

CAUTION

!

1

Side Cover-L

Side Cover-R

Filter Cover

Aluminum Case

Screw

Screw

PCB unit

Hinge

Hinge

Leading edge

Leading edge

<Top view>

torque

0.5 Nm

Infrared Beam

Infrared Beam

Hinge

2

Power supply ( AC/DC 12

24[V] )

Relay Output ( Common )
Relay Output1
Relay Output 2(Another PCB Unit Output)
TEST Input ( - )
TEST Input ( + )

2
3
4

1

5
6
7

1

7

PCB unit

Note

Wires to

the controller

Jamb Hole

Cover A

Wire Sheath

Wire size

0.15 to 3.5 [mm

2

]

Screw (3×10 [mm])

Jamb Hole

Cover B

Push SW

Angle Stabilizer

PCB Holder

PCB unit

PCB unit Assembly

LEADING 

EDGE

MARK

LEADING EDGE MARK

LEADING EDGE MARK

Unit : [mm]

390

390

DOORSS1023T

3-

φ

3,5

Screws

Joint

6

Be careful not to drop the sensor, during transportation and installation. It may cause the sensor to break.

Fix the Aluminum Case to the door with 

Screws.

Front view of PCB unit

Dip SW

Terminal Block

Operation LED

Communication Cable

(4)

4.  Dip Switch Settings

PCB unit

=

4.1 TEST Input

2

1

3 4 5 6 7 8

To avoid dangerous door movements,

configure the DIP-SW settings of the sensor

before powering up the sensor.

When connected to a door controller without a

TEST input, set to “A”. When connected to a

door controller with a TEST input, set to “B”

Refer to [6.Timing Chart of events].

When two DOORSS's are installed in close proximity ,

optical cross interference between DOORSS's might 

cause mis-operation. To avoid this , different frequency

settings should be selected using DIP Switch #2.

 

1

A

Senza TEST

Con TEST

0v

B

Senza TEST

0v

B

A

Set to “B” to comply with EN16005

4.2 Optical Interference

DOORSS

DOORSS

A

2

B

2

2

1

3 4 5 6 7 8

4.5 Detection Range

4.3 Relay Output Mode

Refer to [6. Timing chart of events]

for full details on Relay Output Mode.

3

NO

NC

2

1

3 4 5 6 7 8

3

Set Non-Detection

distance 

A

2

1

3 4 5 6 7 8

5. Detection Angle Adjustment

Angle Stabilizer

PCB unit

5

The detection angle can be adjusted between 5

25 [deg] in 5 [deg] increments using the Angle Stabilizer.

Example) Changing angle from 5°

 

to 25° 

Side View

5

25

20

15

10

1.

(1)Lift

(3)Rotate PCB unit

(4)Slide Back

(2)Slide

2.

3.

25

2

1

3 4 5 6 7 8

6 7

50 mm

100 mm

150 mm

200 mm

250 mm

300 mm

400 mm

500 mm

Check that the detection area position conforms to EN16005

5

EN16005

Check that the detection

range conforms to EN16005

EN16005

EN16005

8

6

7 8

6

7 8

6 7 8

6 7 8

6 7 8

6

7 8

6

7 8

Door Leaf

Detection

Non-Detection

A

4.4 Masking detecting 

spots

4 5

1

2

3

4

5

6

spots

spots

spots

spots

4 5

1

2

3

4

5

-

4 5

1

2

3

4

-

-

4

5

1

2

3

-

-

-

3.6.1

Option 1: Plan View of SSS-5 Installation

(PCB units on both sides of the door wired back to the Door Controller independently)

PLAN VIEW and Wiring

Wire Sheath

Door Controller

Door Controller

Hinge

Hinge

Jamb Hole Cover

Jamb Hole Cover

Leading

Edge

Leading

Edge

Extra Wire Hole through the door

Connector 6P

Unità PCB 1

Unità PCB 2

7P Terminal stand

Unused

7P Terminal stand

PCB units are connected to each other

using the Communication Cable 

(supplied)

Slide SW

OFF

Hole( 

 φ10) drilled through the 

door.

3.6.2

Option 2: Plan View of SSS-5 Installation

(PCB units connected using Communication Cable and only 1 PCB units is wired back to the Door Controller)

ON

OFF

OFF

Note: 

Remember to set the Slide SW as indicated

Default Setting

BORDOD

I

CHIUSURA

Slide SW

User Manual (Original)

DOORSS

Safety Sensor for 

Swing Doors

The DOORSS is a microprocessor controlled active infrared presence detector for swing doors.

- 6 detection spots per PCB unit provide a wide detection area.

- The detection distance to the floor is set automatically by pressing a Push Switch.

- The detection range can be adjusted manually, using dip switches in increments of 50mm

- The relay output can be changed from NO to NC using a dip switch.

- Self diagnostic and monitoring functions are implemented.

The illustration below shows the standard configuration of DOORSS with one PCB units.

Table.1 Information of DOORSS 

!

COMPLIED STANDARDS

DIN18650-1:2010

EN 12978:2003 +A1:2009

EN16005:2012

EC type examination

44 205 13738001

Disregarding this symbol may result 

in serious injury or death

Special attention is required when 

this symbol is shown

Disregarding this symbol may result 

in injury or damage to equipment

Setting required to conform with EN16005

Drill fixing holes as illustrated 

below. When installing the 

DOORSS on both sides of the 

door it may be necessary to drill 

a wiring hole through the door. 

(Ref. 3.6 Plan View of DOORSS 

Installation)

Drilling may cause Electric shock! When drilling, pay attention to 

hidden wires.

Unscrew the Side Covers and remove the Filter 

Cover.

Remove the PCB Unit. Loosen the Screw on the PCB Holder and slide it 

aside to remove the PCB Unit.

When replacing the PCB unit it is very important that the side with "LEADING EDGE" marked on it is inserted

so that it is closest to the leading edge of the door. This will ensure maximum pedestrian safety at the door 

edge.

Remove the Terminal Block from the PCB unit.

Insert the PCB unit into the Aluminum Case, making sure that the 

side marked “LEADING EDGE” is closest to the leading edge of the 

door.

Attach the Angle Stabilizer and tighten the screws on the PCB 

Holders.

Remove Angle Stabilizer.

1)Lift and slide the Angle Stabilizer to the side as indicated.

2)Push the Angle Stabilizer with your thumb to remove it from 

the Aluminum Case.

Leading Edge

Leading Edge

PCB unit

Hinge

PCB Unit 2

7P Terminal 

stand

PCB Unit1

7P Terminal

stand

S-10DOORSS340 / DOORSS1023T

S-10DOORSS340

0

2

340

1

S-10DOORSS1023T

2

3

1023

3

DOORSS340 

2-

φ

3.5 Screw holes

200