Introduction

The VQ full range products utilize a unique driver technology to radiate a coherent single point source for superior dispersion control when coupled to our single horn. 

This advanced design aligns the acoustical centres of the transducers providing a single coherent wavefront emanating from the throat.
The driver uses two concentric annular ring diaphragms. The larger of the two has a 3.5” voice coil and reproduces frequencies from 400 Hz to 7 kHz. Another major 

advantage here is that there is no crossover anywhere near the vocal region ensuring the most natural and phase coherent reproduction at this critical area. The 2” HF 

diaphragm takes over at 7 kHz to 22 kHz by way of a passive or an active crossover. The external casting features extensive heatsinking ensuring good heat transfer for 

high power handling and very low power compression.

Connectors/Cabling

Input Connector Panels

Note : The VQ 60 and VQ 100 are configured as standard for Bi-Amp operation.
Tri-Amp operation is possible using the Barrier strip input terminals.
The VQ DF is configured as standard for single amp operation. Bi-Amp operation is possible using the Barrier strip input terminals. 
The VQ MB is configured for single amp operation.

VQ 60 / 100

VQ DF

VQ MB

The VQ 60, VQ 100 and VQ DF are fitted with 4-pole Neutrik Speakon´ connectors and barrier strip for fixed installations. 

Speakon Connections -

Speakon has the following advantages over EP and XLR type connectors: 
All terminations are solderless; this makes life easier at the time of installation or when field servicing is required. Contacts will accept 6 sq. mm wire with an outside 

diameter of up to 15 mm and a current rating of 30 Amps. The pins of the 2 Speakon sockets identified input/output on the rear of the input panel are paralleled within 

the enclosure to facilitate the connection to additional VQ loudspeakers (except the VQ MB). Tannoy has adopted the standard professional audio wiring convention for 

the VQ product.

Barrier Strip Connections
The barrier strip accommodates bare wire, tinned leads or spade connectors.  The barrier strips are specifically designed for utilization in fixed/permanent installations.  

The VQ 60 and VQ 100 are configured for Bi-amp operation; by removing the 4 link wires between the two barrier strips on the termination panel tri-amp operation is 

possible. The VQ DF is configured for single amp operation; by removing the 4 link wires between the two barrier strips on the termination panel bi-amp operation is 

possible.
VQ 60/100 Bi-amp –   Connect LF amplifier to LF +/- on top row of barrier strip. 

 

 

Connect MF/HF amplifier to MF/HF +/- on bottom row of barrier strip.

VQ 60/100 Tri-amp -   Connect LF amplifier to LF +/- on top row of barrier strip. 

 

 

Connect MF amplifier to MF +/- on top row of barrier strip. 

 

 

Connect HF amplifier to HF +/- on top row of barrier strip.

VQ DF Single Amp -   Connect MF/HF amplifier to MF/HF +/- on bottom row of barrier strip.
VQ DF Bi-amp -  

Connect MF amplifier to MF +/- on top row of barrier strip. 

 

 

Connect HF amplifier to HF +/- on top row of barrier strip.

VQ MB -   

 Connect amplifier to LF +/- terminals.

Note that looping out to additional loudspeakers will have the effect of reducing the load on the amplifier. Avoid loading amplifiers too low. If the amplifier is rated for 

4 ohms minimum, don't give it a 2 ohm load. Even when the amplifier is rated down to 2 ohms remember that in order to keep up with the power the circuit will have 

much higher current than before and the wiring will have to handle it. Not only will the wiring losses grow but the damping factor of the system will be degraded. It 

might be better to run separate cables from the amp to the speakers or divide the load across two amplifier channels.
Cable choice consists mainly of selecting the correct cross sectional area in relation to the cable length and the load impedance. A small cross sectional area would 

increase the cables series resistance, inducing power loss, and response variations (damping factor). 
Connectors should be wired with a minimum of 2.5 sq. mm (12 gauge) cable. This will be perfectly satisfactory under normal conditions. In the case of very long cable 

runs the wire size should exceed this. The following table shows the change in resistance, sensitivity loss and damping factor due to the effects of cable diameter and 

length for two nominal impedance loads (4 ohms & 8 ohms). Use this table to determine a suitable cable diameter for the length of run you require.  For resultant 

damping factor, values greater than 20 are generally considered adequate for high quality sound reinforcement systems.

VQ 60 and VQ 100

 

Speakon Connections

LF Negative (-ve)
LF Positive (+ve)

MF/HF Positive (+ve)

 

MF/HF Negative (-ve)

VQ DF Speakon
Connections

No connections on pins
1+ and 1-

MF/HF Negative (-ve)

MF/HF Positive (+ve)

VQ MB Speakon
Connections

LF Negative (-ve)
LF Positive (+ve)

No connections on pins
2+ and 2-

Summary of Contents for VQ Series

Page 1: ...F VQ 64DF 2 Way Down Firing Dual Concentric Mid High Loudspeaker for High Performance Installation Applications VQ 64MH 2 Way Dual Concentric Mid High Large Format Loudspeaker for High Performance Ins...

Page 2: ...os Midas KlarkTeknik Lab Gruppen Lake Tannoy Turbosound TC Electronic TC Helicon Behringer Bugera Auratone y Coolaudio son marcas comerciales o marcas registradas de MusicTribe Global Brands Ltd Music...

Page 3: ...lectrocution Utilisezuniquementdesc blesd enceintesprofessionnels dehautequalit avecfichesJackmono6 35mmoufiches verrouillagesd j install es Touteautreinstallationou modificationdoit treeffectu euniq...

Page 4: ...cabili e le informazioni aggiuntive relative alla garanzia limitata di MusicTribe consultare online i dettagli completi su musictribe com warranty Informazioni importanti DISCLAIMER LEGALE GARANZIA LI...

Page 5: ...tion panel tri amp operation is possible The VQ DF is configured for single amp operation by removing the 4 link wires between the two barrier strips on the termination panel bi amp operation is possi...

Page 6: ...offer quick simple and secure solutions for mounting specific VQ loudspeakers This hardware has been designed and manufactured with a high safety load factor for its specific role To ensure the safest...

Page 7: ...s which also double as the flying points and accept VEB M10 eyebolts To install the VEB M10 eyebolts remove the original M10 counter sunk screws from the locations you wish to install the VEB M10 eyeb...

Page 8: ...with the required experience and certification to perform the necessary tasks Fixing of hanging points in a roof should always be carried out by a professional rigger and in accordance with the local...

Page 9: ...bolts and replace with either the M10 screw or the supplied eyebolts Locate the four M10 eyebolts from the fixings kit supplied and insert these through the array plate into the rigging points in the...

Page 10: ...arrying handles 12 x M10 flying inserts 2 x recessed carrying handles 12 x M10 flying inserts Dimensions 925 x 694 x 515 mm 36 4 x 27 3 x 20 3 925 x 694 x 515 mm 36 4 x 27 3 x 20 3 500 x 694 x 515 mm...

Page 11: ...t information Aspectos importantes Informations importantes Weitere wichtige Informationen Outras Informa es Importantes Informazioni importanti 1 Register online Pleaseregisteryournew MusicTribeequip...

Page 12: ...not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encour...

Page 13: ......

Reviews: