The Ceiling Speaker System shall consist of a 150mm (6.00") mineral loaded mid bass driver with coaxially mounted 19mm (0.75") high frequency unit and

passive frequency dividing network mounted in a vented, injection moulded, paintable front baffle in UL94V-0 ABS material.

The backcan shall be constructed of zinc plated steel. A recessed termination box shall be integrated with the backcan, a removable locking connector with

screw terminals for secure wire termination with "loop through" facility shall be provided. Strain relief will be provided by a clamping mechanism for use with

plenum rated cable or conduit. A safety ring is located on the rear of the backcan for a load bearing safety bond.

Performance of the ceiling speaker shall meet or exceed the following criteria: The system shall have a conical coverage pattern of 93 degrees (1kHz to

6kHz). Frequency response measured on axis shall be 60Hz -24kHz (-10dB from rated sensitivity, measured in an IEC baffle in an anechoic chamber) with

no equalization. Sensitivity shall be 91dB (1W @ 1m). Long term power handling capacity as defined in EIA-426B test shall be 60W, recommended amplifier

power 120W. The nominal system impedance shall be 6W (in low impedance setting).

The ceiling speaker system shall be equipped with a 60W high performance line transformer for use in 70.7 or 100 Volt distributed audio systems with 60, 30,

15, 7.5* Watt taps available. An easily accessible rotary switch located on the front baffle shall be available for selecting transformer and low impedance set-

tings. A weather resistant perforated steel grille covers the transducer and switch.

Two support rails and one C-Ring shall be included with the ceiling monitor system. The front face diameter shall not exceed 279.5mm (11.01"), overall depth

from the front of the ceiling to the top of the safety loop shall not exceed 258.5mm (10.18").The template cut out diameter shall be 250mm (9.84")

The Ceiling Monitor System shall be the.....CVS6

*70 Volt only

Architectural specifications

Summary of Contents for CVS6

Page 1: ...6 is supplied with an integral zinc plated steel back can with recessed termination box to satisfy the vast majority of installation application requirements The removable locking connector has screw terminals for secure wire termination and loop through facil ity Strain relief is provided by a clamping mechanism for use with plenum rated cable or conduit Security toggle clamps make for quick and ...

Page 2: ...noy com Tannoy operates a policy of continuous research and development The introduction of new materials or manufacturing methods will always equal or exceed the published specifications which Tannoy reserves the right to alter without prior notice Please verify the latest specifications when dealing with critical applications Low Frequency 150mm 6 00 mineral loaded cone High Frequency 19mm 0 75 ...

Page 3: ...m CVS 6 CVS6 data file issue 1 06 15 01 08 PERFORMANCE MEASUREMENTS 50 60 70 80 90 100 10 100 1000 10000 100000 0 5 10 15 20 25 30 35 1 10 100 1000 10000 100000 p 50 60 70 80 90 100 10 100 1000 10000 100000 0 deg 10 deg 20deg 30deg 40deg ANECHOIC FREQUENCY RESPONSE IMPEDANCE OFF AXIS RESPONSE 1m on axis frequency response frequency Hz SPL 1W 1m dB frequency Hz Impedance vs frequency frequency Hz I...

Page 4: ...6 7473 E enquiries tannoy com E inquiries tannoyna com E anfragen tannoy com E ventes tannoy com CVS 6 CVS6 data file issue 1 06 15 01 08 PERFORMANCE MEASUREMENTS 0 30 60 90 120 150 180 210 240 270 300 330 360 100 1000 10000 g 1 10 100 100 1000 10000 Q BEAMWIDTH DIRECTIVITY INDEX Beamwidth vs Frequency frequency Hz frequency Hz DI vs Frequency Q Degrees ...

Page 5: ...ORMANCE MEASUREMENTS POLAR PLOTS 1 3 OCTAVE 48 36 24 12 0 0 30 60 90 270 300 330 100 Hz 125 Hz 160 Hz 200 Hz 48 36 24 12 0 0 30 60 90 270 300 330 250 Hz 315 Hz 400 Hz 500 Hz 48 36 24 12 0 0 30 60 90 270 300 330 48 36 24 12 0 0 30 60 90 270 300 330 48 36 24 12 0 0 30 60 90 270 300 330 48 36 24 12 0 0 30 60 90 270 300 330 630 Hz 800 Hz 1 kHz 1 25 kHz 1 6 kHz 2 kHz 2 5 kHz 3 15 kHz 4 kHz 5 kHz 6 3 kH...

Page 6: ...00 0 63 4 50 0 18 SUPPLIED ACCESSORIES C RING 244 6 9 63 246 5 9 70 15 9 0 63 258 5 10 18 279 5 11 01 OPTIONAL ACCESSORIES PLASTER MUD RING 60 00 2 36 180 00 7 09 205 00 8 07 230 00 9 06 255 00 10 04 280 00 11 02 305 00 12 01 650 00 25 59 10 00 0 39 251 00 9 88 318 00 12 52 168 00 5 96 251 00 7 40 318 00 11 34 80 00 3 15 168 50 5 96 8001 4240 CVS6 White paintable 2 15 00 33 07 8001 4180 CVS6 Plast...

Page 7: ...d the following criteria The system shall have a conical coverage pattern of 93 degrees 1kHz to 6kHz Frequency response measured on axis shall be 60Hz 24kHz 10dB from rated sensitivity measured in an IEC baffle in an anechoic chamber with no equalization Sensitivity shall be 91dB 1W 1m Long term power handling capacity as defined in EIA 426B test shall be 60W recommended amplifier power 120W The n...

Page 8: ...y Deutschland Tannoy France T 00 44 0 1236 420199 T 00 1 519 745 1158 T 00 49 180 1111 881 T 00 33 0 1 7036 7473 E enquiries tannoy com E inquiries tannoyna com E anfragen tannoy com E ventes tannoy com CVS 6 CVS6 data file issue 1 06 15 01 08 NOTES ...

Reviews: