Tannoy CVS Series Quick Start Manual Download Page 8

14

CVS Series

Quick Start Guide

15

6.3. Installation Instructions for Optional Plaster Ring

An

 

optiona

p

l

aster

 

(mud)

 

ring

 

bracket

 

is

 

avai

l

ab

l

e

 

from

 T

ANNOY.

 T

his

 

bracket

 

is

 

designed

 

to

 

be

 

pre-insta

ll

ed

 

into

 

new

l

y

 

constructed,

 

non-suspended

 

cei

l

ings.

1.

 

Nai

or

 

screw

 

the

 

p

l

aster

 

ring

 

to

 

the

 

joists.

 

(

F

ig.1)

2.

 

Lay

 

the

 

speaker

 

wiring

 

to

 

where

 

the

 

speaker

 

wi

ll 

be

 

fi

 

tted

 

and

 

comp

l

ete

 

the

 

p

l

astering

 

work

 

on

 

the

 

cei

l

ing.

3.

 

Cut

 

out

 

the

 

ho

l

e

 

in

 

the

 

cei

l

ing

 

using

 

a

 

pad

 

saw.

 

(

F

ig.2)

4

.

 

Go

 

to

 

section

 7 

for

 

instructions

 

on

 

wiring

 

then

 

return

 

to

 

point

 

5

 

be

l

ow.

5.

 

S

l

ide

 

the

 

speaker

 

assemb

l

y

 

through

 

the

 

ho

l

e

 

and

 

turn

 

the

 

screws

 

to

 

extend

 

the

 

mounting

 

wings.

T

ighten

 

the

 

screws

 

unti

a

 

fi

 

rm

 

grip

 

is

 

achieved.

 

I

f

 

using

 

a

 

power

 

driver,

 T

ANNOY

 

recommends

 

a

 

torque

 

setting

 

of

 

1.5

 

Nm.

 

(

F

ig.3)

 

DO NOT OVERTIGHTEN!

6.

 

Connect

 

a

 

secondary

 

support

 l

ine

 

to

 

safety

 

tab.

 

Some

 

construction

 

codes

 

require

 

use

 

of

 

this

 

secondary

 

support

 

point,

 

which

 

shou

l

d

 

connect

 

to

 

a

 

separate

 

secure

 

support

 

point

 

using

 

a

 

suitab

l

e

 

support

 l

ine.

 

Consu

l

t

 

construction

 

codes

 

in

 

your

 

region.

7

.

  I

nsert

 

gri

ll

e

 

by

 

pushing

 

it

 

onto

 

the

 

speaker.

 

(

F

ig.

4

)

7. Wiring and Setting Up

1.

 

Remove

 

the

 

wiring

 

cover

 

at

 

the

 

back

 

of

 

the

 

speaker

 

can

 

to

 

access

 

the

 E

uro-type

 

connector

 

p

l

ug

 

and

 

socket.

 

F

eed

 

the

 

cab

l

e

 

through

 

the

 

g

l

and

 

and

 

attach

 

the

 E

uro-type

 

connector.

 

(

F

ig.1)

2.

  F

or

 

connection

 

to

 

an

 

amp

l

ifi

 

er,

 

use

 

Pins

 

1

 

and

 

2

 

(

F

ig.2):

• • 

Pin

 

1

 

is

 

positive

• • 

Pin

 

2

 

is

 

negative

 

F

or

 

connection

 

to

 

additiona

speakers

 

in

 

a

 

distributed

 l

ine,

 

pins

 

3

 

and

 4 

are

 

in

 

para

ll

e

where:

• • 

Pin

 

3

 

is

 

negative

• • 

Pin

 4 

is

 

positive

3.

  T

ighten

 

the

 

cab

l

e

 

g

l

and

 

and

 

p

l

ug

 

in

 

the

 E

uro-type

 

connector.

 

Rep

l

ace

 

the

 

cover

 

and

 

fi

 

x

 

using

 

the

 

supp

l

ied

 

screws.

 

 

THE SPEAKER IS SUPPLIED IN LOW IMPEDANCE MODE. NEVER CONNECT THE SPEAKER TO 
A 70/100 VOLT AMPLIFIER WHILE IT IS SET FOR LOW IMPEDANCE.

4

.

  T

he

 

CVS

 4 

Micro

 

(

E

N5

4

)

 

is

 

fi

 

tted

 

with

 

a

 

15

 

W

 

transformer.

 

When

 

used

 

in

 

distributed-

l

ine

 

systems,

 

the

 

transformer

 

can

 

be

 

tapped

 

at

 

15

 

W,

 7

.5

 

W

 

and

 

3.

7

5

 

W,

 

with

 

an

 

additiona

1.9

 

W

 

tapping

 

for

 7

0.

V

 l

ine

 

systems.

 

(

F

ig.3)

5.

  T

he

 

CVS

 4 

(

E

N5

4

)

 

is

 

fi

 

tted

 

with

 

a

 

30

 

W

 

transformer.

 

When

 

used

 

in

 

distributed-

l

ine

 

systems,

 

the

 

transformer

 

can

 

be

 

tapped

 

at

 

30

 

W,

 

15

 

W

 

and

 7

.5

 

W,

 

with

 

an

 

additiona

3.

7

5

 

W

 

tapping

 

for

 7

0.

V

 l

ine

 

systems.

 

(

F

ig.

4

)

6.

  T

he

 

CVS

 

6

 

(

E

N5

4

)

 

is

 

fi

 

tted

 

with

 

a

 

60

 

W

 

transformer.

 

When

 

used

 

in

 

distributed-

l

ine

 

systems,

 

the

 

transformer

 

can

 

be

 

tapped

 

at

 

60

 

W,

 

30

 

W,

 

and

 

15

 

W,

 

with

 

an

 

additiona

l 7

.5

 

W

 

tapping

 

for

 7

0.

V

 l

inesystems.

F

ig.1

F

ig.2

F

ig.

4

F

ig.3

F

ig.1

F

ig.2

F

ig.3

F

ig.

4

Summary of Contents for CVS Series

Page 1: ... for Installation Applications EN 54 Certified CVS 4 EN 54 4 Coaxial In Ceiling Loudspeaker for Installation Applications EN 54 Certified CVS 4 MICRO EN 54 4 Coaxial In Ceiling Loudspeaker with Shallow Back Can for Installation Applications EN 54 Certified ...

Page 2: ...Sde6 3mmodebayonetaprefijados Cualquierotra instalaciónomodificacióndebeserrealizadaúnicamente poruntécnicocualificado Estesímbolo siemprequeaparece leadviertedelapresenciadevoltaje peligrososinaislardentrodelacaja estevoltajepuedesersuficienteparaconstituirunriesgo dedescarga Estesímbolo siemprequeaparece leadviertesobreinstruccionesoperativas ydemantenimientoqueaparecenenla documentaciónadjunta ...

Page 3: ...LICON BEHRINGER BUGERA et DDA sont des marques ou marques déposées de MUSIC Group IP Ltd MUSIC Group IP Ltd 2017Tous droits réservés Pourconnaîtrelestermesetconditionsdegarantie applicables ainsiquelesinformationssupplémentaires etdétailléessurlaGarantieLimitéedeMUSICGroup consultezlesiteInternetmusic group com warranty Vorsicht DiemitdemSymbolmarkierten AnschlüsseführensovielSpannung dassdieGefah...

Page 4: ...rlevadoparaumcentroderecolhalicenciadoparaa reciclagemderesíduosdeequipamentoseléctricose electrónicos EEE Otratamentoincorrectodestetipo deresíduospodeterumeventualimpactonegativo noambienteenasaúdehumanadevidoasubstâncias potencialmenteperigosasqueestãogeralmente associadasaosEEE Aomesmotempo asuacolaboração paraaeliminaçãocorrectadesteprodutoirácontribuir paraautilizaçãoeficientedosrecursosnatu...

Page 5: ...s ie BS 5839 1998 it is required that in the event of fire that failure of the circuit to which the loudspeaker is connected does not occur before evacuation of the building is complete Suitable measures include a use of terminal blocks for connection to primary with a melting point of not less than 650 C for example constructed from ceramic materials b use of terminal blocks of a lower melting po...

Page 6: ...ws for Mounting Wings Rotary Switch Tuning Ports Cable Safety Tab Tuning Ports Mounting Wings Safety Tab Mounting Wings Cable Clamp 5 Accessories Standard Accessories Optional Accessories C Ring Tile bridge kit Note A tile bridge kit must always be used when installing into suspended ceiling tiles Paint Mask Cut out template Plaster Mud Ring ...

Page 7: ...odes require use of this secondary support point which should connect to a separate secure support point using a suitable support line Consult construction codes in your region Go to section 7 for instructions on wiring and set up instructions 6 2 Installation Guide for SheetRock Ceilings 1 Mark the cut out area on the ceiling by tracing around the template provided Fig 1 2 Cut out the hole in the...

Page 8: ...e the wiring cover at the back of the speaker can to access the Euro type connector plug and socket Feed the cable through the gland and attach the Euro type connector Fig 1 2 For connection to an amplifier use Pins 1 and 2 Fig 2 Pin 1 is positive Pin 2 is negative For connection to additional speakers in a distributed line pins 3 and 4 are in parallel where Pin 3 is negative Pin 4 is positive 3 T...

Page 9: ...CVS 6 EN54 Dimensions CVS 6 EN54 Template Cut Out Size 250 mm 191 2 7 53 Ø213 0 8 39 Ø174 8 6 88 224 9 8 85 14 7 0 58 8 2 CVS 4 EN54 Dimensions CVS 4 EN54 Template Cut out Size 180 mm 236 0 9 30 262 0 10 35 15 9 0 63 Ø279 6 11 01 Ø244 6 9 63 ...

Page 10: ... horizontal 125 vertical 157 horizontal 157 vertical 155 horizontal 155 vertical 4 kHz 70 horizontal 66 vertical 85 horizontal 85 vertical 86 horizontal 88 vertical Transducers Low Frequency 150 mm 6 mineral loaded cone material 100 mm 4 mineral loaded cone material 100 mm 4 mineral loaded cone material High frequency 19 mm 0 75 coaxially mounted 19 mm 0 75 coaxially mounted 19 mm 0 75 coaxially m...

Page 11: ...o readtheterms andconditionsofourwarranty ifapplicable 2 Malfunction Shouldyour MUSIC Group AuthorisedResellernotbelocatedinyourvicinity youmaycontactthe MUSIC GroupAuthorisedFulfillerfor yourcountrylistedunder Support attannoypro com Shouldyourcountrynotbelisted pleasecheckifyour problemcanbedealtwithbyour OnlineSupport which mayalsobefoundunder Support attannoypro com Alternatively pleasesubmita...

Page 12: ......

Reviews: