Tanita TBF-621 Instruction Manual Download Page 7

Turn the unit on.

Select Adult
or Child.

Store in memory.

Select Male
or Female.

Female

Male

Store in memory.

Specify Height.

Store in memory.

Confirmed data will flash for three seconds.

Select “1 or 2.”

Store in memory.

Setting and Storing Data in Memory

The TBF-621 can be operated only if data has been preprogrammed into one of the two
Personal keys. Once programmed, tapping a Personal key turns the monitor on. The unit has
an automatic shut-down function. If you do not step on the platform after pressing a
Personal key, the unit will automatically shut off in about 30 seconds.

The TBF-621 is intended for use by adults and children who have moderately active to
inactive lifestyles.

The TBF-621 is not intended for use by persons with athletic body types. (See p.1 for Tanita’s
definition of “athlete.”)

1. Turn on the Power

When programming data, use the Orange Set button to turn the unit on. The register
numbers (“1 or 2”) will appear and the display will flash.

2. Select a Personal Key

Use the Green Arrow button to select a Personal key, then press the Orange Set button.

3. Select Adult or Child

Use the Green Arrow button to specify Adult or Child, then press the Orange Set button.

Adult = age 18 or older, who has moderately active to inactive lifestyle.
Child = up to the age of 18, over 3' 4" (102 cm), who has moderately active 

to inactive lifestyle.

4. Select Male or Female

Use the Green Arrow button to select Male or Female, then press the Orange Set button.
(   ) Male   (   ) Female

5. Specify the Height

Use the Green Arrow button to specify Height. Then press the Orange Set button.

The display will flash all data (Adult/Child, Male/Female and Height) for three seconds to
confirm the programming. The power will automatically turn off.

Getting Accurate Readings

To get the most accurate absolute values, readings should be taken without clothing and
under consistent conditions of hydration. If you do not undress, always remove your socks 
or stockings, and be sure the soles of your feet are clean before stepping on the measuring
platform. Stand erect on the platform.

Note:

An accurate reading will not be possible if the soles of your feet are not clean, or if your knees are bent

or you are in a sitting position.

It is best to take readings at the same time of day. Remember to wait about three hours after
rising, eating, or hard exercise before taking measurements. While readings taken under other
conditions may not have the same absolute values, they are accurate for determining the
percentage of change as long as the readings are taken in a consistent manner. To monitor
progress, compare weight and body fat percentage taken under the same conditions over a
period of time.

5

Summary of Contents for TBF-621

Page 1: ...TBF 621BODYFAT MONITOR SCALE Instruction Manual Read this Instruction Manual carefully and keep it for future reference ...

Page 2: ...ide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harm...

Page 3: ...rs per week and who has a resting heart rate of approximately 60 beats per minute or less Tanita s athlete definition includes lifetime of fitness individuals who have been fit for years but currently exercise less than 10 hours per week Tanita s athlete definition does not include enthusiastic beginners who are making a real commitment to exercising at least 10 hours per week but whose bodies hav...

Page 4: ... the body can be accurately estimated by measuring the impedance The signal used is very low making it safe and imperceptible The illustration on the left show how the signal travels through the body Body Fat Percentage Fluctuations in a Day Hydration levels in the body may affect body fat readings Readings are usually highest in the early waking hours since the body tends to be dehydrated after a...

Page 5: ...equations derived from large multi ethnic population studies to predict body composition Readings taken with Tanita s TBF 621 correlate highly with both DEXA Tanita s reference model and Hydrodensitometry Features and Functions Components Measuring Platform This Instruction Manual Support Feet 4 Educational Booklet Batteries 4 Getting Started Workbook Measuring Platform 1 Display Screen 2 Orange S...

Page 6: ...er automatically in the following cases If you interrupt the measurement process The power will shut down automatically within 10 to 20 seconds depending upon the type of operation If an extraordinary weight is applied to the platform If you make a mistake during measurement or a key or button operation After you have completed the measuring process Note If the power shuts off unexpectedly repeat ...

Page 7: ...inactive lifestyle Child up to the age of 18 over 3 4 102 cm who has moderately active to inactive lifestyle 4 Select Male or Female Use the Green Arrow button to select Male or Female then press the Orange Set button Male Female 5 Specify the Height Use the Green Arrow button to specify Height Then press the Orange Set button The display will flash all data Adult Child Male Female and Height for ...

Page 8: ...of body fat percentage and body weight will be displayed alternately at two second intervals If you remain on the platform the display will continue for about 30 seconds and then the power will automatically turn off If you step off the platform the alternating display of body fat percentage and body weight will be repeated three times and then the power will automatically turn off Multiple Users ...

Page 9: ...is pressed or the display shows and goes off when a Personal key is pressed No data Adult Child Male Female or Height has been stored in the memory of that Personal key The body fat percentage reading does not appear after the weight is measured Vibration will interfere with the fat percentage reading Be sure to stand erect and still on the measuring platform Do not bend your knees Be sure that sh...

Page 10: ...son is authorized to change the terms of this warranty If Product Is Defective or Needs Repair Do not return this product to the place of purchase doing so may delay the processing of your warranty claim Call Tanita at1 800 TANITA 8 to receive a Return Authorization Number before returning this product Include 12 50 for handling return postage and insurance to the facility listed below Proof of pu...

Page 11: ...lly Sur Seine Tel 01 5524 9999 Fax 01 5524 9868 Tanita Health Equipment H K Ltd Unit 301 303 3 F Wing On Plaza 62 Mody Road Tsimshatsui East Kowloon Hong Kong Tel 852 2838 7111 Fax 852 2838 8667 Tanita Corporation of Japan 14 2 1 Chome Maeno Cho Itabashi Ku Tokyo Japan 174 8630 Tel 03 3968 2123 Fax 03 3967 3766 ISO 9001 Certified Tanita Corporation of America Inc 2625 S Clearbrook Drive Arlington ...

Reviews: