background image

2

CONTENTS

3

INTRODUCTION

1

UNPACKING

2

SAFETY NOTICES

3

ACCESSORIES

5

INSTALLATION GUIDE

6

MECHANICAL INSTALLATION GUIDE FOR SUSPENDED CEILINGS

MECHANICAL INSTALLATION GUIDE FOR SHEET-ROCK CEILINGS

MECHANICAL INSTALLATION INSTRUCTIONS FOR OPTIONAL PLASTER RING

INSTRUCTIONS FOR OPTIONAL PRE-INSTALLATION BACK-CAN (PI MODELS ONLY)

WIRING AND SETTING UP

DIMENSIONS

CMS 501 DIMENSIONS

CMS 601 DIMENSIONS

TECHNICAL SPECIFICATIONS

WARRANTY

DECLARATION OF CONFORMITY

6.1

6.2

6.3

6.4

7

8

8.1

8.2

9

11

12

SAFETY NOTE:

In order to comply with relevant fire safety regulations (i.e. BS 5839:1998), it is required that in the event of fire,
that failure of the circuit to which the loudspeaker is connected does not occur before evacuation of the building is
complete. Suitable measures include: -
 a) use of terminal blocks (for connection to primary) with a melting point of not less than 650°C, for example
constructed from ceramic materials;
 b) use of terminal blocks of a lower melting point but protected with thermal insulation;

) use of terminal blocks such that, on melting, an open-circuit or a short-circuit does not occur.

1. INTRODUCTION

Thank you for purchasing this Tannoy Ceiling Monitor System product.  This product range is suited
for high-level music and speech reinforcement applications requiring exceptional sonic quality with
uncompromised reliability.

2. UNPACKING

Every Tannoy product and accessory is carefully inspected before packing. After unpacking, please
inspect your product to make sure no damage has occurred in transit. In the unlikely event of any
damage, would you please notify your dealer immediately and retain your shipping carton, as your
dealer may ask you to return the faulty unit to him for inspection.

Each CMS loudspeaker is packed in pairs and provided with the following accessories as standard;
C Ring, tile-bridge kit, grille, cut-out template, and paint mask. A plaster (mud) ring is also available
as an optional extra.

CMS

PAINTING

10

3. SAFETY NOTICES

Some regional construction codes require the use of a secondary method of securing loudspeakers
in ceiling to provide security of a back up support. A secondary support line should be attached from
the safety loop on the rear of the product to a source point on the ceiling. For PI models, the secondary
support line should be attached from the back of the driver chasis to a source point on the ceiling. Please 
consult the relevant construction codes in your region.

.

When using a power driver to install the product it is essential to use the correct torque level settings
to avoid over tightening and damage to the ceiling material or clamps.

Recommended torque setting: 1.5Nm

Tannoy will not be held responsible for any damages caused by the improper installation of these
loudspeakers.

Electrical Safety Notice: to comply with the standard UL1480, metal-clad flexible conduit (BX) is
required for connection to the terminal block for proper earth grounding.

In order to comply with UL regulations, the PI back-can must always be used with the CMS PI models.

PRODUCT FEATURE IDENTIFICATION

4

 

c

Summary of Contents for CMS 501 BM

Page 1: ...I L I N G M O N I T O R S Y S T E M S I N S T A L L A T I O N M A N U A L CMS REVISION DATE 2ND NOVEBER 2009 Tannoy United Kingdom T 00 44 0 1236 420199 E enquiries tannoy com Tannoy Deutschland T 00 49 180 1111 881 E anfragen tannoy com Tannoy France T 00 33 0 1 7036 7473 E ventes tannoy com TC Group Americas T 00 1 519 745 1158 E info tcgroup americas com Tannoy adopts a policy of continuous imp...

Page 2: ...cking After unpacking please inspect your product to make sure no damage has occurred in transit In the unlikely event of any damage would you please notify your dealer immediately and retain your shipping carton as your dealer may ask you to return the faulty unit to him for inspection Each CMS loudspeaker is packed in pairs and provided with the following accessories as standard C Ring tile brid...

Page 3: ...Screws for mounting wings Tuning Port r o t c e n n o C e p y T o r u E h c t i w S y r a t o R Conduit Knock out points Euro Type Plug Euro Type Connector 5 ACCESSORIES Each product is supplied with the following accessories as standard C Ring Tile bridge kit Note A tile bridge kit must always be used when installing into suspended ceiling tiles Grille Cut out template Paint Mask CMS Optional acc...

Page 4: ...saw or pad saw 2 Remove the ceiling tile from its frame and place it on a flat surface Mark the cut out area on the ceiling tile by tracing around the template provided 1 Go to section 7 for instructions on wiring and set up 6 2 MECHANICAL INSTALLATION GUIDE FOR SHEET ROCK PLASTER BOARD CEILINGS Slide the speaker assembly through the hole and turn the screws to extend the mounting wings Tighten th...

Page 5: ...w 3 Slide the speaker assembly through the hole and turn the screws to extend the mounting wings Tighten the screws until a firm grip is achieved 5 DO NOT OVERTIGHTEN Go to section 7 for instructions on wiring then return to point 5 below 4 CMS AN OPTIONAL PRE INSTALL BACK CAN IS AVAILABLE FOR ALL PI PRE INSTALL MODELS THIS BACK CAN IS DESIGNED TO BE PRE INSTALLED INTO NEWLY CONSTRUCTED NON SUSPEN...

Page 6: ...NSTALLATION BACK CAN PI MODELS ONLY Slide the speaker assembly through the hole and turn the screws to extend the mounting wings Tighten the screws until a firm grip is achieved 6 DO NOT OVERTIGHTEN CMS PTO Attach the conduit to the installed back can This can be attached in two ways 2 a You can use the clamp at the back of the pre install back can The product will accept a squeeze connector with ...

Page 7: ... tighten both screws on the cable clamp Use the rotary switch located on the front of the unit to select whether you wish to use the speaker in a low impedance or distributed line application 3 CMS 501 models TEMPLATE HOLE CUTOUT SIZE 190mm THE SPEAKER IS SUPPLIED IN LOW IMPEDANCE MODE NEVER CONNECT THE SPEAKER TO A 70 100 VOLT AMPLIFIER WHILE IT IS SET FOR LOW IMPEDANCE All CMS 501 models use a 3...

Page 8: ...back can Separate PI back can n a c k c a b I P e t a r a p e S n a c k c a b I P e t a r a p e S n a c k c a b I P e t a r a p e S I P l l a t s n I e r P n o i t p O Cable clamp plus up to 22mm squeeze connector p m a l c e l b a C s n o i t p o e l b a C plus up to 22mm squeeze connector Cable clamp plus up to 22mm squeeze connector Cable clamp plus up to 22mm squeeze connector 3 sets of horizo...

Page 9: ...s specified and intended Details of the Apparatus Tannoy Contractor Loudspeaker Model Numbers CMS 501 BM CMS 501 DC BM CMS 501 PI CMS 501 DC PI CMS 601 BM CMS 601 DC BM CMS 601 PI CMS 601 DC PI Applicable Standards EN 50081 1 Emission EN 50082 1 Immunity Electrical Safety EN 60065 Signed Position Engineering Director Professional Products Tannoy Professional Date 14 12 2005 For Tannoy Ltd CMS 11 W...

Page 10: ...18 19 NOTES NOTES CMS ...

Reviews: