![TANSEL SL.450.H Manual Download Page 4](http://html.mh-extra.com/html/tansel/sl-450-h/sl-450-h_manual_818099004.webp)
STEP 1: SEPARATE SLIDE MEMBERS
STEP 2: INSTALL SPACER AND SLIDE MEMBER
STEP 3: RE-CONNECT THE SLIDE MEMBERS
TROUBLE SHOOTING
1) Slides feel tight when pulling in/out.
A) Check that you are using the correct screw type. If the screw head protrudes too much it will stop the slides operating smoothly.
Ensure you are using 8G and/or panhead screw.
B) Check that the slide members are correctly re-connected. Use the disconnect lever and re-connect again (follow step 4).
2) Slides are stuck behind the cabinet door.
You require a thicker spacer or batten but if it’s stuck by just a few millimetres we suggest using washers from the hardware store or use additional 4mm
spacers.
LHS
Turn the slides over & extend them fully until you can see the black disconnect lever. Pinch it in the direction of the arrow. This will release the slide members.
LHS
Ph (02) 9440 9800 or email us
CABINET
FRONT
EDGE
287
425
23
Set back from cabinet edge 5mm+
A)
Recommended set back from cabinet edge is 5mm+. The closer to the front edge of the cabinet the better, unless you have spice racks on
the door.
B)
Mark your holes on the cabinet wall with your desired set back.
C)
Drill holes and check that slide holes line up.
D)
Screw your slide member and nylon spacer to the cabinet wall using the appropriate length screw. NOTE: Ensure your screw is 8G or less,
otherwise they will prevent the slide working correctly.
A) Ensure the ball bearings are slid
forward before reconnecting.
B) Turn the outer slide member over
and connect to the inner member that
is installed to the cabinet wall.
C) Your slide and spacer combination should clear
your door obstuction.
Move slides in/out to ensure they are operating
smoothly.