Task Force Tips Master Foam Series Instructions For Installation, Operation And Maintenance Download Page 3

©Copyright Task Force Tips LLC 2015-2020

3

LIZ-030 October 29, 2020 Rev13

SUPPORTING MATERIALS

The following documents contain supporting safety and operating 

information pertaining to the equipment described in this manual.

LIA-025

Manual: Foam Aspirators

©Copyright Task Force Tips, Inc. 2009 

LTT-135 July 28, 2009 Rev00

NOZZLE TRAJECTORY  

ELEVATION FACTORS

TASK FORCE TIPS, INC.

MADE IN USA • www.tft.com

3701 Innovation Way, Valparaiso, IN 46383-9327 USA

800-348-2686 • 219-462-6161 • Fax 219-464-7155

  1.0   To estimate elevation angle when vertical and horizontal distances to target are known:

   

1.1  Find the maximum height and reach at 30° from the appropriate trajectory curve in LIM-030 or LIM-035.

   

1.2  Calculate the Height Factor by dividing the vertical distance to the target by maximum height from step 1.1. 

   

1.3  Calculate the Reach Factor by dividing the horizontal distance to the target by maximum reach from step 1.1.

   

1.4  On the graph of nozzle trajectory elevation factors, plot the intersection of the Height Factor and Reach factor from steps 1.2 and 1.3. If this point lies  

   

   

on or between the curves given, estimate the appropriate elevation angle. If this point lies within the shaded region of the graph, then a higher 

ÀRZ

 or  

   

   

pressure must be used to reach the target.

 

2.0   To estimate maximum reach for a given elevation angle above 0°:

   

2.1  From the graph of nozzle trajectory elevation factors, choose the trajectory curve for the desired elevation angle.

   

2.2  Find the point where this trajectory curve intersects the height of discharge (zero height line).

   

2.3  Estimate the Reach Factor at this point using the scale across the top of the graph.

   

2.4  Multiply this Reach Factor by the reach at 30° elevation from the appropriate trajectory curve in LIM-030 or LIM-035.

 

3.0   To estimate maximum height for a given elevation angle above 0°:

   

3.1  From the graph of nozzle trajectory elevation factors, choose the trajectory curve for the desired elevation angle.

   

3.2  Find the maximum height on this trajectory curve.

   

3.3  Estimate the Height Factor at the maximum height using the scale on the left side of the graph.

   

3.4  Multiply this Height Factor by the height at 30° elevation from the appropriate trajectory curve in LIM-030 or LIM-035.

Stream reach and height at non-optimal elevations can be estimated as a factor of the performance at the optimal 30° elevation.

Refer to LIM-030 and LIM-035 for effective stream trajectories of Task Force Tips Masterstream nozzles at 30° elevation.

This graph cannot be used to estimate maximum reach for elevation angles below 30°.

-          

-45°

-          

-30°

-

-15°

-

15°

30°

45°

60°

75°

85°

-2.0

-1.5

-1.0

-0.5

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

1.1

Reach Factor (compared to 30° elevation)

Hei

ght Factor (compa

red to 30° elevation)

height of
discharge

IF TARGET IS IN THIS REGION, 

FLOW AND/OR PRESSURE MUST 

BE INCREASED.

TASK FORCE TIPS

ELECTRIC REMOTE NOZZLES

ELECTRIC REMOTE WIRING DIAGRAM

TASK FORCE TIPS LLC

3701 INNOVATION WAY, VALPARAISO, IN 46383-9327

(800) 348-2686  (219) 462-6161  FAX (219) 464-7155

MADE IN USA • TFT.COM

   

   

LESS ELABORATE WIRING

SYSTEMS MAY BE USED BY

ELIMINATING UPPER CONTROL

OR REMOTE CONTROL STATIONS

LIM-040 August 1, 2018 Rev05

©Copyright Task Force Tips LLC   1998-2018

LIM-040

ER Nozzle Wiring Guide

©Copyright Task Force Tips LLC  2008-2019 

LIY-500 April 8, 2019 Rev14

MANUAL: Remote Control (RC) 

Monitor Electrical Controls

Supplemental Instructions for use with RC Monitor Manual

INSTRUCTIONS FOR INSTALLATION, SAFE OPERATION AND MAINTENANCE

DANGER

Understand manual before use. Operation of this device without understanding the manual and 
receiving proper training is a misuse of this equipment. Obtain safety information at www.tft.
com/serial-number

TASK FORCE TIPS LLC

MADE IN USA • tft.com

3701 Innovation Way, IN 46383-9327 USA

800-348-2686 • 219-462-6161 • Fax 219-464-7155

SECTION 4.1

Monitor Mounted 
Operator Station

SECTION 4.2

Panel Mount 
Operator Station 
(Y4E-RP)

SECTION 4.3

Panel Mount With Display
Operator Station 
(Y4E-RP-D)

SECTION 4.4

Tethered 
Operator Station 
(Y4E-CT-##)

SECTION 4.5

Tethered Operator Station 
With Display 
(Y4E-CT-##-D)

SECTION 4.6

Wireless 
Operator Station 
(YE-RF-##)

SECTION 4.7

Wireless Operator Station 
With Display 
(YE-RF-##-D)

SECTION 3.0

SECTION 4.0

Electrical Controls Installation and Operation

SECTION 4.11

Monitor Position Display
(Y4E-DISP)

SECTION 4.12

Remote Auxiliary Function
Interface Control
(YE-REMAUX)

SECTION 4.13

Electric RC Monitor Aerial 
Truck Installation

SECTION 4.16

Electric Nozzle Actuator

SECTION 4.17

Valve Kits
(YE-VK-PH)

SECTION 5.0

Troubleshooting

SECTION 4.14

Multiplex Interface Control (YE-CAN#)

SECTION 4.15

Ethernet Interface Control

SECTION 4.9

Toggle Switch Monitor 
Operator Station  
(Y4E-TS)

SECTION 4.10

Monitor Communication 
Interface Control 
(Y4E-COMM)

SECTION 4.8

Joystick 
Operator Station 
(Y4E-JS)

LIY-500

Manual: Remote Control (RC) 

Monitor Electrical Controls

LTT-135

Nozzle Trajectory Elevation 

Factors

Summary of Contents for Master Foam Series

Page 1: ...t shall have completed a course of education approved by the Authority Having Jurisdiction AHJ This instruction manual is intended to familiarize firefighters and maintenance personnel with the operat...

Page 2: ...ment you may be called upon to use 3 It is your responsibility to know that you have been properly trained in Fire ghting and or Emergency Response and in the use precautions and care of any equipment...

Page 3: ...vation Refer to LIM 030 and LIM 035 for effective stream trajectories of Task Force Tips Masterstream nozzles at 30 elevation This graph cannot be used to estimate maximum reach for elevation angles b...

Page 4: ...OUPLINGS 3 5 ELECTRIC INSTALLATION 4 0 OPERATION 4 1 PATTERN CONTROL 4 2 FLUSHING DEBRIS 5 0 USE WITH FOAM 5 1 FOAM ASPIRATING ATTACHMENTS 5 2 CLEANING AFTER USE 5 3 SETTING FOAM PERCENTAGE 5 3 3 ORIF...

Page 5: ...capable of supporting the nozzle reaction force FLOW REACTION FORCE gpm l min Pounds Kilograms 250 950 132 60 350 1325 185 84 500 1900 265 120 750 2900 397 180 1000 3800 529 240 1250 4800 661 301 1500...

Page 6: ...ble 3 1 Figure 3 1A RANGE SMALL MEDIUM LARGE INLET COUPLING 2 5 65mm NH NPSH or BSP 3 5 89mm NH NPSH or BSP 3 5 89mm NH 4 0 100mm BSP RATED PRESSURE 100 psi 7bar 100 psi 7bar 100 psi 7bar FLOW RATING...

Page 7: ...s LLC 2015 2020 7 LIZ 030 October 29 2020 Rev13 Figure 3 1B Figure 3 1C Stream Shaper Baffle Foam Inlet Coupling Serial Number Folding Handles Orifice Plate Override Knob Masterfoam 1000 1250 1500 200...

Page 8: ...reach Range SMALL MEDIUM LARGE Nominal Flow 250 gpm 950 l min 350 gpm 1325 l min 500 gpm 1900 l min 750 gpm 2900 l min 1000 gpm 3800 l min 1250 gpm 4800 l min 1500 gpm 5700 l min 2000 gpm 7600 l min...

Page 9: ...e air Generally the straight stream reach with foam is approximately 10 less than with water only Actual results will vary based on brand of foam hardness of water temperature etc For specific informa...

Page 10: ...mply push it into the bore at the foam inlet on the nozzle The orifice plate has an O ring to hold it in place To remove the orifice plate hook a small object such as a screwdriver or Allen wrench int...

Page 11: ...BRATION 0 5 and 1 Class A foam of 20 centipoise viscosity 3 3M ATC 3 AR AFFF product code ATC 603 6 3M ATC AFFF product code FC 600F PERCENT 1000 and 1250 gpm Nozzles FOAM USED FOR CALIBRATION 1 Willi...

Page 12: ...20 40 60 80 100 120 140 160 180 200 220 A B A TFT MASTER FOAM B TFT MASTER FOAM WITH FOAMJET LX 3 or 1 FOAM AT 350 GPM AND 100 PSI Ver cal Distance Feet 0 10 20 30 40 50 60 70 Horizontal Distance Met...

Page 13: ...0 140 160 180 200 220 240 260 280 300 0 10 20 30 40 50 60 Horizontal Distance Meter Ver cal Distance Meter Horizontal Distance Feet Ver cal Distance Feet 3 or 1 Foam at 1000 GPM 100 PSI 0 10 20 30 40...

Page 14: ...ge of its obligations under this limited warranty If TFT makes this election claimant shall return the equipment to TFT free and clear of any liens and encumbrances This is a limited warranty The orig...

Page 15: ...mum of annually Units failing any part of this test must be removed from service repaired and retested upon completion of the repair 8 3 REPAIR Factory service is available with repair time seldom exc...

Page 16: ...low is adequate as indicated by pump pressure and nozzle reaction BEFORE BEING PLACED BACK IN SERVICE nozzles must be inspected to this checklist 1 All controls and adjustments are operational 2 There...