![TankScan TSM1000 Setup Instructions Download Page 2](http://html.mh-extra.com/html/tankscan/tsm1000/tsm1000_setup-instructions_817707002.webp)
ATEK Access Technologies
10025 Valley View Road, Ste. 190
Eden Prairie, MN 55344 U.S.A.
PH: 1.800.523.6996
FAX: 1.800.589.3705
+1.218.829.9797
www.atekaccess.com
©2021 ATEK Access Technologies, LLC. All Rights Reserved. TankScan images and marketing materials are protected by various patents, copyrights
and/or trademarks. ATEK assumes no responsibility for any errors which may appear in this document, reserves the right to change devices or
specifications detailed herein at any time without notice, and does not make any commitment to update the information contained herein. No licenses to
patents or other intellectual property of ATEK are granted by the Company in connection with the sale of TankScan products, expressly or by implication.
223-0191-000 Rev. B
6
/21
WARNING
: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
12
11
7
For monitors installed on risers greater than 3” long, a PWG is required to
prevent probe wire from contacting riser. Refer to TankScan Probe Wire
Guard Installation Guide or tankscan.com/support.
NOTE
:
Return to these setup instructions to complete monitor
installation after Probe Wire Guard installation.
If PWG is required but not provided as a field-installable kit, contact
TankScan Technical Support to order PWG Field Install Kit before proceeding.
If PWG is not required, then proceed to step 8.
Determine if Probe Wire Guard (PWG) is Needed
8
9
Lower probe wire with weight gently through tank port into tank. Position
monitor over tank port and hand tighten until secure.
Seal pipe threads of monitor using product appropriate for this application
prior to tightening into tank port. Remote battery pack cable can be removed
for ease of installation then plugged in once monitor is fully mounted.
Connect battery cable to remote battery pack and mount remote battery
pack at base of tank such that the battery cable is coming out bottom of
remote battery pack housing. If mounting remote battery pack to a plastic
tank, apply hook and loop fastener strips to edges of magnet face of remote
battery pack.
Mount TSM Monitor to Tank
10
Test monitor by swiping magnet end of supplied screwdriver along cover’s
rim above triangle indicator on housing base until a beep is heard. Monitor
will take a level reading and then report to ATEK Intelligence Platform (AIP).
A second single beep will occur once monitor has finished reporting its
level measurement.
If monitor has been pre-provisioned, then confirm reading is correct on AIP
or optionally call TankScan Technical Support, to finish or confirm reading.
NOTE:
Step 12 must be completed for monitor to function properly.
Test Setup
TankScan Technical Support
877-847-7226
7
TSM1000 Tank Monitor
with
Remote Battery Setup Instructions
10
12
Cellular
Contains FCC ID: MCQ-XB3M1
Contains IC: 1846A-XB3M1
Rf
Contains FCC ID: MCQ-XBEE3
Contains IC: MCQ-XBEE3
Operation is subject to the following
2 conditions:
1. This device may not cause harmful
interference and
2. This device must accept any interference
received, including interference that may
cause undesirable operation.