background image

User Installation Manual 

r1.9-3/11/15

     

 

 

SmartAire

®

 MZ

 

 

 

 

7510 Montevideo Road 

© 2014 Tate Access Floors, Inc.  

Jessup, MD 20794 

 

 

Tel (410)799-4200 

1 of 26 

 

 

 

SmartAire

®

 MZ 

User Installation Guide 

 

 

Please Read and Save 

These Instructions 

Summary of Contents for SmartAire MZ Basic

Page 1: ...allation Manual r1 9 3 11 15 SmartAire MZ 7510 Montevideo Road 2014 Tate Access Floors Inc Jessup MD 20794 Tel 410 799 4200 1 of 26 SmartAire MZ User Installation Guide Please Read and Save These Inst...

Page 2: ...ttach the Sensors to the Rack Face 8 Step 4 Connect the Sensors to the Tree 9 Step 5 Connect the Tree to the SmartAire MZ 9 Step 6 Turn the Battery On 10 Step 7 Connect the Power to the SmartAire MZ 1...

Page 3: ...complete All work conducted on units should only be conducted by a trained professional Modifying equipment other than in ways suggested and approved by Tate are not recommended or supported and may d...

Page 4: ...i recommand ni support et peut endommager l quipement ou causer un pr judice Il est recommand que la batterie est test chaque ann e pour assurer le bon fonctionnement et l exploitation s curit int gr...

Page 5: ...EE 802 3af Power available at PD 12 95 W Maximum power delivered by PSE 15 40 W Voltage range at PSE 44 0 57 0 V Voltage range at PD 37 0 57 0 V Maximum current 350 mA Maximum cable resistance 20 Cate...

Page 6: ...ual r1 9 3 11 15 SmartAire MZ 7510 Montevideo Road 2014 Tate Access Floors Inc Jessup MD 20794 Tel 410 799 4200 6 of 26 QUICK INSTALLATION ALUMINUM DIRECTAIRE CABINET FACE QUICK INSTALLATION STEEL DIR...

Page 7: ...nit and all accessories Prepare zip ties and associated mounting hardware available nearby Prepare the DirectAire or DirectAire Al Panel and Installation Location HANDLE UNIT WITH CARE DO NOT MANUALLY...

Page 8: ...e corresponding zone of the SmartAire 2 and the rack Zone 1 is the bottom of the rack and Zone 4 is the top of the rack Zip ties can be used to assist in mounting the sensors The sensor face should be...

Page 9: ...MZ Though the hole in the floor where the SmartAire is to be installed Connect the temperature tree into the SENSOR PORT The Sensor will only connect in one orientation with 1 And 8 on the top of the...

Page 10: ...ors Inc Jessup MD 20794 Tel 410 799 4200 10 of 26 STEP 6 TURN THE BATTERY ON Switch the Battery backup to the ON Position IT IS NECESSARY TO HAVE THE BATTERY IN THE ON POSITION DURING NORMAL OPERATION...

Page 11: ...s the preferred option for powering the SmartAire Unit For redundant installation both the PoE and DC Coaxial supply can be provided but this is not necessary Once power is supplied to the unit it wil...

Page 12: ...en Retighten the screws down to lock them in position A MANUAL PHILIPS HEAD SCREWDRIVER OR A TORQUE LIMITING ELECTRIC SCREW DRIVER IS BEST FOR THIS PORTION OF THE INSTALLATION TO AVOID OVER TORQUING D...

Page 13: ...display should be mounted in the orientation that it fits on the edge meant to go Towards the rack it is cooling Hand Screw in the four 5mmx 5mm Screws Confirm SmartAire MZ is mounted to DirectAire Al...

Page 14: ...e left and right parallel stringers to the face of the rack Safely lower the fully extended SmartAire onto the stringer hangers you may need to slightly tilt the hangers inward to connect it perfectly...

Page 15: ...n top of the preinstalled SmartAire MZ on hangers The DirectAire should rest just above the SmartAire and not apply any force to the SmartAire If this is not the case please contact Tate for assistanc...

Page 16: ...h mode is currently active press again while the display is flashing to cycle through the mode options Quad zone Mode All four zones operate independently with high speed PID loops calculating current...

Page 17: ...button C Pressing this button once will convert the interface to Celsius Pressing the button once more will convert the unit back into Fahrenheit DISABLING UNOCCUPIED ZONES 5 Zone Disabling Buttons E...

Page 18: ...NU AVANC PEUT ALT RER DE MANI RE SIGNICANTE LA FONCTION DO L UNIT SMARTAIRE TATE NE RECOMMANDE PAS DO MODIFIER LES VALEURS DANS LA PROGRAMMATION AVANC E SUR LES UNIT S ACTIVEMENT ENGAG DANS LE REFROID...

Page 19: ...indow each with a specific IP and MAC Address Each line represents one SmartAire unit Note that SmartAire MZ requires connection to a dynamic DHCP network 6 Double Clicking on the line will force the...

Page 20: ...c E mail Configuration Interface to configure email alerts for errors The user can configure a custom Gmail account to originate all alerts from SmartAire MZ must have access non firewalled access to...

Page 21: ...Value 0 0 100 T3_Min Override Minimum Possible Value 0 0 100 T4_Min Override Minimum Possible Value 0 0 100 T1_Max Override Maximum Possible Value 100 0 100 T2_Max Override Maximum Possible Value 100...

Page 22: ...lso create an audible alarm if any of these conditions have caused failure T2_Fail Zone Failure 0 0 4 T3_Fail Zone Failure 0 0 4 T4_Fail Zone Failure 0 0 4 Board OFF ON 0 off 1 on 0 0 1 This value tur...

Page 23: ...3 6 1 4 1 43431 1 3 2 0 OctetString SMARTAIREMZ Read_ERORSTATE_T4 0 Read_ERORSTATE_T4 0 1 3 6 1 4 1 43431 1 3 22 0 Integer Pass 0 Read_ERORSTATE_T3 0 Read_ERORSTATE_T3 0 1 3 6 1 4 1 43431 1 3 21 0 Int...

Page 24: ...tAire Aluminum SA P SmartAire DirectAire Aluminum SA P SmartAire DirectAire Aluminum POE Injector Switch 802 3af 4 Probe Temperature Sensor Ethernet CAT5 Cables 1 Unit Per SmartAire Rack Rack Rack Rac...

Page 25: ...t cycle This will reset all parameters SNMP settings and TCP IP configurations and restore the unit to its default settings The unit will reboot after a 5 second delay upon completing this action WARN...

Page 26: ...ire mz or contact Tate Technical support for warranty terms and support Alarm Index Note All alarm conditions will cause SmartAire MZ to react by sounding an alarm opening all zones fully and re enabl...