©Copyright Task Force Tips LLC 2006-2021
13
LIX-730 February 3, 2021 Rev09
7.4 OSCILLATION SPEED AND COVERAGE
Oscillation Speed: The chart shows how many times per minute the oscillator
makes one complete cycle as a function of flow. The higher the flow, the faster
it oscillates.
Nozzle Reach: Refer to the operation manual for the specific nozzle. For
reach with oscillation, subtract 20% from the distance.
Figure 7.4
8.0 STORAGE
The monitor may be stored pre-connected to its hose on the optional storage bracket, TFT part number XXL-B. The storage bracket may
be mounted on a horizontal surface, or a vertical surface with the nozzle end pointing down or sideways.
To mount the bracket, follow the instructions (LIX-735) provided with the bracket kit.
NOTICE
The type of nozzle and flow pressure are critical to the coverage area. The graph shows coverage
area based on the movement capability of the oscillating mechanism. Actual coverage will depend
on flow, pressure, type of nozzle, angle of fog pattern, and wind conditions.
WARNING
The Portable Monitor Storage Bracket is designed only to store the Portable Monitor. Attempting to
flow from the storage bracket can cause the monitor to become dislodged from the bracket and out
of control, causing severe injury or death. Always properly deploy the monitor before flowing.
APPROXIMATE
CYCLES/MIN
GPM
L/MIN
8
175
650
13
250
1000
21
375
1500
28
500
2000
BlitzForce OSCILLATION SPEED
Table 7.4
200
175
150
125
100
75
50
0
DIST
ANCE IN FEET
20 DEGREES
30 DEGREES
40 DEGREES
WIDTH OF COVERAGE
150 / 45m
125 / 38m
100 / 30m
75 / 23m
50 / 15m
COVERAGE AREA
OF BlitzForce OSCILLATING UNIT
61m
53m
45m
38m
30m
22m
15m
DIST
ANCE IN METERS