TATA Motors Aquatermic Operation Manual Download Page 14

13

The following pages will appear: 

TIME

TIMER

WEEKLY  SCHEDULE

SCHEDULE

2/2 

NO. START 

00:00 

END MODE  TEMP 

HEAT 
HEAT 

0ºC 
0ºC 

00:00 

00:00 

00:00 

SCROLL 

SCHEDULE

TIME

TIMER

SCROLL 

SET 

ENTER 

WEEKLY  SCHEDULE

OK 

MON   TUES  WED   THUR   FRI

   SAT   SUN 

CANCEL 

Use ''

''

''

''

''

''

''

'' to scroll and adjust the time ,the mode 

and the temperature. Timers can be set, including start time and end 
time,mode and temperature. The mode includs heat mode, cool 
mode and DHW mode. 

The setting method reffer to timer setting. The end time must be later  
than the start time.Otherwise this will show that 

Timer is of no effect

Cancel the schedule: First select the days of the week. 
Use ''

''

''

''to scroll. 

Use ''

''

''

''to move to ”CANCEL”, press "OK" to cancel the 

schedule.If you want to exit WEEKLY SCHEDULE,press “BACK”. 

6.4.3  TIME

The TIME function is used to set the local actual time and date. 

Go to ''MENU''>''SCHEDULE''>''TIME''. Press ''OK''. The following  
page will appear: 

Use ''

''

''

''

''

''

''

'' to scroll and Use ''

'' 

''

'' adjust the 

time and date.  

TIMER

WEEKLY  SCHEDULE

SCHEDULE

12

30

01-01-2015

SCROLL 

TIME

CURRENT TIME

CURRENT DAY

You have to reset TIMER/WEEKLY SCHEDULE, if you change 
the MAIN page to the ROOM page or you change the ROOM 
page to the MAIN page.
The TIMER or WEEKLY SCHEDULE is invalid, if ROOM 
THERMOSTAT is effect.

INFORMATION

The ECO or COMFORT MODE has the highest priority, the TIMER

or WEEKLY SCHEDULE has the second priority and the PRESET 
TEMP. or WEATHER TEMP. SET has the lowest priority.

The PRESET TEMP. or WEATHER TEMP. SET becomes invalid,

when we set the ECO or COMFORT valid. We must reset the 
PRESET TEMP. or WEATHER TEMP. SET when we set the ECO or 
COMFORT invalid.

TIMER or WEEKLY SCHEDULE is not affected when ECO or

COMFORT is valid. TIMER or WEEKLY SCHEDULE is activated 
when the ECO or COMFORT is not running.

TIMER and WEEKLY SCHEDULE are at the same priority.  The

after setting function is valid.  The PRESET TEMP. becomes invalid 
when TIMER or WEEKLY SCHEDULE is valid. The WEATHER 
TEMP. SET is not affected by the setting of TIMER or WEEKLY 
SCHEDULE.

PRSET TEMP. and WATHER TEMP.SET are at the same priority.

The after setting function is valid.

INFORMATION

All about the time set items(PRESET TEMP. 

ECO/COMFORT

DISINFECT

 DHW PUMP

 TIMER

 WEEKLY SCHEDULE

 

SILENCE MODE 

HOLIDAY HOME), the ON/OFF of the 

corresponding function can be activated only when the start time or 
the end time.

INFORMATION

How to cancel the WEEKLY SCHEDULE 

6.5.1 Silent Mode 

The SILENT MODE is used to decrease the sound of the unit. 
However, it also decreases the heating/cooling capacity of the 
system. There are two silent mode levels. 
level2 is more silent than level1

,

and the heating or cooling capacity 

is also more decreasing. 
There are two method to use the silent mode: 
1) silent mode in all time;
2) silent mode in timer.

Go to the home page to check if silent mode is activated. If

is displayed, If the silent mode is activated,     will display on the home 

page. 

Go to ''MENU'' > ''OPTIONS'' > ''SILENT MODE''. Press ''OK'' .

The following page will appear: 

6.5 Options

OPTIONS menu contents as following: 
1)

SILENT 

MODE

2)

HOLIDAY 

AWAY

3)

HOLIDAY 

HOME

4)

BACKUP 

HEATER

TIME

TIMER

WEEKLY  SCHEDULE

SCHEDULE

1/2 

NO. START 

03:00 
06:00 


09:00 

END MODE  TEMP 

HEAT 

COOL 

HEAT 

HEAT 

30ºC 
20ºC 
35ºC 

32ºC 

00:00 

04:00 
08:00 

10:00 

02:00 

SCROLL 

Summary of Contents for Aquatermic

Page 1: ...OPERATION MANUAL Thank you very much for purchasing our product Before using your unit please read this manual carefully and keep it for future reference Central Heat Pump Heater Wire Controller...

Page 2: ...peratures DANGER RISK OF ELECTROCUTION Indicates a situation that could result in electrocution CAUTION Indicates a situation that could result in minor or moderate injury WARNING Indicates a situatio...

Page 3: ...oiler is activated A malfunction occured Silent mode is activated The disinfect function is activated Holiday away home is activated Backup heater is activated The compressor is activated Desired temp...

Page 4: ...m has the function including floor heating and domestic hot water The page will appear FHL1FHL2 FHLn SV2 UI SV1 TANK 55 C 27 SET C ON ON DHW ROOM 21 55 08 08 2015 SAT home page1 If the WATER FLOW TEMP...

Page 5: ...home page4 Main page FHL1FHL2 FHLn FCU1FCU2 FCUn SV2 UI ADDITION PAGE 21 55 08 08 2015 SAT ON ROOM 21 55 08 08 2015 SAT ON MAIN MAIN PAGE ADDITION PAGE TANK C 12 SET C ON ON DHW MAIN 21 55 08 08 2015...

Page 6: ...n will disappear the interface can be controlled 5 2 Turning ON OFF controls The ON OFF of the unit can be controlled by the interface if the ROOM TEHERMOSTAT is NON see ROOM THERMOSTAT SETTING on INS...

Page 7: ...e by the room thermostat CONFIRM OK 2 When the cursor is on DHW operation mode Press ON OFF key to turn on off the DHW mode TANK C 12 SET C ON ON DHW MAIN 21 55 08 08 2015 SAT A 55 TANK C 12 SET C OFF...

Page 8: ...Then the space operation mode is Always heat mode heat Always cool mode cool auto A Automatically changed by the software based on the outdoor temperature and depending on installer settings also the...

Page 9: ...30 35 C 00 00 25 C 00 00 25 C 2 3 1 when the space operation mode is changed the PRESET TEMP is off automatically The PRESET TEMP function can be used in the heat mode or cool mode But if the operatio...

Page 10: ...ll appear Press ON OFF The following page will appear PRESET TEMPERATURE PRESET TEMP OFF WEATHER TEMP SET ECO MODE HEAT MODE LOW TEMP ON OFF ON OFF 6 3 Domestic Hot WATER DHW 6 3 1 Disinfect DHW mode...

Page 11: ...is required and the heat pump system is operating for cooling or heating however there still is a demand from the hot water TANK HEATER function can be used to heat the water in tank Also even if the...

Page 12: ...NO START 06 00 00 00 00 00 2 3 00 00 4 1 NO START 00 00 00 00 00 00 6 7 00 00 8 5 DIS INFECT FAST DHW TANK HEATER DHW PUMP DOMESTIC HOT WATER DHW SCROLL 2 2 NO START 06 00 00 00 00 00 10 11 00 00 12 9...

Page 13: ...tion is on the timer is off the later setting is effective If the Timer is activated is displayed on home page Move to press OK to select or unselect the timer is selected the timer is unselected six...

Page 14: ...ust reset the PRESET TEMP or WEATHER TEMP SET when we set the ECO or COMFORT invalid TIMER or WEEKLY SCHEDULE is not affected when ECO or COMFORT is valid TIMER or WEEKLY SCHEDULE is activated when th...

Page 15: ...EATER OPTIONS CURRENT STATE SILENT LEVEL TIMER ON ENTER SILENT MODE SCROLL ADJUST If the silent TIMER is selected Press OK to enter the following page will appear HOLIDAY AWAY HOLIDAY HOME BACKUP HEAT...

Page 16: ...nly ROOM heat mode enabled Use ON OFF to select OFF or ON and use to scroll and adjust If the CURRENT STATE is OFF the HOLIDAY HOME is OFF If the CURRENT STATE is ON the HOLIDAY HOME is ON Use to adju...

Page 17: ...ER OK PARAMETER SERVICE INFORMATION SERVICE CALL LANGUAGE BACKLIGHT BUZZER SCREEN LOCK TIME EN ON ON 120SEC ERROR CODE SCROLL ENTER OK PARAMETER DISPLAY Use OK to enter and use to scroll Press OK the...

Page 18: ...ON PARAMETER P2 COMP PRESSURE2 kPa POWER CONSUMPTION OKWH SCROLL 5 5 OPERATION PARAMETER T1B LEAVING WATER TEMP 2 25 C 30 C T2 PLATE F OUT TEMP 45 C T2B PLATE F IN TEMP 7 C T3 OUTDOOR EXCHANGE TEMP 7...

Page 19: ...NT STATE SILENT LEVEL TIMER HOLIDAY AWAY CURRENT STATE DHW MODE DISINFECT HEAT MODE FROM UNTIL HOLIDAY HOME CURRENT STATE FROM UNTIL SCHEDULE DISPLAY LANGUAGE BACKLIGHT BUZZER SCREEN LOCK TIME TIME CU...

Page 20: ...36 35 35 34 34 33 33 32 32 31 31 30 30 30 7 T1S 40 40 39 39 38 37 37 36 36 35 35 34 34 33 33 32 32 31 31 30 30 8 T1S 41 41 40 40 39 38 38 37 37 36 35 35 34 34 33 32 32 31 31 30 30 20 T4 20 19 18 17 16...

Page 21: ...25 21 18 14 T4 10 T4 15 15 T4 22 22 T4 30 30 T4 46 1 T1S 20 18 18 18 T4 10 T4 15 15 T4 22 22 T4 30 30 T4 46 2 T1S 21 19 18 18 T4 10 T4 15 15 T4 22 22 T4 30 30 T4 46 3 T1S 22 20 18 18 T4 10 T4 15 15 T...

Page 22: ...31 30 30 30 30 30 30 30 30 30 30 30 8 37 36 35 35 34 34 33 33 32 31 31 31 30 30 30 30 30 30 30 30 Table6 The environment temperature curve of the high temperature setting for ECO mode T4 20 19 18 17 1...

Page 23: ...MD15I 003DW L201612120004 16127400A01835...

Reviews: