background image

Mechanical Structures and Installations

23

mm

170

mm

50

mm

 Comply with the DMX512 standard protocols. 

 Digital numeric display, set DMX decode start address by buttons.

 RDM function can realize intercommunication between 

   DMX master and decoder. For example, 
   DMX decoder address can be set by DMX master console.

 PWM frequency 2000/500Hz selectable.

 Logarithmic or linear dimming curve selectable.

 Stand-alone RGB mode and 3 channel dimmer mode selectable,

   which be controlled by buttons with built-in programs, instead of DMX signal.

 

Over-heat / Short circuit protection, recover automatically. 

D

+

D

-

D

-

D

+

DM X 
M as ter

A C 1 0 0 -2 4 0 V

P ow er S upply
1 2 -2 4 VDC
C ons tant Voltag e

R G B L ED s tri p

Output type

Constant voltage

Output power

3 x (72-144)W

Output voltage

3 x (12-24)VDC

Output current

3CH,6A/CH

Input voltage

12-24VDC

Input current

18.5A

User Manual Ver 1.0.7         

Technical

 

Parameters

Input a nd O utput

Warranty a nd P rotec ti on

 5 years

Protection

Reverse polarity

Over-heat    
Short circuit 

  Warranty

Operation

 

temperature

Case

 

temperature

 

(Max.)

Envi ronm ent 

IP

 

rating

IP20

  

Ta: -30

O

C ~ +55

O

C

T

 

c:

 

+85

O

C

Model No.: D3-L

Features

Page 1

Mechanical Structures and Installations

RDM/Stand-alone function/Two PWM frequency/Linear or logarithmic dimming/Numeric display

3 C hannel C ons tant Voltag e D M X5 1 2 & R DM D ec oder 

D3-L    3 Channel Constant Voltage DMX512 & RDM Decoder 

D

+

D

-

D

-

D

+

DMX input +

DMX input -

DMX output -

DMX

GND/Power input - 

Power input -

Power input +

Power input +

Output LED +

Output LED +

Output LED +

Output Red LED - 

Output Green LED - 

Output Blue LED - 

Setting key

LVD

Digital display

Wiring Diagram

Installation rack

S afety a nd E M C

EMC standard (EMC)

Certification

CE,EMC,LVD

Safety standard(LVD)

EN55032:2015,
EN61000-3-2:2014,
EN61000-3-2:2013,
EN55024 :2010/A1:2015
EN 61347-1:2015
EN 61347-2-11:2015

Note: 

1. An DMX signal amplifier is needed if more than 32 decoders are connected, or use overlong signal line, 
    signal amplification should not be more than 5 times continuously.
2. If the recoil effect occurs because of longer signal line or bad line quality, please try to connect 0.25W 
    90-120

Ω

 

terminal resistor at the end of each DMX signal line.

Wei g ht

 0

.

100

kg

Gross weight

  Net weight

 0

.

122

kg

Wiring Diagram

23

mm

170

mm

50

mm

 Comply with the DMX512 standard protocols. 

 Digital numeric display, set DMX decode start address by buttons.

 RDM function can realize intercommunication between 

   DMX master and decoder. For example, 
   DMX decoder address can be set by DMX master console.

 PWM frequency 2000/500Hz selectable.

 Logarithmic or linear dimming curve selectable.

 Stand-alone RGB mode and 3 channel dimmer mode selectable,

   which be controlled by buttons with built-in programs, instead of DMX signal.

 

Over-heat / Short circuit protection, recover automatically.

 

D

+

D

-

D

-

D

+

DM X 
M as ter

A C 1 0 0 -2 4 0 V

P ow er S upply
1 2 -2 4 VDC
C ons tant Voltag e

R G B L ED s tri p

Output type

Constant voltage

Output power

3 x (72-144)W

Output voltage

3 x (12-24)VDC

Output current

3CH,6A/CH

Input voltage

12-24VDC

Input current

18.5A

User Manual Ver 1.0.7         

Technical

 

Parameters

Input a nd O utput

Warranty a nd P rotec ti on

 5 years

Protection

Reverse polarity
Over-heat    
Short circuit 

  Warranty

Operation

 

temperature

Case

 

temperature

 

(Max.)

Envi ronm ent 

IP

 

rating

IP20

  

Ta: -30

O

C ~ +55

O

C

T

 

c:

 

+85

O

C

Model No.: D3-L

Features

Page 1

Mechanical Structures and Installations

RDM/Stand-alone function/Two PWM frequency/Linear or logarithmic dimming/Numeric display

3 C hannel C ons tant Voltag e D M X5 1 2 & R DM D ec oder 

D3-L    3 Channel Constant Voltage DMX512 & RDM Decoder 

D

+

D

-

D

-

D

+

DMX input +

DMX input -

DMX output -

DMX

GND/Power input - 

Power input -

Power input +

Power input +

Output LED +

Output LED +

Output LED +

Output Red LED - 

Output Green LED - 

Output Blue LED - 

Setting key

LVD

Digital display

Wiring Diagram

Installation rack

S afety a nd E M C

EMC standard (EMC)

Certification

CE,EMC,LVD

Safety standard(LVD)

EN55032:2015,
EN61000-3-2:2014,
EN61000-3-2:2013,
EN55024 :2010/A1:2015
EN 61347-1:2015
EN 61347-2-11:2015

Note: 

1. An DMX signal amplifier is needed if more than 32 decoders are connected, or use overlong signal line, 
    signal amplification should not be more than 5 times continuously.
2. If the recoil effect occurs because of longer signal line or bad line quality, please try to connect 0.25W 
    90-120

Ω

 

terminal resistor at the end of each DMX signal line.

Wei g ht

 0

.100

kg

Gross weight

  Net weight

 0

.122

kg

Note:

1.   An DMX signal amplifier is needed if more than 32 decoders are connected, or use overlong signal line,

  signal amplification should not be more than 5 times continuously.

2.  If the recoil effect occurs because of longer signal line or bad line quality, please try to connect 0.25W

 90-120

Ω

 terminal resistor at the end of each DMX signal line.

Summary of Contents for LCDMXSD-D3-L

Page 1: ...splay set DMX decode start address by buttons RDM function can realize intercommunication between DMX master and decoder For example DMX decoder address can be set by DMX master console PWM frequency 2000 500Hz selectable Logarithmic or linear dimming curve selectable Stand alone RGB mode and 3 channel dimmer mode selectable which be controlled by buttons with built in programs instead of DMX sign...

Page 2: ... 2 4 0 V Pow er S upply 1 2 2 4 VDC C onstant Voltage RGB LED s trip Page 1 Mechanical Structures and Installations D3 L 3 Channel Constant Voltage DMX512 RDM Decoder D D D D DMX input DMX input DMX output DMX output GND Power input Power input Power input Power input Output LED Output LED Output LED Output Red LED Output Green LED Output Blue LED Setting key Digital display Wiring Diagram Install...

Page 3: ... 255 CH3 0 255 CH1 PWM 0 100 LED R DMX Console DMX Decoder Output CH2 PWM 0 100 LED G CH3 PWM 0 100 LED B Stand alone RGB Mode Enter stand alone RGB mode only when DMX signal is disconnected or lost Short press M key when display P01 P30 enter stand alone RGB mode Press or key to change dynamic mode number P01 P30 Each mode can adjust speed and brightness Long press M key for 2s prepare for setup ...

Page 4: ...number is 1 dimmer mode number is 1 disable automatic blank screen de Malfunctions analysis troubleshooting 1 Wrong connection of R G B wires 2 DMX decode address error Causes 1 Output cable is too long 2 Wire diameter is too small 3 Overload beyond power supply capability 4 Overload beyond controller capability Wrong colour Malfunctions Uneven intensity between front and rear with voltage drop No...

Reviews: