Section 2.2 - Rear Panel
2-6
[45]
DIP switches (1 & 2)
The two DIP switches are both on when in the
down position. As shipped from the factory,
switch 1 is off (up) and switch 2 is on (dow), and
you probably will not need to change them.
However, when a passive device is connected to
the
EXT 1
connector and power is not provided
from the device to the tally supply pin, this switch
1 (
TALLY POWER
) should be set to the on
(down) position, allowing the RC-898 to use its
own power for this purpose.
Switch 2,
GND LIFT
(ground lift) controls the
isolation of the ground of the RC-848/DTRS sys-
tem from the ground of devices attached to the
EXT 1
and
EXT 2
ports. Usually this switch is in
the on (down) position, but you may need to turn it
off (up) if your system suffers from hum prob-
lems. However, a full discussion of ground loops
and their associated problems is outside the scope
of this manual, and we recommend that you con-
sult one of the many reference works on this sub-
ject if necessary.
[46]
Contrast
This control alters the contrast on the backlit LCD
display screen [11]. Use it to set the screen so that
it is easily visible from your preferred viewing
angle.
Summary of Contents for RC-898
Page 1: ...RC 898 Remote Control Unit D00376100A OWNER S MANUAL...
Page 8: ...Section 1 5 Accessories 1 4...
Page 9: ...2 RC 898 features 2 1 2 RC 898 features...
Page 18: ...Section 3 5 Memory and batteries 3 4...
Page 24: ...Section 4 5 Storing and recalling user setups 4 6...
Page 30: ...Section 5 2 Monitoring 5 6...
Page 46: ...Section 7 2 Unit related functions 7 8...
Page 56: ...Section 8 2 Advanced timecode functions 8 10...
Page 64: ...Section 9 4 Other DTRS control functions 9 8...
Page 74: ...Section 10 4 Dimensions 10 10...