background image

ATEK Access Technologies

10025 Valley View Road, Ste. 190 
Eden Prairie, MN 55344 U.S.A. 

PH:   1.800.523.6996 
FAX:  1.800.589.3705
 

+1.218.829.9797

www.atekaccess.com

223-0176-001  Rev. D  4/21

©2021 ATEK Access Technologies, LLC. All Rights Reserved. TankScan images and marketing materials are protected by various patents, copyrights 

and/or trademarks. ATEK assumes no responsibility for any errors which may appear in this document, reserves the right to change devices or 

specifications detailed herein at any time without notice, and does not make any commitment to update the information contained herein. No licenses to 

patents or other intellectual property of ATEK are granted by the Company in connection with the sale of TankScan products, expressly or by implication.

TSU1000M Remote Sensor

Setup Instructions

If tank is metal, attach mounting base onto tank and push down until all 
four feet are touching. Tighten wing nuts until mounting base no longer 
wobbles. This allows mounting base to adapt to different tank shapes.

If tank is plastic or non-magnetic, clean area on tank mounting base will 
attach to. Remove backing from VHB tape feet and attach mounting base 
onto tank. Press down firmly on base for a few seconds to ensure good 
adhesion.  

Screw TSU monitor into mounting base.

Mount the TSU Monitor

6

7

8

9

10

11

Screw sensor into tank port or stilling tube until tight.
•  Seal pipe threads of sensor using product appropriate for this  

 

 

application prior to tightening into tank port.

Connect 90° female end of sensor cable into connector on top of sensor 
and finger tighten only.

Connect straight male end of sensor cable into connector on TSU monitor 
and finger tighten only.

Locate triangle indicator on outside of TSU monitor. Using magnetic end 
of screwdriver, swipe along rim above indicator until a beep is heard.

Use included zip ties to secure sensor cable and prevent cable from 
hanging and reduce slack.

Call TankScan Technical Support after swiping monitor to complete 
monitor setup.

Note: Step 11 must be completed for the unit to function.

Startup TSU Monitor

5

4

9

7

8

4

TankScan 

Technical Support 

877-847-7226

[email protected]

Reviews: