Tasco TA771ST Series Instruction Manual Download Page 6

 

Specification 

   

 

 

 

 

 

 

 

*Accuracy:±4% 

 

 

Operating instructions 

1.

 

Connect the flare nut onto the flare male connector in advance. 

Tighten the flare connection to the point where you can manually 

tighten by hand. 

 

 

 

 

 

 

2. Seize the grip firmly to exert torque. 

  The right torque value cannot be achieved without seizing the grip.   

 
3. Move the torque wrench in the direction of the arrow mark. 

  Strong torque in the opposite direction could cause damage to the torque 

wrench. 

 
 
 

Item No. 

Flare Nut 

(Refrigeration Size) 

Caliber(mm) 

× 

Tightening Torque 

N・m (kgf・cm) 

Length(mm) 

TA771ST-2 

1/4” 

17  ×  17.2 (175) 

220 

TA771ST-3 

3/8” 

22  ×  39.9 (407) 

230 

TA771ST-4 

1/2” 

26  ×  53.9 (550) 

285 

TA771ST-5 

5/8” 

29  ×  75.0 (765) 

295 

Flare nut 

Male flare connector 