When the TASER CAM HD recorder is inserted into an X2 ECD and
disconnected from an external charging source (PC or wall power), it
provides power to the ECD and to the sensitive camera and microphone used
by the TASER CAM HD recorder.
The X2 ECD’s firmware must be upgraded to firmware version v03.022
or greater before installing the TASER CAM HD recorder. If the firmware
is outdated the recorder should provide power to the ECD, but the
recording function will not work.
Install the EVIDENCE Sync software on your computer, update the X2 and
TASER CAM HD
devices’ firmware, and configure your TASER CAM HD
recorder before attempting to use it with the ECD. See
Chapter 3: Charging
the TASER CAM HD Recorder
,
Chapter 5: Configuring the TASER CAM HD
Recorder with EVIDENCE Sync Software
, and
Chapter 8: Firmware Update
for more information.
Testing the TASER CAM HD Recorder
1.
Disconnect the TASER CAM HD recorder from the PC or wall power
and
remove the charging cable from the recorder.
2.
Confirm that the X2 safety is in the down (SAFE) position.
3.
Remove the
Smart™ cartridges from the X2 ECD. (See the
TASER X2
ECD User Manual
for more information on unloading Smart cartridges.)
4.
Confirm that the charging cable is removed from the TASER CAM HD
recorder.
5.
Firmly insert the TASER CAM HD recorder into the ECD until it clicks
and the
X2 ECD’s ejector button pops out completely.
When the
ECD’s safety is in the up (ARMED) position, the TASER
CAM HD unit starts recording. The light next to the TASER CAM HD
recorder’s lens will blink red to indicate the unit is recording. When
the
ECD’s safety is in the down (SAFE) position, the TASER CAM
HD recorder stops recording. (If the ECD is in the stealth mode or
the flashlight and LASERs are turned OFF [OO], the red LED will not