background image

8

VX Series

Quick Start Guide

9

Amplifi er Considerations

The VX series loudspeakers are optimized for use with the LAB GRUPPEN PLM+ series amplifi ers or LAKE LM series controllers used in combination with LAB GRUPPEN 
FP amplifi ers. A full range of DSP settings to suit any confi guration are provided for download on the TANNOY website. The use of third party amplifi cation and 
processing is only advised using the matrix of manual settings as well as the limiter calculator provided on the TANNOY website. VX series loudspeaker enclosures 
should be driven by high quality power amplifi ers designed for true professional use. Power amplifi ers should be capable of delivering long term broadband power 
equal to half the loudspeaker’s peak power rating at its stated nominal impedance. The use of underpowered amplifi ers must be avoided as heavily clipped signals can 
cause permanent loudspeaker damage. Limiters, crossovers and equalization points must be set in accordance with the settings provided on the TANNOY website. 
This will ensure the optimum sound quality and long-term reliability as well as protection from damage.

Neutrik speakON NL4 locking input connector(s) are provided, allowing options for input and link, passive, and bi-amp operation.

Recommended Amplifi er Power

Model

VX 5.2

VX 6

VX 8

VX 8.2

VX 8M 

VX 12

VX 12HP / VX 12Q

VX 12.2Q

VX 15HP / VX 15Q

Mode

Passive

Passive

Passive

Passive

Passive

Passive

Passive

Bi-amp LF Bi-amp HF

Passive

Bi-amp LF Bi-amp MHF

Passive

Bi-amp LF Bi-amp HF

Impedance

8 Ω

8 Ω

8 Ω

8 Ω

8 Ω

8 Ω

8 Ω

8 Ω

8 Ω

8 Ω

8 Ω

8 Ω

8 Ω

8 Ω

8 Ω

Minimum 
Amplifier 

Power

Continuous

RMS

130 W

100 W

130 W

200 W

130 W

200 W

350 W

350 W

80 W

500 W

350 W

350 W

400 W

400 W

80 W

Peak

520 W

400 W

520 W

800 W

520 W

800 W

1400 W

1400 W

800 W

2000 W

1400 W

1400 W

1600 W

1600 W

800 W

Connections

VX 5.2, VX 6, VX 8, VX 8.2

Model

Back Panel

Connector

Internal Schematic

Passive

Link Full Range -

1-

1+

2+

2-

Input Full Range +

Input Full Range -

speakON* NL4

Barrier Strip

1- 1+ 1-

1+

+

+ + +

Input Full Range -

Input Full Range +

Link Full Range +

1 +
1 -

2 +
2 -

NL4
Input / 
Link

NL4
Input /
Link

HF

HPF

LF

LPF

1 +
1 -

2 +
2 -

1 +
1 -
1 +
1 -

Barrier
Strip
Input /
Link

VX 8M

Model

Back Panel

Connector

Internal Schematic

Passive

1-

1+

2+

2-

Input Full Range +

Input Full Range -

speakON* NL4

1 +
1 -

2 +
2 -

NL4
Input / 
Link

NL4
Input /
Link

HF

HPF

LF

LPF

1 +
1 -

2 +
2 -

VX 12

Model

Back Panel

Connector

Internal Schematic

Passive

Link Full Range -

1-

1+

2+

2-

Input Full Range +

Input Full Range -

speakON* NL4

Barrier Strip

1- 1+ 1-

1+

+ +

+ +

Input Full Range -

Input Full Range +

Link Full Range +

1 +
1 -

2 +
2 -

NL4
Input / 
Link

NL4
Input /
Link

HF

HPF

LF

LPF

1 +
1 -

2 +
2 -

1 +
1 -
1 +
1 -

Barrier
Strip
Input /
Link

VX 12HP, VX 12Q, VX 12.2Q, VX 15HP, VX 15Q

Model

Back Panel

Connector

Internal Schematic

Passive

speakON* NL4

Barrier Strip

1-

1+

2+

2-

Input Full Range +

Input Full Range -

1- 2+ 2-

1+

+

+ + +

Input Full Range -

Input Full Range +

1 +
1 -

2 +
2 -

NL4
Input / 
Link

NL4
Input /
Link

HF

HPF

LF

LPF

1 +
1 -

2 +
2 -

1 +
1 -

2 +
2 -

Barrier
Strip
Input /
Link

Bi-amp

1-

1+

2+

2-

1- 2+ 2-

1+

+ + + +

 Input LOW 1 +

Input LOW 1 -

Input LOW 1 +

speakON* NL4

Barrier Strip

 Input LOW 1 -

Input HIGH 2 +

Input HIGH 2 -

 Input HIGH 2 -

 Input HIGH 2 -

 Amplifier Channel 1

 Amplifier Channel 2

1 +

1 -

2 +

2 -

NL4

Input / 

Link

NL4

Input /

Link

HF

LF

1 +

1 -

2 +

2 -

1 +

1 -

2 +

2 -

Barrier

Strip

Input /

Link

Summary of Contents for VX 12

Page 1: ...ower Dual Full Range Loudspeaker with Q Centric Waveguide Low Frequency Driver for Portable and Installation Applications VX 12 WH VX 8M VX 8 2 WH VX 8 WH VX 6 WH VX 5 2 WH 12 8 6 5 Dual Concentric Fu...

Page 2: ...Sde6 3mmodebayonetaprefijados Cualquierotra instalaci nomodificaci ndebeserrealizada nicamente porunt cnicocualificado Estes mbolo siemprequeaparece leadviertedelapresenciadevoltaje peligrososinaislar...

Page 3: ...t des marques ou marques d pos es de MUSICTribe Global Brands Ltd MUSICTribe Global Brands Ltd 2018Tous droits r serv s Pourconna trelestermesetconditionsdegarantie applicables ainsiquelesinformations...

Page 4: ...terumeventualimpactonegativo noambienteenasa dehumanadevidoasubst ncias potencialmenteperigosasqueest ogeralmente associadasaosEEE Aomesmotempo asuacolabora o paraaelimina ocorrectadesteprodutoir cont...

Page 5: ...assive Bi amp LF Bi amp HF Impedance 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Minimum Amplifier Power Continuous RMS 130 W 100 W 130 W 200 W 130 W 200 W 350 W 350 W 80 W 500 W 350 W 350 W 400 W 400 W 80 W Peak 5...

Page 6: ...personal injury resulting from improper use installation or operation of the product Regular checks must be conducted by qualified personnel to ensure that the system remains in a secure and stable co...

Page 7: ...90 conical 6dB point 75 conical 6dB point 75 H x 40 V 6dB points Directivity factor Q 8 1 9 6 10 1 13 Directivity index DI 9 2 9 8 10 11 1 Power handling IEC Passive Bi amp 200 W continuous 800 W peak...

Page 8: ...esellernotbelocatedinyourvicinity youmaycontactthe MUSIC TribeAuthorizedFulfillerfor yourcountrylistedunder Support attannoy com Should yourcountrynotbelisted pleasecheckifyourproblem canbedealtwithby...

Page 9: ......