background image

10

 

The canopy is not designed to carry snow loads. In the event there is snow on the 
canopy panels or the panels are covered in ice, please remove the snow and/ or 
ice layer immediately. 
 
In  order  to  maintain  the  water  drainage  system  unobstructed,  it  is  necessary 
to check  and  remove  waste  such  as  leaves,  conifer  needles,  and  other  type 
of waste from the gutters at least twice a year. This shall help maintain the flow 
capacity  of  the  gutters  mounted  in  the  supporting  legs  of  the  structure.  The 
manufacturer  recommends  that  structures  installed  in  the  vicinity  of  natural 
environment shall be cleaned as often as it may be required.

 

 
It is recommended to check the state of the structure - in springtime, before the 
start of the summer season, and in the fall - before the canopy is closed for the 
winter  season.  The  structure  may  be  checked  more  often  if  alarming  events 
occur.  Defects  resulting  from  failure  to  comply  with  the  above  shall  not  be 
covered by the manufacturer's warranty. 
 
Due to the design of the structure, the guide rails and the canopy profiles shall 
be checked  for  the  presence  of  ice  before  opening/  closing  the  canopy, 
particularly during cold temperatures. Icing may damage the components of the 
guides  themselves  as  well  as  the  electrical  components  and  this  shall  not 
be covered by the manufacturer's warranty. It is recommended to check the flow 
capacity of the guides each time before switching the canopy on (in case any 
foreign  matter,  such  as  leaves,  sticks,  insects  or  animals  got  inside) 

  ICING

.

 

 

Due to temperature differences, dew may appear on profiles and on the fabric, 
as well as condensation of water vapor under the canopy may occur 

 this shall 

not be deemed a product defect. 
 
Waste  causing  mechanical  damage  to  the  fabric  or  the  structure  shall 
be removed before the roof is folded. 

 

While the canopy is being folded, residual rainwater may pour out from the fabric 
panels. 

 

Shade differences between aluminum elements coming in in different batches 
of the product may occur. 

 

Taking into consideration the high level of pollution which leads to acid rain, and 
in case the structure is installed near roads, air channels, forests, trees with a risk 
of  resin  contamination,  and  additionally  it  is  not  cleaned  immediately  after 
contamination,  then  the  profiles  may  get  dirty,  making  it  impossible  to  clean 

Summary of Contents for Loft

Page 1: ...1 Tarasola Loft TARASOLA CANOPY AND COMPONENTS USE AND MAINTENANCE MANUAL...

Page 2: ...ICATION 3 3 TECHNICAL SPECIFICATION 3 3 1 Structure 3 3 2 Wind class 5 3 3 Electrical components for Tarasola Loft 5 3 4 Fabric components in the canopy 7 3 5 Technical limitations of the fabrics 8 4...

Page 3: ...49 km h which corresponds to 6 in the Beaufort scale The calculations concerning wind load resistance were performed according to the standard PN EN 1932 2013 09 EXTERNAL BLINDS AND SHUTTERS RESISTAN...

Page 4: ...tem The number of supporting legs depends on the width of the module The supporting pillars are equipped with brackets intended for screwing to the base 4 Side profile an aluminum crossbeam that integ...

Page 5: ...roducts we are offering a comprehensive product to our Clients the best on the market WARNING Due to the complexity and specificity of the product installation shall be performed by qualified personne...

Page 6: ...itch and vice versa The exception is having a switchboard Warning All wiring connection diagrams shall be obeyed otherwise warranty may be voided REMOTE CONTROLLER Manual radio control of one or more...

Page 7: ...MEDIATELY DISCONNECT THE MAIN POWER SUPPLY OF THE CANOPY AND REPORT THE FAILURE TO THE MANUFACTURER ONLY QUALIFIED PERSONNEL SHALL ENGAGE IN REPAIRING THE ELECTRICAL SYSTEM ANY ACTIONS CONSTITUTING SE...

Page 8: ...applied on acrylic and polyester materials creates a protective layer against dirt water and oily substances During rainfall water drops run down easily when the canopy is sloped Weather and mechanica...

Page 9: ...r s consent This increases the risk of product failure and shall result in the product warranty being voided Be careful when opening and closing the canopy Due to the risk of damaging one s hands it i...

Page 10: ...all be checked for the presence of ice before opening closing the canopy particularly during cold temperatures Icing may damage the components of the guides themselves as well as the electrical compon...

Page 11: ...g the canopy during conditions exceeding the indicated wind standard may result in damage or destruction of the canopy It is forbidden to place any items or objects on the material of the structure Th...

Page 12: ...12 5 CERTIFICATES...

Reviews: