background image

©Copyright Task Force Tips LLC 1999-2020

15

LIM-030 November 16, 2020 Rev15

Figure 4.5I

Figure 4.5J

Figure 4.5K

0

10

20

30

40

50

60

70

80

0

20

40

60

80

100

120

140

160

180

200

220

240

260

280

300

HORIZONTAL DISTANCE (FEET)

VE

R

T

IC

AL

 DIS

T

ANC

(FEET)

0

5

10

15

20

0

10

20

30

40

50

60

70

80

90

METERS

ME

TERS

MASTERSTREAM 2000, 100 PSI (7 BAR, 700 KPA)

A

B

C

D

E

GPM

 

LBS

 

 

  

LPM

 

KGF

CURVE

FLOW

 

REACTION

 

 

CURVE

 

FLOW

 

REACTION

A

300

 

150

 

 

A

 

1100

 

70

B

600

 

300

 

 

B

 

2300

 

140

C

1000

510

C

3800

230

D

1500

760

D

5700

350

E

2000

1010

E

7500

460

0

10

20

30

40

50

60

70

80

0

20

40

60

80

100

120

140

160

180

200

220

240

260

280

300

HORIZONTAL DISTANCE (FEET)

V

ER

T

IC

AL

 DI

ST

AN

CE

 (F

EET)

0

5

10

15

20

0

10

20

30

40

50

60

70

80

90

METERS

METERS

MASTERSTREAM 2000, 120 PSI (8.3 BAR, 830 KPA)

A

B

C

D

E

GPM

 

LBS

 

 

  

LPM

 

KGF

CURVE

FLOW

 

REACTION

 

 

CURVE

 

FLOW

 

REACTION

A

300

 

170

 

 

A

 

1100

 

70

B

600

 

330

 

 

B

 

2300

 

150

C

1000

550

C

3800

250

D

1500

830

D

5700

380

E

2000

1110

E

7500

500

CURVE

A
B
C
D
E

GPM

FLOW

600

1000

2000

3000

4000

LBS

REACTION

280

470

950

1400

1900

CURVE

A
B
C
D
E

LPM

FLOW

2300

3800

7600

11000

15000

KGF

REACTION

130

210

430

640

860

0

10

20

30

60

80

100

120

160

200

240

280

320

360

400

HORIZONTAL DISTANCE (FEET)

METERS

METERS

B

C

D

E

0

20

40

60

80

100

0

0

20

40

40

80

120

VERTICAL DIST

ANCE (FEET)

A

MASTERSTREAM 4000, 80 PSI (5.5 BAR, 550 KPA)

Summary of Contents for Masterstream Series

Page 1: ...his equipment shall have completed a course of education approved by the Authority Having Jurisdiction AHJ This instruction manual is intended to familiarize firefighters and maintenance personnel wit...

Page 2: ...vation Refer to LIM 030 and LIM 035 for effective stream trajectories of Task Force Tips Masterstream nozzles at 30 elevation This graph cannot be used to estimate maximum reach for elevation angles b...

Page 3: ...ices want responders to know and understand the following 1 Fire ghting and Emergency Response are inherently dangerous activities requiring proper training in their hazards and the use of extreme cau...

Page 4: ...hs WARNING This equipment is intended for use by trained personnel for firefighting Use of this equipment for other purposes may involve hazards not addressed by this manual Seek appropriate guidance...

Page 5: ...or long term installations it is recommended that the threads be greased before installing the nozzle AUTOMATIC SERIES FLOW RANGE NOMINAL PRESSURE STANDARD COUPLING GPM L min PSI BAR kPa 100 MASTERSTR...

Page 6: ...e with six different methods to move the stream shaper as shown Figure 3 1A Figure 3 1B Figure 3 1C Coupling Halo Ring Stream Shaper Bumper Stream Shaper moved manually by rotating the Halo Ring or Bu...

Page 7: ...lements are available from TFT item M160 Maximum hydraulic pressure is 1000 psi 70 bar 7000 kPa for Masterstream 1000 or 1250s 3 6 ELECTRIC INSTALLATION Nozzles with electric stream shaper actuation a...

Page 8: ...pical performance of this nozzle Figure 4 1A Figure 4 1B MASTERSTREAM 1000 PERFORMANCE 0 20 40 60 80 100 120 140 160 0 200 400 600 800 1000 1200 1400 1600 1800 2000 FLOW GPM PRESSURE PSI 0 2 4 6 8 10...

Page 9: ...ting Figure 4 2A Figure 4 2B Figure 4 2C MASTERSTREAM 1250 PERFORMANCE 0 20 40 60 80 100 120 140 160 0 200 400 600 800 1000 1200 1400 1600 1800 2000 FLOW GPM PRESSURE PSI 0 2 4 6 8 10 0 1000 2000 3000...

Page 10: ...TING 120 PSI SETTING 8 BAR 7 BAR 6 BAR TO ADJUST PRESSURE SETTING 1 LOOSEN BOTH SCREWS 2 ADJUST PRESSURE KNOB 3 LOCK KNOB BY TIGHTENING BOTH SCREWS UNTIL SNUG NOTE LOCKED KNOB SHOULD NOT ROTATE BY HAN...

Page 11: ...baffle is moved for example to flush the nozzle then the baffle must be readjusted to obtain the desired flow Refer to Figure 3 2 for baffle position to achieve a certain flow and pressure The figure...

Page 12: ...se the risk of injury due to exposure Care must be taken to avoid dents or nicks in the nozzle tip 0 0 10 10 20 20 30 40 50 60 70 80 0 0 20 10 40 20 60 30 80 40 100 50 120 60 140 70 160 80 90 180 200...

Page 13: ...0 140 160 180 200 220 240 260 280 300 HORIZONTAL DISTANCE FEET VERTICAL DISTANCE FEET 0 5 10 15 20 0 10 20 30 40 50 60 70 80 90 METERS METERS MASTERSTREAM 1250 120 PSI 8 3 BAR 830 KPA A B C D E GPM LB...

Page 14: ...0 140 160 180 200 220 240 260 280 300 HORIZONTAL DISTANCE FEET VERTICAL DISTANCE FEET 0 5 10 15 20 0 10 20 30 40 50 60 70 80 90 METERS METERS MASTERSTREAM 1500 120 PSI 8 3 BAR 830 KPA A B C D E GPM LB...

Page 15: ...0 60 80 100 120 140 160 180 200 220 240 260 280 300 HORIZONTAL DISTANCE FEET VERTICAL DISTANCE FEET 0 5 10 15 20 0 10 20 30 40 50 60 70 80 90 METERS METERS MASTERSTREAM 2000 120 PSI 8 3 BAR 830 KPA A...

Page 16: ...100 120 0 20 40 60 80 100 0 40 80 120 160 200 240 280 320 360 400 HORIZONTAL DISTANCE FEET A B C D E MASTERSTREAM 4000 100 PSI 7 BAR 700 KPA CURVE A B C D E GPM FLOW 600 1000 2000 3000 4000 LBS REACTI...

Page 17: ...is trapped in the nozzle 1 Shut off flow to the nozzle 2 Move the stream shaper to the wide fog position For Selectable Nozzles Turn flow selector on front to FLUSH position For Fixed Nozzles Remove n...

Page 18: ...Figure 5 2D CONTROL SPRING SHAFT POPPET CYLINDER RETURN SPRING PISTON MASTERSTREAM 1250 AND 1500 FRONT END PARTS RETURN SPRING CYLINDER SHAFT POPPET CONTROL SPRING PISTON MASTERSTREAM 2000 FRONT END...

Page 19: ...ion ratio is increased the reach of the nozzle will be decreased due to the greater amount of bubbles in the stream and their inability to penetrate the air The reach with foam is approximately 10 les...

Page 20: ...rge of its obligations under this limited warranty If TFT makes this election claimant shall return the equipment to TFT free and clear of any liens and encumbrances This is a limited warranty The ori...

Page 21: ...n be returned to the factory at any time for a complete checkup and re lubrication with silicone grease The field use of Break Free CLP spray or liquid lubricant will help to temporarily restore the s...

Page 22: ...5 Figure 8 1B Figure 8 1C Figure 8 1D MASTERSTREAM 1250 AND 1500 LUBE POINTS LUBE LUBE LUBE LUBE POPPET PISTON SHAFT SHAFT POPPET LUBE LUBE LUBE LUBE PISTON MASTERSTREAM 2000 FRONT END PARTS SHAFT POP...

Page 23: ...personnel that is a result of user service Contact the factory or visit the web site at tft com for parts lists exploded views test procedures and troubleshooting guides Performance tests shall be co...

Page 24: ...hrough full range 6 Shaper detent if so equipped operates smoothly and positively BEFORE BEING PLACED BACK IN SERVICE nozzles must be inspected to this checklist 1 All controls and adjustments are ope...

Reviews: