22
| CE CES CERO SERIES
WWW.STIEBEL-ELTRON-USA.COM
INSTALLATION
TEChNICAL DATA
11.5.9 CE/CES/CERO 120, CE/CES/CERO 144 400 V & 480 V Delta wiring diagram (page 1)
This diagram is valid for: CE/CES/CERO 120 400/480 V, CE/CES/CERO 144 400/480 V
CE Wiring Diagram
17 West St., W. Hatfield, MA 01088
|
800.582.8423
|
413.247.3380
|
fax 413.247.3369
|
info
@
stiebel-eltron-usa.com
|
www.stiebel-eltron-usa.com
13
CE 108-144, 480 V Delta (Page 1)
This diagram is valid for CE 108 480 V, CE 120 480 V, & CE 144 480 V.
A1
Control board 1
A2
Control board 2
B1
Thermistor 1
B2
Thermistor 2
D1
Delay timer
F1-F12
Fuse
FS1
Flow sensor 1
FS2
Flow sensor 2
G1
Main power light
G2
On/off power light
P1
Low pressure switch
R1-R24
Resistance element
S1
On/off switch
S2
Temperature toggle switch
T1-T24
Thermostat
TR1-TR12
Triac
TX1
Transformer
X0
Main terminal block
X1
Ground terminal
X2
Secondary terminal block 1
X3
Secondary terminal block 2
X4
Fuse block
X5
Thermostat block 1
X6
Element block 1
X7
Element block 2
X8
Thermostat block 2
X9
Triac block
X10
Transformer terminal block 1
X11
Transformer terminal block 2
Delta Configuration
L
1
E
3
E
1
E
2
L
2
L
3
HX Flow Layout
Approved: Wes Palmer 01/17/20
CE-108-144-480D