UP050-EN Nozzle FN-1024&FN-1029_Instructions_rev3.docx
Page 3/5
4. Inspect the splashguards, scarves, grip covers, and confirm that there are not damages and intense dirt.
Carry out replacement if abnormality is discovered.
Trouble Shooting
Problem
Solution
Nozzle keeps tripping off immediately.
1. The sensor or the air passage on the nozzle spout may be
blocked by an alien substance or fuel. Remove the alien
substance or fuel and fill again.
2. The safety cut out attitude valve may operate with some
near horizontal fill pipes. Turn the nozzle spout downward
and fill again.
3. Some filler necks are difficult to refuel.
Slow down fuel delivery. Put on low latch position.
Nozzle fails to open.
1. Pump pressure is not added to the nozzle. Check the pump
and solenoid valve.
2. The passage in the nozzle is clogged up.
Replace or clean the nozzle.
3. Confirm whether nozzle lever was damaged.
In the case of damage, change the lever.
Nozzle does not close automatically
Stop use promptly.
Call your service contractor for repair or replace the nozzle.
Nozzle leaks.
Stop use promptly.
Call your service contractor for repair or replace the nozzle.
Guarantee
TATSUNO guarantees against defective materials and manufacturing during warranty period.
Warranty period: One year from date of supply.
If the delivery date cannot be established, the date code on the nozzle prevails.
Warranty does not cover below.
(1) Damage to the nozzle & swivel in an accident etc.
(2) Damage by natural disasters, such as a typhoon and an earthquake.
(3) Wear items such as spouts, vapour recovery boots, scarves or grip covers.
Replacement period
Nozzles are expendables. Even if there is no abnormality, we recommend replacement after use of
the nozzle & swivel for three years or the quantity of refuelling 2,500,000L.