background image

VXP Series Operation Manual  rev 1.0.2

2. Introduction

5

    

2. Introduction 

 

Designed and engineered in a unique partnership between Tannoy and Lab.gruppen,  the VXP Series 
comprises a range of powered (active) loudspeakers for demanding professional and commercial sound 
applications.  Each incorporates acclaimed Dual Concentric™ driver technology in tandem with on-board 
powering by Lab.gruppen’s IDEEA™ (IntelliDrive Energy Efficient Amplifier) module.

All VXP Series loudspeakers are designed to perform with very high efficiency and exceptionally low distortion, 
even when operating near peak output levels. At the heart of VXP Series is the latest genearation of Dual 
Concentric loudspeaker technology, which combines a high frequency driver and a low-mid driver on a 
common axis to create a true point source for all reproduced sounds. Dual Concentric eliminates the time 
alignment problems inherent with all separated driver enclosures, ensuring outstanding definition, detail and 
intelligibility at all points in the listening area.

Paired with Dual Concentric driver technology is the new IDEEA powering module from Tannoy’s sister 
company in Sweden, Lab.gruppen. At the heart of the IDEEA module is a patented Class D output stage 
capable of sustained high power levels with very low distortion – all with near 90% efficiency. A universal 
switching power supply accepts any mains voltage from 100 - 240 V (+/- 10%) at 50 Hz or 60 Hz through the 
appropriate IEC cord. The power control selector supports two operational modes: in Auto mode, the system 
turns on with signal present and turns off after 20 minutes of no signal input; manual mode allows the speaker 
to be turned on and off as required. Also provided is a switchable 90 Hz high-pass filter for use when adding 
a subwoofer. To ensure a long and trouble-free service life, IDEEA modules incorporate extensive features to 
safeguard internal circuits and the driver complement.

Within the VXP Series, system designers can choose from a variety of sizes, power levels and coverage 
patterns to suit particular requirements. For extended bass performance, models with the “.2” designation 
augment the Dual Concentric LF driver with a second matched LF driver.  The “HP” designation indicates 
extended power handling capabilities, while the “Q” suffix indicates incorporation on the new Q-Centric 
Waveguide (QCW™) for applications requiring an asymmetrical coverage pattern. The QCW horn can be 
rotated in a matter of minutes, allowing placement of the 75 x 40 degree pattern with either horizontal or 
vertical orientation.

All VXP models are enclosed in rugged birch plywood enclosures, with larger models equipped with double-
chamfered Integrip™ recessed handles for easy one- or two-handed carrying.  Reflecting Tannoy and Lab.
gruppen’s common reputation for reliability, all VXP Series loudspeakers are backed by a five-year warranty.

Summary of Contents for VXP SERIES

Page 1: ...VXPSERIES Operation Manual Professionalloudspeakers...

Page 2: ...uctions 8 Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or...

Page 3: ...Avis de conformite a la re glementation d Industrie Canada cet appareil nume rique de classe A est conforme a la norme ICES 003 InstallationInstructions 1 THIS PRODUCT MUST BE EARTHED Use only a flex...

Page 4: ...nel 7 5 Operation 8 5 1 AC power Requirements 9 5 2 Auto and Manual Power Modes 9 5 3 Cooling 9 5 4 LED Functions 9 5 5 Audio Connections 10 5 6 Gain Structure 10 5 7 Limiters 10 6 Equalisation 11 7 A...

Page 5: ...rsal switching power supply accepts any mains voltage from 100 240 V 10 at 50 Hz or 60 Hz through the appropriate IEC cord The power control selector supports two operational modes in Auto mode the sy...

Page 6: ...er and the shipping carrier immediately 3 1PreliminaryRecommendation VXP Series loudspeakers can produce high sustained output levels for long periods of time If users are in close proximity these lev...

Page 7: ...ed potentiometer for adjustment of speaker volume LED INDICATORS Top to bottom Limit protect indicates activity of built in speaker protection limiter Signal indicates when audio signal is present at...

Page 8: ...ER VXP SPEAKER RIGHT LINE LEVEL OUTPUT HIGH PASS OUTPUT RIGHT MONO LOWPASS OUTPUT POWER V SUBWOOFER HIGH PASS OUTPUT LEFT LEFT LINE LEVEL OUTPUT NOTE WHEN USING AN EXTERNAL DIGITAL CROSSOVER THE FULL...

Page 9: ...s than 2 seconds after a signal is present at the input MANUAL MODE The power mode may be switched to MANUAL to disable the APD and APO functions This allows use of an external power sequencer or manu...

Page 10: ...ink to the next speaker s XLR input socket 5 6GainStructure The VXP gain structure is designed to allow a low level source device to drive the loudspeaker to full output Maximum specified SPL will be...

Page 11: ...ld be applied gently and smoothly Because VXP loudspeakers are point source and phase coherent designs excessive equalization usually proves detrimental to the overall sound quality When one loudspeak...

Page 12: ...ts with the 30 degree angled rear panels together minimal dispersion pattern overlap is achieved guaranteeing an extraordinarily smooth transition In many applications the 90 or 75 degree dispersion p...

Page 13: ...VXP Series Operation Manual rev 1 0 2 8 Dimensions 13 8 Dimensions 388 0 15 28 280 0 11 02 275 0 10 83 180 0 7 09 135 0 5 31 60 60 333 0 13 11 225 0 8 86 215 0 8 46 75 75 115 0 4 53 VXP6 VXP8...

Page 14: ...ries Operation Manual rev 1 0 2 8 Dimensions 280 0 11 02 590 0 23 23 145 0 5 71 60 60 180 0 7 09 370 0 14 57 360 0 14 17 180 0 7 09 290 0 11 42 190 0 7 48 60 40 486 0 19 13 180 0 7 09 406 0 15 98 VXP8...

Page 15: ...0 2 8 Dimensions 15 370 0 14 57 360 0 14 17 180 0 7 09 290 0 11 42 190 0 7 48 60 40 486 0 19 13 180 0 7 09 406 0 15 98 370 0 14 57 360 0 14 17 180 0 7 09 290 0 11 42 190 0 7 48 60 40 486 0 19 13 180...

Page 16: ...71 370 0 14 57 190 0 7 48 40 0 1 57 155 0 6 10 180 0 7 09 40 0 1 57 290 0 11 42 180 0 7 09 190 0 7 48 60 40 258 0 10 16 155 0 6 10 590 0 23 23 43 0 1 69 180 0 7 09 504 0 19 84 180 0 7 09 364 0 14 33...

Page 17: ...VXP Series Operation Manual rev 1 0 2 8 Dimensions 17 9 Dimensions 590 0 23 23 43 0 1 69 180 0 7 09 504 0 19 84 180 0 7 09 364 0 14 33 450 0 17 72 200 0 7 87 420 0 16 54 200 0 7 87 VXP15Q...

Page 18: ...is guide is considered to be improper use Such use can be very dangerous overloading modifying damaging or assembling in a manner other than that clearly stated in the manual Tannoy Professional hardw...

Page 19: ...7900 1290 7900 1293 7900 1294 HF unit 7900 0683 Recone Kit 7900 0441 7900 0716 7900 0716 7900 0716 7900 0646 7900 0646 HF diaphragm 7900 1284 7900 1284 7900 1287 7900 1292 7900 1292 7900 1292 7900 12...

Page 20: ...ensions 333 x 225 x 215 mm HxWxD 13 1 x 8 9 x 8 1 HxWxD Net Weight 7 0 kg 15 4lbs Shipped Weight 15 5 kg 34 2 lbs Electronics Maximum signal input for clip Input attenuator at Maximum 4 5 dBu Hard cli...

Page 21: ...kg 47 4 lbs Electronics Maximum signal input for clip Input attenuator at Maximum 4 5 dBu Hard clip will occur at 14 5 dBu input signal Dynamic Range 106 dB Amplifier efficiency 90 Damping Factor 400...

Page 22: ...7 5 kg 38 6 lbs Shipped Weight 20 0 kg 44 1 lbs Electronics Maximum signal input for clip Input attenuator at Maximum 4 5 dBu Hard clip will occur at 14 5 dBu input signal Dynamic Range 106 dB Amplifi...

Page 23: ...t Weight 19 0 kg 41 9 lbs Shipped Weight 21 5 kg 47 4 lbs Electronics Maximum signal input for clip Input attenuator at Maximum 4 5 dBu Hard clip will occur at 14 5 dBu input signal Dynamic Range 106...

Page 24: ...ht 23 5 kg 51 8 lbs Shipped Weight 26 0 kg 57 3 lbs Electronics Maximum signal input for clip Input attenuator at Maximum 4 5 dBu Hard clip will occur at 14 5 dBu input signal Dynamic Range 106 dB Amp...

Page 25: ...Weight 23 0 kg 50 7 lbs Shipped Weight 25 0 kg 55 1 lbs Electronics Maximum signal input for clip Input attenuator at Maximum 4 5 dBu Hard clip will occur at 14 5 dBu input signal Dynamic Range 106 d...

Page 26: ...HxWxD Net Weight 35 0 kg 77 2 lbs Shipped Weight 38 0 kg 83 8 lbs Electronics Maximum signal input for clip Input attenuator at Maximum 4 5 dBu Hard clip will occur at 14 5 dBu input signal Dynamic Ra...

Page 27: ...cloth behind Connectors 1 x female XLR input 1 male XLR link 1 x Neutrik Powercon Controls Indicators Level Control Power LED Blue Signal LED Red Green Limit Protect LED Red Full Range HighPass Switch...

Page 28: ...Shipped Weight 31 5 kg 69 4 lbs Electronics Maximum signal input for clip Input attenuator at Maximum 4 5 dBu Hard clip will occur at 14 5 dBu input signal Dynamic Range 106 dB Amplifier efficiency 90...

Page 29: ...ase contact Customer Services Tannoy Ltd at the address given below or check at www tannoy com Customer Services Tannoy Ltd Rosehall Industrial Estate Coatbridge Strathclyde ML5 4TF Scotland Telephone...

Page 30: ...designed and constructed such that electromagnetic disturbances generated do not exceed levels allowing radio and telecommunications equipment and other apparatus to operate as intended and the appara...

Page 31: ...VXP Series Operation Manual rev 1 0 2 Notes 31 Notes...

Page 32: ...iddle East T 00 971 04 4401208 E enquiries tannoy com Tannoy adopts a policy of continuous improvement and product specification is subject to change Dual Concentric Integrip and Q Centric Waveguide a...