7.0 OPERATION

Figure 7.0

7.1 HOSE CONNECTION

Attach  inlet  fire  hose  to  the  coupling  on  the  inlet  end  of  the  PRO/pak.  Larger  hoses  may  be  used  with  an  adapter.  For  maximum

maneuverability, we recommend attaching 1” hose to the PRO/pak itself.

7.2 FILLING THE TANK

Unscrew the fill port lid by turning counterclockwise. Fill tank to bottom of fill port. Agent may seep out the vents if overfilled. Close the fill

port lid by turning clockwise.

7.3 CONNECTING DISCHARGE HOSE AND NOZZLE

The nozzle  may be attached  directly to  the quick-connect  fitting on the control  block  or to the  end  of the  outlet hose which is  then

attached to the control block. 

1. Align the marks on the quick-connect male fitting with the marks on the female fitting and push the two pieces together. 

2. Twist the nozzle or hose one quarter turn to the right to latch the quick-connect fitting.

3. To remove fan nozzle, remove set screw.

4. Hose lengths available. TFT part U-HS6, U-HS12, and U-HS25.

7.4 SETTING CONCENTRATION

Remove the nut on top of the percentage knob and lift the knob to select the proper foam concentrate type. Replace the knob nut. Turn

the knob to the desired concentrate percentage. The percentage knob may be turned to the OFF position for water only use. Be sure to

use the foam manufacturer’s recommended concentrate ratio.

7.5 CONTROLLING FLOW

Pressurize  the hose line. Turn  the flow control  valve  to start water flowing through the PRO/pak. Flow  may be reduced by partially

closing the control valve.

CAUTION

The PRO/pak’s eductor will not function if the back pressure from the outlet hose or nozzle is too

high. To reduce the risk of injury or death due to a non-functioning unit:

• Never use hose longer than the 25’ (7.5m) U-HS25 optional hose. 

• Never add additional hose, or use other manufacturer’s hose assemblies and nozzles. 

CAUTION

There  is  no  check  valve  in  the  PRO/pak  eductor  system.  Installing  a  shut  off  valve  between  the

PRO/pak  and  the  fan  nozzle  can  cause  the  agent  tank  to  fill  with  water  and  dilute  the  agent

concentrate resulting in ineffective agent. Never install a shut off valve between the PRO/pak and

the fan nozzle. 

k

a

p

/

O

R

P

k

a

p

/

O

R

P

PORTABLE MULTI PURPOSE FOAM SYSTEM

PATENT PENDING ó MODEL UM12

PUSH & TURN
TO ATTACH

CONTROL
FLOW

FILL
2.5 GAL

SELECTOR
WHEEL

CONNECT
SUPPLY

ADJUST %

START UP PROCEDURE

To Make Foam - Connect water supply. Attach the desired nozzle to 
the Quick-Connect. Turn the Percentage Knob to the desired 
percentage. Twist the Valve Handle to start water flow.

Summary of Contents for PRO/pak

Page 1: ...rvices personnel for firefighting All personnel using this equipment shall have completed a course of education approved by the Authority Having Jurisdiction AHJ This instruction manual is intended to familiarize firefighters and maintenance personnel with the operation servicing and safety procedures associated with this product This manual should be kept available to all operating and maintenanc...

Page 2: ...ghting IFSTA Principles of Foam Fire Fighting DANGER PERSONAL RESPONSIBILITY CODE The member companies of FEMSA that provide emergency response equipment and services want responders to know and understand the following 1 Fire ghting and Emergency Response are inherently dangerous activities requiring proper training in their hazards and the use of extreme caution at all times 2 It is your respons...

Page 3: ...pak is designed for Class A and Class B foam concentrates but it has been used with other concentrates for other uses If you intend to use the PRO pak for liquids other than Class A and Class B concentrates and water we urge you to contact the Task Force Tips Engineering Department The use of other liquids may void the warranty and subject the user to hazards not addressed in this manual The user ...

Page 4: ...0 23 2 3 0 3 2 US teaspoons 1 427 0 39 3 9 0 5 1 US tablespoon 1 256 0 50 5 0 0 64 1 1 4 US tablespoons 1 200 0 78 7 8 1 2 US tablespoons 1 128 1 0 10 1 3 2 1 2 US tablespoons 1 100 1 6 16 2 1 4 US cup 1 64 2 3 23 3 1 3 US cup 1 43 3 1 31 4 1 2 US cup 1 32 4 7 43 6 3 4 US cup 1 21 6 3 67 8 1 US cup 1 16 7 8 78 10 1 1 4 US cup 1 13 KEY Metering setting not compatible with PRO pak WARNING Agent conc...

Page 5: ...ce of the concentrate is suitable for the application In all cases follow the concentrate manufacturer s recommendation WARNING Agent concentrates can be ineffective if not used at the correct concentration ratio Ineffective agents can increase the potential for injury or death Ensure that the Percentage Knob is set to the correct concentration ratio for the type of agent being used prior to flowi...

Page 6: ...k of serious injury or death To reduce the risk Clean tank and agent passages thoroughly when changing agent types Check agent manufacturer s documentation for recommendations Always identify the contents of the reservoir per the agent manufacturer s Technical data Sheet NOTICE Components of the PRO pak may be subject to degradation including corrosion by harsh chemicals such as sodium hypochlorit...

Page 7: ...yer of drier foam is desired Figure 6 0A Piercing Nozzle is for use with Class A foam solutions in deep seated fires Foam expansion will be negligible It can be used where an application of solution is needed but the location is inaccessible The piercing nozzle is not designed to pierce metal and other hard objects To use behind hard surfaces punch a hole first Figure 6 0B Figure 6 0C Straight Str...

Page 8: ...ob nut Turn the knob to the desired concentrate percentage The percentage knob may be turned to the OFF position for water only use Be sure to use the foam manufacturer s recommended concentrate ratio 7 5 CONTROLLING FLOW Pressurize the hose line Turn the flow control valve to start water flowing through the PRO pak Flow may be reduced by partially closing the control valve CAUTION The PRO pak s e...

Page 9: ...the following is recommended While still connected to water supply remove Circle Cotters and Pull Pins Remove Control Unit from tank Attach the Cap directly to the Quick Connect on the Control Block Turn the valve halfway on until the discharge is agent free This will backflush a small amount of water through the agent passage Rotate the Percentage Knob back and forth to make sure all agent passag...

Page 10: ...sition 6 Install the Cap on the outlet of the Control Block 7 Turn the Flow Control valve until a trickle of clean water is flowing from the end of the Pickup Tube 8 Turn the Percentage Knob back and forth to make sure all agent passages are flushed 9 Shut off water and reinstall the Control Unit on the tank and insert the Pull Pins and circle cotters 10 Remove the Cap The exterior of the PRO pak ...

Page 11: ...rge of its obligations under this limited warranty If TFT makes this election claimant shall return the equipment to TFT free and clear of any liens and encumbrances This is a limited warranty The original purchaser of the equipment any person to whom it is transferred and any person who is an intended or unintended beneficiary of the equipment shall not be entitled to recover from TFT any consequ...

Page 12: ...RT LISTS Exploded View Drawings and Part Lists available at tft com serial number SYMPTOM POSSIBLE CAUSE REMEDY PRO pak will not make foam Out of agent Refill tank Percentage knob is in RINSE Select desired percentage Percentage know is plugged Remove screw on Percentage Knob inspect and clean holes in top of control block and agent passages in bottom of Percentage Knob Non standard outlet hose be...

Reviews: