![Task Force Tips VIT Instructions For Installation, Safe Operation And Maintenance Download Page 6](http://html.mh-extra.com/html/task-force-tips/vit/vit_instructions-for-installation-safe-operation-and-maintenance_820913006.webp)
©Copyright Task Force Tips, Inc. 2009-2015
LIN-050 July 2, 2015 Rev01
6
5.0 FIELD INSPECTION
TFT’S VIT is designed and manufactured to be damage resistant and require minimal maintenance. However, as the primary fi re
fi ghting tool upon which your life depends, it should be treated accordingly.
WARNING
Nozzle must be inspected for proper operation and function according to the inspection checklist
in Section 6.0 before each use. Any nozzle that fails inspection is dangerous to use and must
be repaired before using.
Performance tests shall be conducted on the VIT nozzle after a repair, or anytime a problem is reported to verify operation in
accordance with TFT test procedures. Consult factory for the procedure that corresponds to the model and serial number of the
nozzle. Any equipment which fails the related test criteria should be removed from service immediately. Troubleshooting guides are
available with each test procedure, or equipment can be returned to the factory for service and testing.
Factory service is available with repair time seldom exceeding one day in our facility. Factory serviced nozzles are repaired by
experienced technicians to original specifi cations, fully tested and promptly returned. Any returns should include a note as to the
nature of the problem, who to reach in case of questions and if a repair estimate is required.
Repair parts and service procedures are available for those wishing to perform their own repairs. Task Force Tips assumes no liability
for damage to equipment or injury to personnel that is a result of user service.
CAUTION
Any alteration to the nozzle and its markings could diminish safety and constitutes a misuse of
this product.
All Task Force Tips nozzles are factory lubricated with high quality silicone grease. This lubricant has excellent washout resistance
and long term performance. If your department has unusually hard or sandy water, the moving parts may be affected. Foam agents
and water additives contain soaps and chemicals that may break down the factory lubrication.
The moving parts of the nozzle should be checked on a regular basis for smooth and free operation, and signs of damage.
IF THE
NOZZLE IS OPERATING CORRECTLY, THEN NO ADDITIONAL LUBRICATION IS NEEDED.
Any nozzle that is not operating
correctly should be immediately removed from service and the problem corrected.
6.0 INSPECTION CHECKLIST
Nozzle must be inspected for proper operation and function according to the checklist before each use. Check that:
1) There is no obvious damage such as missing parts, broken or loose parts, damaged labels, etc.
2) Coupling is tight and leak free
3) Valve handle moves freely through full range, and shuts off fl ow.
4) “OFF” position does fully shut off and fl ow is stopped.
5) Nozzle fl ow is adequate as indicated by the pump pressure and nozzle reaction.
6) Front end is tight and leak free
7) Thread protector fully retracts
WARNING
Any VIT nozzle failing any part of the inspection checklist is unsafe and must have the problem
corrected before use. Operating a nozzle that fails any of the above inspections is a misuse of
this equipment.
7.0 ANSWERS TO YOUR QUESTIONS
We appreciate the opportunity of serving you and making your job easier. If you have any problems or questions, our toll-free
“Hydraulics Hotline”, 800- 348-2686 or 1-219-462-6161 is normally available to you 24 hours a day, 7 days a week.