 Carbon Monoxide Poisoning Prevention 

Excessively high winds may cause the exhaust to back-flow. During high wind conditions, please 
stop using the heater or it may lead to a dangerous situation. 
 

 

In  confined  spaces  the  burning  of  gas  consumes  large  amounts  of  air  and  produces  gases 
which  contain  certain  amounts  of  carbon  monoxide.  Thus,  the  heater  must  be  fixed  in  a 
ventilated location. (See combustion air requirements below)  

 

As this water heater is a flue type, if mounted inside a structure, a flue must be installed to 
drain the waste gas out of the room. (See combustion air requirements below)  

 

NG  users  must  pay  attention  to  the  back-fire  phenomenon  when  the  gas  pressure  is 
insufficient. This causes carbon deposits in the burner to increase and affects the normal use 
of the heater. In such case, should the flame turn from blue to yellow, the amount of carbon 
monoxide would increase. Stop using the heater and contact the gas company or the service 
center. 

 

The heater must always be installed vertically. 
 

 Prevent Eye injury. 

 

Keep  eyes  away  from  the flame check window at a  minimum  safety distance  of 12 inches 
during  ignition.  If  the  first  attempt  of  ignition  fails,  wait  10-20  seconds  before  the  next 
attempt for the gasses to clear. 

 Prevent no-water “dry Burning” of the Heater 

   After  each  shower,  make  sure  that  the  flame  is  extinguished  when  the  valve  is  closed.  If  the 

flame  still  exists  after  the  water  valve  is  closed,  something  must  be  wrong  with  the  heater. 
Switch  off  the  gas  valve  immediately  and  contact  the  service  center.  Otherwise  the  heater 
may be damaged by overheating and then may cause an accidental fire. 

 Freeze Prevention 

 

Under  low  temperature  situations,  drain  the  water  remaining  in  the  heater  after  each  use 
completely.  Otherwise  the  water  may  freeze  and  expand  which  may  internally  damage  the 
heater. (See freeze warning below)  

 

 

Reduce the Chance of Encrustation (mineral and sediment deposits) 

We recommend a pre-filtration device be installed on the incoming water supply line to keep 
the interior of the heater clean. 
 
 

 

Dealing with Abnormal Conditions 

 

Stop  the  heater  when  there  is  strong  adverse  wind  blowing  which  may  cause  the  heater  to 
become inoperable. 

 

In  case  of  abnormal  burning  (e.g.  fire  back,  fire  off,  yellow  flame  or  black  smoke,  etc.), 
unusual smell, noise or other abnormal matters, keep calm and turn off the gas valve and the 
heater switch. Then contact the service center or the gas dealer. 

 
REMARKS:  Since  the  heater  has  multiple  safety  protection  functions  it  may  turn  off  when  a 
problem is encountered, please refer to the "trouble shooting" table to solve the problem before 
using again. 
 

 

Replacing the D cells 

 

After the batteries are used a period of time (about 6 months under normal use), the heater 
wont ignite. Simply replace these batteries. 

 

To replace the batteries please see above "cell installation" (fig. 8) 

 

 

Summary of Contents for EZ-101

Page 1: ...Fully automatic Gas tankless Water Heater USER S MANUAL FOR MODEL EZ 101 ISO9001 certified ...

Page 2: ...sh and the heater will return to stand by mode Independent control of water flow and gas flow makes it easy to regulate water temperature 2 Innovative design Ultra thin design attractive shape and convenient to install Advanced energy saving combustion technology greatly promotes burning efficiency No standing pilot for more energy savings Low water pressure 2 9 Psi ignition With a three position ...

Page 3: ...let control Exhaust method Flue Ignition method Water operated Automatic Ignition Power 2 D Cells Not Included Safety Devices Flame out Protection A 20 minute timer etc Suitable Water Pressure 8 to 100 Psi Connector specification Gas inlet G1 2 inch USA Pipe thread Cold water inlet G1 2 inch USA Pipe thread Hot water outlet G1 2 inch USA pipe thread Notice please see the label for the actual rated...

Page 4: ...h 4 7 inches BEFORE INSTALLATION Before installation contact your local gas dealer or gas management department directly or indirectly for a qualified engineer s opinion because improper installation is dangerous to safety or may even endanger your life ...

Page 5: ...ion air requirements below The flame display window of the water heater should be located in a position where the flame window can be easily viewed at eye level approximately five feet above the floor No wires or electric equipment shall be put above the water heater The heater should be kept at least 15 inches away from electronics horizontally The heater should be kept well away from any flammab...

Page 6: ...ing the gas pipes check the connections with soap suds for gas leakage Water Inlet connection It s best to use proper tubing flex hose or rigid pipe to connect the water inlet A water shut off valve should be installed before the water inlet fitting Fig 7 Note There is a screen type filter inside the water inlet nipple do not lose it during installation Hot Water Outlet connection If connecting th...

Page 7: ...of the flue shall have a minimum of 1 down inclination and there shall be a inch hole at the bottom of the vertical part of the flue outside the room for the purpose of draining water condensation or rain droplets The outlet of the flue must have a windproof cap which should not be clogged Installation method Drill proper holes in the wall according to the dimensions of the heater and install a ce...

Page 8: ...llow the water to drain from the heater You may also blow a slight flow of compressed air to clear the internal components of water 2 Flame level Control In hot weather and higher ground water temperatures you may wish to turn the flame level switch winter summer switch to the position of warm and only one burner will ignite In cold weather and colder ground water temperatures turn the flame level...

Page 9: ...er valve in case of water leakage Do not pile inflammables explosives or volatile materials anywhere near the heater Fig 13 Do not place inflammables like towels or clothing onto the waste gas exhaust outlet or the air inlet Fig 14 For LPG users NEVER tilt or invert the tank otherwise the liquid in the gas cylinder may flow into the heater and cause an accidental fire or explosion ...

Page 10: ...flame is extinguished when the valve is closed If the flame still exists after the water valve is closed something must be wrong with the heater Switch off the gas valve immediately and contact the service center Otherwise the heater may be damaged by overheating and then may cause an accidental fire Freeze Prevention Under low temperature situations drain the water remaining in the heater after e...

Page 11: ...e flame turns from blue to yellow with black smoke stop using and contact the service center immediately for help Every 6 months contact qualified professionals to check whether the heat exchanger and burner are clogged Every 6 months it may be necessary to flush the heater internally Always keep the cover of the heater clean FREEZE WARNING This water heater holds cold water in its heat exchanger ...

Page 12: ...losure Each opening must have a minimum free area of one square inch per 1000 Btu hr if all air is taken from inside the building 2000 Btu hr if all air is taken from the outside by horizontal ducts 4000 Btu hr if all air is taken from the outside by direct openings or vertical ducts Or the confined space must be provided with one permanent opening or duct that is within 12 inches of the ceiling o...

Page 13: ......

Reviews: