3. The heater will now be free to slide off the back plate (Fig. 3a). Gently slide the heater body away from the open end as shown in 
Fig. 3b to it from its mounting.

 

R e p l a c i n g   t h e   L a m p  

 

If  you are in any doubt about following the procedure below, please contact us for technical assistance. The mains power 
should  be  disconnected  before  any  attempts  are  made  to  replace  the  lamp.  The  following  should  be  carried  out  with       
compliance  to  I.E.E.  regulations.  Please  read  the  notes  above  with  regards  to  handling  and  buying  a  replacement  lamp     
before proceeding. 

 
1. Ensure the heater and lamp are cool and the power supply is disconnected by removing the plug from the socket outlet as shown in 
Fig. 1. 
 
2. Remove one of the heater end caps by removing the three screws with a pozi-head screwdriver as shown in Fig. 2.

 

Fig. 1 

Fig. 2 

Y o u r   R e p l a c e m e n t   L a m p  

 

It is important that your replacement lamp is exactly the same as the one it was supplied with. Failure to fit the exact 
same type could cause the heater to fail or even become dangerous. 
Please contact Tansun Limited or your service agent to purchase your replacement lamp and state the model number 
of the heater you wish to fit the lamp to. 
 

H a n d l i n g   t h e   R e p l a c e m e n t   L a m p  

 

Your new lamp should not be handled with bare hands. Remove finger marks with a soft cloth and methylated spirits 
or rubbing alcohol. Finger marks will burn into the lamps quartz glass causing premature failure.

 

M a i n t e n a n c e 

 

In the event of heater failure please contact the retailer or seller in the first instance. For spare parts or advice, please contact Tansun 
Limited. 

 

Disconnect  from  the  power  supply  by  removing  the  plug  from  the  mains  socket  before  commencing  any  maintenance  procedure 
including cleaning. 

 

To ensure optimum heat effectiveness, it is recommended that the reflector is kept clean. If dirt appears to build up on the reflector, 
the front safety guard should be removed and the reflector wiped with a lint-free cloth before re-fitting.

 

 

The  heater  is  supplied  with  a  safety  guard.  In  the  unlikely  event  that  this  gets  damaged,  please  contact  Tansun  Limited  for  an     
immediate replacement.

 

4. The back plate should now have the heater body removed from it (Fig. 4a) and can be placed on a safe, flat work surface (Fig. 4b) to 
proceed with the lamp change. 

Fig. 4a 

Fig. 7 

Fig. 6a 

Fig. 4b 

5. Remove the four screws (Fig. 5) from the terminal box and lift off the lid. 

Fig. 5 

7. From inside the heater body, gently pull the lamp wires through the sealing gasket so the lamp wires exit the terminal box and are 
free as shown below in Fig. 7. 

6. Remove the connector block retaining bridge by removing the screw and lifting out. This will allow the connector block to be lifted 
out of its locating lugs to allow for better access when connecting the new lamp terminals. For now though leave it in its locating lugs 
and unscrew the connector block screws as highlighted (Fig. 6a) and remove the white lamp wires so they are free (Fig. 6b). 

Fig. 6b 

RETAINING BRIDGE 

Summary of Contents for CARN4 1X1000H

Page 1: ...OR UK EUROPE CARN4 1X1000H CARN4 1X1300H HORIZONTAL MOUNTED MODELS CARN4 1X1000U CARN4 1X1300U ANGLED MOUNTED MODELS Spectrum House Unit 1 Ridgacre Road West Bromwich West Midlands B71 1BW England Tel 44 0 121 580 6200 Fax 44 0 121 580 6222 Email quartzinfo tansun com Website www tansun com ...

Page 2: ...lamp with bare hands If it is inadvertently touched remove finger marks with a lint free soft cloth and methylated spirit or alcohol Otherwise the finger marks will burn into the quartz glass of the lamp causing premature heater failure Do not use an extension lead with this product Keep the mains cable away from the body of the heater which will get hot during use Do not cover or obstruct the hea...

Page 3: ...can be mounted in a horizontal Fig A or angled Fig D manner depending on the model type see Table 1 for mounting orientation When mounting the heater horizontally do not position the heater at an angle more than 90 and less than 45 from the vertical mounting surface as shown in Fig A Ensure the terminal box is on the underside of the heater when mounting When angled mounting the heater ensure to l...

Page 4: ...er marks will burn into the lamps quartz glass causing premature failure M a i n t e n a n c e In the event of heater failure please contact the retailer or seller in the first instance For spare parts or advice please contact Tansun Limited Disconnect from the power supply by removing the plug from the mains socket before commencing any maintenance procedure including cleaning To ensure optimum h...

Reviews: