44
Technical Specifications- Precision 8 iDP
System (Master & Slaves)
System
3-Way semi-active near field monitor
Frequency Response
(1)
43Hz – 51kHz (+/- 2dB)
Max. SPL (@ 1m)
(2)
120dB (continuous)
Dispersion (-6dB)
90 degrees
Crossover Frequency
1.7kHz (DSP generated) & 16kHz (passive)
Drive units
200mm (8") Tannoy Dual Concentric™ constant directivity driver with
multiple fibre paper pulp cone.
25mm (1") titanium dome Wideband™ SuperTweeter™,
Neodymium magnet system
Cabinet LF Alignment
Optimised bass reflex loaded
Dimensions (H x W x D)
440mm x 272mm x 369mm (17
3
/
8
” x 10
3
/
4
” x 14
1
/
2
”)
Cabinet Construction
MDF cabinet and front baffle, tongue and groove front and back
Black cabinet grey painted baffle with brushed aluminium inlay
Black anodized aluminum back plate
Total weight
17 kg (37.4lbs)
Electronic System
Mains Voltage
100 to 240Vac, 50 – 60Hz (auto – select)
Power Consumption
45W @
1
/
8
full power (IEC 6065)
Amplifier
Bass/midrange – 200 Watts Class D
Tweeter & SuperTweeter™ 200 Watts Class D
System Sample Rates:
Internal
96 kHz (except when slaved to digital input or word clock input)
External
96, 88.2, 64, 48, 44.1 or 32 kHz (optional 192kHz)
Digital Section (Master only):
I/O connectors
XLR (2 channels AES/EBU in). 3 x RJ45 proprietary TC LINK
Formats
AES\EBU
Word clock
Input BNC, 75 , 0.6 to 10 Vpp
Display
2 x 16 character dot matrix
Operation
Menu system / four buttons
Analogue Section (Master only):
Input connectors
XLR balanced (pin 2+, pin 3-)
Impedance
10/3 k (balanced/unbalanced)
Selectable Full Scale Input Level
+9, +15, +21, +27 dBu
Dynamic Range
> 113 dB typ. (unweighted), BW: 20-20kHz
THD+N
< -105 dB typ. @ 1 kHz, -3 dBFS
Cross-talk
< -120 dB, 20 Hz to 20 kHz
A to D Conversion
24 bit (Dual bit delta sigma sampling at 4.1/5.6/6.1/6.1MHz)
Slaves Only:
I/O connector’s
2-x RJ45 proprietary TC LINK
The typical listening distance for
Precision 8 iDP
is 1.3 -2.8 m
The typical room size for
Precision 8 iDP
is 50-100 m3
NOTES
(1)
+/- 3 dB, measured at 1m in an anechoic chamber.
(2
)
Peak SPL at mix position for 1 pair driven.
Tannoy operates a policy of continuous research and development. The introduction of new materials or manufacturing methods will always equal or exceed the published
specifications which Tannoy reserve the right to alter without prior notice. Please verify the latest specifications when dealing with critical applications.
A C T I V E S T U D I O M O N I T O R S
Summary of Contents for ACTIVE STUDIO MONITORS
Page 1: ...A C T I V E S T U D I O M O N I T O R S OWNERS M A N U A L ...
Page 2: ......
Page 55: ......