background image

 

 

 

Technical Manual Contents 

 
 

 

 

Introduction

 – The Technical Manual explained  

Page 2

 

 

 

Technical Specs – 

Specifications relating to this particular item. 

Page 3

 

 

 

Instructions – 

For faultfinding, assembly & disassembly. 

Page 5

 

 

 

Circuit Diagrams –

 PCB Layouts 

Page 7 

 

 

Spares Drawing – 

All spare parts available to order for your 

loudspeaker as well as additional spares including the likes of spikes & 
feet. 

Page 12

 

 

 

Returns – 

Our field failure process explained and FFR returns form. 

Page 14

 

 

 

Warranty – 

Warranty information with contact info.  

Page 18

 

 

 

 
 
 
 
 
 
 

Page 1 

Summary of Contents for ARENA Highline TS300

Page 1: ...TS300 SERVICE MANUAL ...

Page 2: ...s For faultfinding assembly disassembly Page 5 Circuit Diagrams PCB Layouts Page 7 Spares Drawing All spare parts available to order for your loudspeaker as well as additional spares including the likes of spikes feet Page 12 Returns Our field failure process explained and FFR returns form Page 14 Warranty Warranty information with contact info Page 18 Page 1 ...

Page 3: ...ecs instructions for assembly disassembly faultfinding spares drawings parts lists as well as a detailed explanation of how to go about returning parts under warranty For further information regarding service or spares ordering please contact us directly TANNOY UK Tannoy Ltd Coatbridge North Lanarkshire ML5 4TF Scotland United Kingdom T 44 0 1236 420199 F 44 0 1236 428230 E mail enquiries tannoy c...

Page 4: ...ional Features Phase control crossover defeat switch for LFE operation soft limiting to avoid overload LF extension control Mains Voltage 120V Nominal AC 60Hz 230V Nominal AC 50Hz Mains Fuse 120V T3 15AL 250V 230V T1 6AL 250V Maximum Power Consumption 416VA Drive Unit Driver Type 1 x 250mm 10 Construction Enclosure Type Closed Box Enclosure Volume 20 0 LITRE 0 7 cu ft Enclosure Dimensions Excludin...

Page 5: ...eatures Phase control crossover defeat switch for LFE operation soft limiting to avoid overload LF extension control Mains Voltage 120V Nominal AC 60Hz 230V Nominal AC 50Hz Mains Fuse 120V T3 15AL 250V 230V T1 6AL 250V Maximum Power Consumption 600VA Drive Unit Driver Type 1 x 300mm 12 Construction Enclosure Type Closed Box Enclosure Volume 22 0 LITRE 0 78 cu ft Enclosure Dimensions Excluding Feet...

Page 6: ...lthough they may not be the source of the fault It is important to trace the cause of the problem as accurately as possible A fault heard on one source only CD or tape for instance is most unlikely to be a loudspeaker problem Loudspeakers do not in themselves generate hum hiss or rumble although high quality wide bandwidth loudspeakers may emphasise such problems Page 5 ...

Page 7: ...rvice required on the woofer you have to access via the grille this must be torn to be removed because of this we have included a grille with every replacement woofer If not please contact your Tannoy dealer or contact Tannoy direct enquires tannoy com 1 Tear the grille using a knife as shown in the diagram below 2 Once ripped pull the grille frame away from the cabinet 3 Once Grilled is removed y...

Page 8: ...Page 7 ...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...Page 12 ...

Page 13: ...Page 13 ...

Page 14: ...ction will be taken 3 We Cannot authorise the supply of spare parts free of charge or under warranty without complete information as to the nature of the failure 4 You Are required to hold all parts for which warranty claims have been made until instructed otherwise by Tannoy We may require to inspect failed parts at a later date Important Please note When claiming spare parts under warranty the p...

Page 15: ...omer Section Product Description Part Number Date Customer Distributor 20 Digit Product Barcode Number MANDATORY Detailed description of problem fault MANDATORY Insert pictures below Please be aware that we cannot accept field failure reports that do not have mandatory sections completed Page 15 ...

Page 16: ... wires Excessive amplifier power connection to low frequency or midrange amplifier in active system Leadout to coil joint failure solder Excessive amplifier power generating excessive temperatures which melts solder 300 C Coil rubbing Excessive continuous amplifier power resulting in separation of coil former Coil delamination due to excessive temperatures generated Improper replacement of diaphra...

Page 17: ...er and send you an Export Returns Authorization Form by fax or e mail 3 YOU Fill in all the relevant details in the form and send it to Tannoy before arranging shipment 4 WE On return of the completed form we will send you written approval to return the goods 5 YOU Arrange despatch of the goods to us ensuring the Returns Authorization Number is clearly quoted on all paperwork Please be sure to agr...

Page 18: ...Tannoy Ltd or its authorised Distributor or Service Agent will make the determination of the cause of failure based on physical inspection of the failed parts If you suspect a problem with your loudspeakers then in the first instance discuss it with your Tannoy Dealer The Dealer has the expertise and experience to help you troubleshoot the system and assess the situation If you continue to have pr...

Page 19: ...NOTES Page 19 ...

Page 20: ...NOTES Page 20 ...

Page 21: ......

Reviews: