©Copyright Task Force Tips, Inc. 2002 - 2010
LKB-100 January 18, 2009 Rev9
8
5.1.2 METRIC TWISTER & BUBBLECUP FLOWS
19mm HOSE
FLOW
SETTING
30 Meters
60 Meters
90 Meters
10
24
40
10
24
40
10
24
40
PUMP
PRESSURE (BAR)
3.5
25
50
65
25
40
50
25
40
40
7
35
70
90
35
60
70
35
55
60
10
45
85
110
40
75
85
40
65
75
14
50
100
130
50
85
100
45
75
85
17
55
115
145
55
95
115
55
85
95
21
60
125
160
60
105
125
55
90
105
24
70
130
170
65
115
130
60
100
115
28
70
145
180
70
120
145
65
105
120
31
75
150
195
70
130
150
70
115
130
34
80
160
205
75
135
160
70
120
135
38
85
165
210
80
140
165
75
125
140
41
85
175
225
85
150
175
80
130
150
25mm HOSE
FLOW
SETTING
30 Meters
60 Meters
90 Meters
10
24
40
10
24
40
10
24
40
PUMP
PRESSURE (PSI)
3.5
25
60
95
25
60
85
25
55
85
7
40
85
135
40
85
125
40
80
115
10
45
105
165
45
100
150
45
100
140
14
55
125
195
55
115
180
55
115
165
17
60
135
215
60
130
195
55
130
180
21
65
150
235
65
145
215
65
140
200
24
70
165
255
70
155
235
70
150
215
28
75
175
275
75
165
250
75
165
230
31
80
185
290
80
180
265
80
170
245
34
85
195
305
85
190
280
85
180
255
38
85
205
320
85
195
290
85
190
275
41
90
210
335
90
205
305
90
195
285
38mm
HOSE
FLOW
SETTING
45 Meters
60 Meters
75 Meters
20
60
95
20
60
95
20
60
95
PUMP
PRESSURE (BAR)
3.5
55
150
220
55
150
210
55
145
205
5.2
65
185
270
65
180
260
65
180
250
7
75
210
310
75
210
300
75
205
290
8.6
85
240
350
85
235
335
85
230
320
10
90
260
380
90
255
365
90
255
355
12
100
285
415
100
275
395
100
275
380
14
105
305
445
105
295
425
105
290
410
15.5
115
320
470
115
315
450
115
310
435
17
115
335
490
115
335
475
115
325
460
45mm HOSE
FLOW
SETTING
45 Meters
60 Meters
75 Meters
20
60
95
20
60
95
20
60
95
PUMP
PRESSURE (BAR)
3.5
55
155
230
55
150
225
55
150
220
5.2
65
190
285
65
185
275
65
185
270
7
75
220
325
75
215
320
75
210
310
8.6
85
240
365
85
240
355
85
240
345
10
90
270
400
90
265
390
90
260
380
12
100
290
430
100
285
420
100
280
410
14
105
310
460
105
305
450
105
300
440
15.5
115
325
490
115
320
475
115
320
465
17
115
345
515
115
340
505
115
335
490
1) Number in each box is fl ow in liters per minute.
2) Actual fl ows may vary with brand and condition of hose.
3) Flows are approximate and do not account for losses in preconnect piping or changes in elevation.
4) 1BAR = 100 KPA