17
D705M
3
On
during opening, the photocell cuts in to stop the gate until the obstacle is removed.
When the obstacle is removed the gate resumes opening;
Off
during opening, the photocell does not cut in.
4
On
NO-REVERSE function activated; the gate ignores the closure commands during
opening and reversal of movement occurs only during closure;
Off
the open-close pushbutton reverses the direction of movement of the gate even while
it is opening.
5
On
ENCODER enabled: encoder obstacle detection function activated (use the trimmer
FR to adjust the sensitivity to obstacles);
Off
ENCODER disabled;
6
On
pre-flashing and “photocell test” function enabled;
Off
pre-flashing and “photocell test” function disabled;
N.B.: to be used when the pho-
tocells are not used.
7 - 8
2nd RADIO CHANNEL operation (terminals no. 18 - 19)
Dip 7 Dip 8 Function
Off
Off
Gate contact open:
The contact activates on opening the gate and remains
active during the open time, during the TCA and during reclosure. It deacti-
vates once the gate has completed its closure movement.
Off
On
Bistable function active:
the radio control impulse causes the contact to
activate and remain active until the subsequent impulse.
On
Off
Monostable function active for 2 sec.:
the radio control impulse causes the
contact to activate and remain active for 2 sec.
On
On
Monostable function active for 180 sec.:
the radio control impulse causes
the contact to activate and remain active for 180 sec.
9
On
braking enabled;
Off
braking disabled;
Note: the braking system activates whenever the motor must stop (CLS - OLS - STOP
– change of direction) and reduces the inertia accumulated by the gear motor during
movement.
10
On
Man Present; the automation system will continue to open or close as long as the
OPEN or CLOSE buttons are held down. The gear motor will stop when the button
is released;
Off
normal (or pulse); when the OPEN, CLOSE or the PP button is pushed, the automatic
system performs a complete opening or closing manoeuvre;
Note: in the Man Present mode, the PP input (n° 12) is disabled, as is the radio receiver.
J1 jumper inserted:
resistive sensitive edge;
jumper not inserted:
fixed edge with NC contact.
ADVANCED FUNCTIONS
Clock function:
a timer can be connected to the open-close pushbutton in order to keep the
gate open at certain times during the day, after which it reverts to automatic closing.
The gate remains open as long as the Op/Cl input continues to be activated.
“Gate open contact” function:
when dipswitch 7 and dipswitch 8 are set to OFF, the second
radio channel (terminals no. 18 - 19) will act as a voltage-free contact to indicate when the gate
is open. This function can be used to connect “ZONE LIGHTING” or as a gate open indicator.
ENGLISH