0.   GENERAL

 

 

IOM manual Tapflo TE series

 

 

 

0.

 

GENERAL 

 

0.1.

 

Introduction  

 

The  Tapflo  Electro-Mechanic  Operated  Diaphragm  Pump  range  is  a  series  of  pumps  for 
industrial and hygienic applications. The pumps are designed to be safe, simple and easy to 
use and maintain. The pumps are suitable for almost all different chemicals used by the 
industry today. 

The pumps are powered with an electric motor which is coupled with the diaphragm shaft. 
To decrease the motor rotational speed a gearbox is used. This provides smooth and almost 
pulsation free operation. 

With  proper  attention  to  maintenance,  Tapflo  Pumps  will  give  efficient  and  trouble  free 
operation. This instruction manual will familiarise operators with detailed information about 
installing, operating and maintaining of the pump. 
When installing, operating and maintaining of the pump unit you must strictly follow the 
IOM manual. Otherwise injury or life hazard may occur. 
In  case  any  instructions  in  this  manual  are  unclear  or  any  information  is  missing,  please 
contact Tapflo before handling the pump.  

 

0.2.

 

Warning symbols  

 

The following warning symbols are present in this instruction manual. This is what they say: 
 

This symbol stands next to all safety instructions in this instruction manual where 
danger to life and limb may occur. Observe these instructions and proceed with 
utmost  caution  in  these  situations.  Inform  also  other  users  of  all  safety 
instructions. In addition to the instructions in this instruction manual, the general 
safety and accident prevention regulations must be observed.  
 
This signal stands at points in this instruction manual of particular importance 
for compliance with regulations and directives, for correct work flow and for the 
prevention  of  damage  to  and  destruction  of  the  complete  pump  or  its 
subassemblies. 

 
This symbol signals possible danger caused by the presence of electric fields or 
live wires. 

 

0.3.

 

Qualification and training of personnel 

 

The  personnel  in  charge  of  installation,  operation  and  maintenance  of  the  pumps  we 
produce must be qualified to carry out the operations described in this manual. Tapflo shall 
not be held responsible for the training level of personnel and for the fact that they are not 
fully aware of the contents of this manual. In case any instructions in this manual are unclear 
or any information is lacking, please contact Tapflo before handling the pump. 

 

 

Summary of Contents for TE Series

Page 1: ...m Pumps Original Instruction 2020 2 Read this instruction manual carefully before you install and operate the pump Pump models TE TXE50 TE TXE100 TE TXE200 TE TXE70 TE TXE120 TE TXE220 TE TXE80 TE TXE...

Page 2: ...5 Foundation 9 1 6 Environment 10 1 7 Suction and discharge piping 10 1 7 1 Rotary connections industrial pumps only 10 1 7 2 Connection of suction pipe 10 1 7 3 Connection of discharge pipe 10 1 8 H...

Page 3: ...6 Disposal after expiration of the expected lifetime 20 2 7 Waste of electrical and electronic equipment WEEE directive 20 2 8 Actions in emergency 21 3 MAINTENANCE 22 3 1 Inspections 22 3 2 When the...

Page 4: ...es 3 5 2 Capacity changes 32 5 3 Dry suction lift curve 33 5 4 Technical data 33 5 5 Dimensions 35 5 6 Tightening torques 36 5 7 Permitted loads on manifolds 37 6 WARRANTY 38 6 1 Warranty form 38 6 2...

Page 5: ...006 on machinery amending Directive 95 16 EC Directive 2014 30 EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to el...

Page 6: ...U Type Examination Certificate was carried out by J S Hamilton Poland Sp z o o Notified Body No 2057 and as a result a certificate No JSHP 20 ATEX 0025X was issued The object of the declaration descri...

Page 7: ...warning symbols are present in this instruction manual This is what they say This symbol stands next to all safety instructions in this instruction manual where danger to life and limb may occur Obser...

Page 8: ...phragm pumps IOM Manual Metal series diaphragm pumps IOM Manual Sanitary Series 0 5 Nameplate The nameplate is made in the below design It is made of AISI 304 stainless steel and placed on the pump ce...

Page 9: ...n The Suction Cycle Suction chamber 1 One diaphragm creates a suction action in one chamber right side when being pulled back from the housing Discharge chamber 2 The other diaphragm simultaneously tr...

Page 10: ...posed to any heat source e g radiator sun as this could result in a negative way on the tightness of the pump Do not remove the protective covers from the pump When in storage turn the shaft by hand a...

Page 11: ...sembly and installation of the pump If you wish to rotate the connections screw a threaded nipple into the connection and rotate it It is also advised to loosen the upper nuts to ease rotation NOTE Re...

Page 12: ...e TXE pumps are available for such applications that are equipped with an explosion proof gearmotor Metal pumps need only ATEX certified gearmotor to operate in hazardous environments Follow below ins...

Page 13: ...ey increase the wear of parts inside of the pump Centerblock temperature control In ATEX applications it is essential to monitor the centerblock temperature In case of failure the temperature can rise...

Page 14: ...llation should also be relieved of pressure Failure to do so may result in premature diaphragm failure 1 8 6 Noise level At tests the noise level from a Tapflo pump has not exceeded 80 dB A Under some...

Page 15: ...id Some parts of the TE pump can become hot during operation and cause burns therefore make sure to use appropriate protection when handling the pump 1 8 8 Rotating parts Do not tamper with the protec...

Page 16: ...s a pressure vacuum gauge on the suction piping a pressure gauge on the discharge piping The pressure intakes must be made of straight pieces of piping at a distance of minimum five diameters from the...

Page 17: ...e Y star or D Delta according to the power supply of the motor see figure below STAR DELTA Follow the connection standard used in the plant In no case connect the electrical motor directly to supply n...

Page 18: ...ear ratio Output RPM Voltage Frequency 0 75 kW 4 poles 8 22 172 230 400 50 Hz 4 poles 206 460 60 Hz 0 55 kW 4 poles 12 96 106 230 400 50 Hz 4 poles 127 460 60 Hz 0 25 kW 4 poles 24 8 56 230 400 50 Hz...

Page 19: ...pletely closed discharge these conditions can seriously damage the pump and cause injury to the operator If the pressure shown on the pressure gauge on the discharge piping does not increase turn off...

Page 20: ...quid containing particles the particulate matter contained in the liquid will be deposited and get stuck inside the pump chamber Therefore after finishing work the pump must be emptied of the remainin...

Page 21: ...pump at a minimum velocity of 1 5 m s in the normal flow direction from inlet to outlet It is recommended to run the pump slowly during CIP This is to obtain pressure balance on both sides of the diap...

Page 22: ...ons in emergency In case of a leakage of an unknown fluid respiratory protection should be worn and contact with the fluid avoided During firefighting no special hazards are to be expected from the pu...

Page 23: ...future as wear takes place You will be able to set schedules for maintenance of the pump and to select spare parts to be kept on stock 3 3 Routine inspection Frequent observation of the pump operation...

Page 24: ...pect the pump at least once a year Parts from KIT LIQ should be changed during inspection Tapflo recommend KIT VAL to be changed once per 2 years as well See paragraph 5 11 for detailed KIT content If...

Page 25: ...f the screws Replace O rings Check replace diaphragms Adjust installation eliminate stress when using a dampener provide separate support for it see dampener IOM manual Liquid comes out of the hole in...

Page 26: ...re that the pump has been fully emptied and washed When draining the liquid make sure that there is no danger for people or the environment For disassembly of the liquid side of the pump refer to the...

Page 27: ...g screws 411 Fig 3 6 5 Detach the centre block assembly 12 form the coupling Fig 3 6 6 Unscrew the centre block plug 33 Fig 3 6 7 By hand align the diaphragm shaft 16 in the middle of the centre secti...

Page 28: ...section Fig 3 6 11 Unscrew four coupling cover mounting screws 412 Fig 3 6 12 Remove the coupling cover 41 along with the motor side coupling 40 and the coupling insert 42 from the gear motor shaft F...

Page 29: ...ig 3 7 1 Rotate diaphragm shaft left and right to adjust groove with set screw Fig 3 7 2 Before assembly align coupling spider with gear motor shaft extension 3 7 1 Test run We recommend you to conduc...

Page 30: ...For liquid side spare parts see specific pump type IOM manual see chapter 0 4 Pos Q ty Description Material 12 1 Center block PA6 anodized aluminum 159 2 Diaphragm support plate AISI 316L 16 1 Diaphr...

Page 31: ...um 411 4 Coupling cover mounting screw c b side A4 70 412 2 Coupling cover mounting screw c b side A4 70 42 1 Coupling insert PUR 50 1 Bearing 4 3 Stocking recommendation Even at normal operation some...

Page 32: ...e 1 Y High lift valve seats plastic series only III Pump size 50 100 200 Plastic series 70 120 220 Metal series 80 125 225 Hygienic series IV Material of wetted metal parts P PE T PTFE S Stainless ste...

Page 33: ...ance curves are based on water at 20 C Other circumstances might change the performance See below how the capacity will change at different viscosities and suction lifts 5 2 Capacity changes Capacity...

Page 34: ...armotor kg lb 33 73 53 117 104 229 38 84 60 132 126 278 Connection standard 1 2 BSP female thread G 1 BSP female thread G 1 1 2 BSP female thread G 1 2 BSP female thread G 1 BSP female thread G 1 1 2...

Page 35: ...MS 3017 tri clamp DN 51 SMS 3017 tri clamp 60 Hz With stainless steel valve balls other materials may reduce suction Please consult us in this matter Flap valve version COMPONENT MATERIAL Pump housing...

Page 36: ...230 270 300 230 270 300 230 330 390 9 06 10 63 11 81 9 06 10 63 11 81 9 06 12 99 15 35 H 38 45 69 37 42 68 52 62 79 1 5 1 77 2 72 1 46 1 65 2 68 2 05 2 44 3 11 I 25 38 54 33 54 70 36 44 50 0 98 1 5 2...

Page 37: ...ion and safety the torque values should be checked frequently as part of preventive maintenance please contact Tapflo for interval proposals Although pump applications vary a general guideline is to r...

Page 38: ...utlet Nm X 43 7 4 Y 43 7 4 Z 43 7 4 TE70 Direction Load N inlet outlet Moment of force inlet outlet Nm X 31 6 3 Y 31 6 3 Z 31 6 3 TE120 Direction Load N inlet outlet Moment of force inlet outlet Nm X...

Page 39: ...pe Serial No see name plate or stamped on pump housing Description of the fault The installation Liquid Temperature C Viscosity cPs Spec grav kg m3 pH value Content of particles of max size mm Flow l...

Page 40: ...r documents specifically made available to Tapflo before entering into this agreement c high quality materials are used in the construction of the pumps and that machining and assembly are carried out...

Page 41: ...in accordance with standard CE normative and are tested where applicable by Tapflo Approval and tests by other control authority are for the customer s account The products shall not be considered de...

Page 42: ......

Reviews: